Literature DB >> 27170220

Improved image-quality consistency in coronary CT angiography using a test-bolus-based individually tailored contrast medium injection protocol.

X Zhu1, Y Zhu1, W Liu1, G Yang2, Z Su3, L Tang4, Y Xu5.   

Abstract

AIM: To develop and validate a test bolus (TB)-based quantitative model to create an individualised contrast medium injection protocol for use at coronary computed tomography angiography (CCTA) to improve patient-to-patient uniformity of intracoronary attenuation.
MATERIALS AND METHODS: In the model-building phase, 175 patients who underwent CCTA using a traditional contrast medium injection protocol were recruited. A personalised injection equation was proposed according to the relationship between aortic enhancement and the haemodynamic parameters obtained from the TB. In the model-validation phase, a target aortic enhancement of 350 HU was set. Two hundred and fifteen additional CCTA examinations were performed using the proposed personalised injection model. Comparisons of inter-individual variability between the traditional and the proposed personalised injection protocol were performed.
RESULTS: In the model-building phase, a high positive correlation between aortic enhancement and the haemodynamic parameters obtained from the TB was found. As a result, a personalised injection equation was determined using linear regression. In the model-validation phase, the average aortic enhancement was 350.5 HU, without significant differences from the preset level. Using the TB-based personalised injection protocol, inter-individual variability of aortic enhancement was significantly reduced (71.8 versus 38.9 HU, p<0.001) and patients who were scanned at 100 kVp had a reduction in the average contrast medium flow rate from 4.1 to 3.2 ml/s (p<0.001).
CONCLUSIONS: The proposed TB-based injection protocol can achieve a desired preset and stable aortic enhancement.
Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27170220     DOI: 10.1016/j.crad.2016.04.001

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  2 in total

1.  Coronary angiography using second-generation dual source computed tomography: Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article.

Authors:  Xiaomei Zhu; Yusheng Yu; Dinghu Xu; Hong Zhang; Lijun Tang
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

2.  Machine learning-based prediction of insufficient contrast enhancement in coronary computed tomography angiography.

Authors:  H A Marquering; R N Planken; R R Lopes; T P W van den Boogert; N H J Lobe; T A Verwest; J P S Henriques
Journal:  Eur Radiol       Date:  2022-06-16       Impact factor: 7.034

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.