Literature DB >> 27170594

High recurrence of device-related adverse events following transvenous lead extraction procedure in patients with cardiac resynchronization devices.

François Regoli1, Maria Grazia Bongiorni2, Roberto Rordorf3, Matteo Santamaria4, Caterine Klersy5, Luca Segreti2, Valentina De Regibus3, Tiziano Moccetti6, Giulio Conte6, Maria Luce Caputo6, Angelo Auricchio6.   

Abstract

INTRODUCTION: Little is known about the clinical outcome and recurring system-related adverse events (SAE) in cardiac resynchronization therapy (CRT) patients after transvenous lead extraction (TLE). METHODS AND
RESULTS: From January 2009 to June 2014, 256 consecutive CRT patients (mean age 68.3 ± 11.6 years, 216 male, 88% in New York Heart Association class II-IV, ejection fraction 35.1 ± 10.8%) were treated at four European institutions with TLE. Indications for TLE included systemic (18%) or local (45%) infection, system malfunction (34%), or other (3%). Demographic, clinical, TLE procedural, and follow-up data were collected retrospectively. Adverse events (AE) were considered as death from any cause, cardiovascular hospitalization, and SAE (SAE included pocket and/or systemic infection, lead malfunction, or pocket haematoma requiring revision). Complete removal was achieved for 609 out of 614 leads (99.2%) by using either manual traction (28%), mechanical (52%) or laser (20%) sheaths. Over a median follow-up of 21 (interquartile range 12-29) months, cumulative incidences of any AE and SAE were 53.9% and 21.1%, respectively. Recurring system malfunction occurred in 23 patients (9.0%), infection in 16 patients (6.2%), and pocket haematoma requiring revision in 15 patients (5.9%). Oral anticoagulation therapy was an independent predictor of both any AE [hazard ratio (HR) 2.09, 95% confidence interval (CI) 1.35-3.22, P = 0.001] and SAE (HR 2.38, 95% CI 1.21-4.68, P = 0.012) after TLE.
CONCLUSIONS: Even though TLE is safe and effective to treat CRT patients, a high burden of recurring SAE after TLE was observed at mid-term follow-up. Careful evaluation of both patient characteristics as well as implantation strategy is suggested when indicating TLE in a CRT patient, particularly in patients receiving oral anticoagulation therapy.
© 2016 The Authors. European Journal of Heart Failure © 2016 European Society of Cardiology.

Entities:  

Keywords:  Cardiac resynchronization therapy; Device-related adverse events; Lead management; Transvenous lead extraction

Mesh:

Year:  2016        PMID: 27170594     DOI: 10.1002/ejhf.558

Source DB:  PubMed          Journal:  Eur J Heart Fail        ISSN: 1388-9842            Impact factor:   15.534


  2 in total

1.  Transvenous Lead Extraction in Patients with Cardiac Implantable Device: The Impact of Systemic and Local Infection on Clinical Outcomes-An ESC-EHRA ELECTRa (European Lead Extraction Controlled) Registry Substudy.

Authors:  Igor Diemberger; Luca Segreti; Christopher A Rinaldi; Jesper Hastrup Svendsen; Andrzej Kutarski; Arwa Younis; Cécile Laroche; Christophe Leclercq; Barbara Małecka; Przemyslaw Mitkowski; Maria Grazia Bongiorni
Journal:  Biology (Basel)       Date:  2022-04-18

2.  Assessing long-term survival and hospitalization following transvenous lead extraction in patients with cardiac resynchronization therapy devices: A propensity score-matched analysis.

Authors:  Vishal S Mehta; Hugh O'Brien; Mark K Elliott; Baldeep S Sidhu; Justin Gould; Anoop K Shetty; Steven Niederer; Christopher A Rinaldi
Journal:  Heart Rhythm O2       Date:  2021-10-30
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.