Literature DB >> 2717142

Refractive errors induced by displacement of intraocular lenses within the pseudophakic eye.

D A Atchison1.   

Abstract

Simple methods were developed to estimate refractive errors when intraocular lenses are not fitted optimally within pseudophakic eyes. The accuracy of these methods was determined by comparing results obtained with them to results obtained by raytracing through a model eye. Accuracy was good for longitudinal displacement and tilting, and reasonable for transverse displacement. Refractive errors are related linearly to the magnitude of the longitudinal displacement, and are related to the square of the magnitude of tilt or transverse displacement. The refractive error upon transverse displacement is quadratically dependent upon lens shape.

Mesh:

Year:  1989        PMID: 2717142     DOI: 10.1097/00006324-198903000-00003

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  6 in total

1.  Visual simulation of retinal images through a decentered monofocal and a refractive multifocal intraocular lens.

Authors:  Kazuno Negishi; Kazuhiko Ohnuma; Takashi Ikeda; Toru Noda
Journal:  Jpn J Ophthalmol       Date:  2005 Jul-Aug       Impact factor: 2.447

2.  Comparison of the keratometric corneal astigmatism and refractive astigmatism after phacoemulsification and foldable intraocular lens implantation.

Authors:  Ali Sharifi; Leila Sharifi; Afsaneh Morteza
Journal:  Int Ophthalmol       Date:  2012-06-09       Impact factor: 2.031

3.  Comparison of Maximum Stretch Forces between Femtosecond Laser-Assisted Capsulotomy and Continuous Curvilinear Capsulorhexis.

Authors:  Mari Takagi; Takashi Kojima; Kei Ichikawa; Yoshiki Tanaka; Yukihito Kato; Rie Horai; Akeno Tamaoki; Kazuo Ichikawa
Journal:  J Ophthalmol       Date:  2017-01-22       Impact factor: 1.909

4.  Keratoconic eyes with stable corneal tomography could benefit more from custom intraocular lens design than normal eyes.

Authors:  Simon Schröder; Timo Eppig; Weidi Liu; Jens Schrecker; Achim Langenbucher
Journal:  Sci Rep       Date:  2019-03-05       Impact factor: 4.379

5.  Determining the Theoretical Effective Lens Position of Thick Intraocular Lenses for Machine Learning-Based IOL Power Calculation and Simulation.

Authors:  Damien Gatinel; Guillaume Debellemanière; Alain Saad; Mathieu Dubois; Radhika Rampat
Journal:  Transl Vis Sci Technol       Date:  2021-04-01       Impact factor: 3.283

Review 6.  New technology update: femtosecond laser in cataract surgery.

Authors:  Zoltan Z Nagy
Journal:  Clin Ophthalmol       Date:  2014-06-18
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.