Impact of iterative metal artifact reduction on diagnostic image quality in patients with dental hardware.

Jakob Weiß1, Christoph Schabel1, Malte Bongers1, Rainer Raupach2, Stephan Clasen1, Mike Notohamiprodjo1, Konstantin Nikolaou1, Fabian Bamberg1.   

Abstract

Background Metal artifacts often impair diagnostic accuracy in computed tomography (CT) imaging. Therefore, effective and workflow implemented metal artifact reduction algorithms are crucial to gain higher diagnostic image quality in patients with metallic hardware. Purpose To assess the clinical performance of a novel iterative metal artifact reduction (iMAR) algorithm for CT in patients with dental fillings. Material and Methods Thirty consecutive patients scheduled for CT imaging and dental fillings were included in the analysis. All patients underwent CT imaging using a second generation dual-source CT scanner (120 kV single-energy; 100/Sn140 kV in dual-energy, 219 mAs, gantry rotation time 0.28-1/s, collimation 0.6 mm) as part of their clinical work-up. Post-processing included standard kernel (B49) and an iterative MAR algorithm. Image quality and diagnostic value were assessed qualitatively (Likert scale) and quantitatively (HU ± SD) by two reviewers independently. Results All 30 patients were included in the analysis, with equal reconstruction times for iMAR and standard reconstruction (17 s ± 0.5 vs. 19 s ± 0.5; P > 0.05). Visual image quality was significantly higher for iMAR as compared with standard reconstruction (3.8 ± 0.5 vs. 2.6 ± 0.5; P < 0.0001, respectively) and showed improved evaluation of adjacent anatomical structures. Similarly, HU-based measurements of degree of artifacts were significantly lower in the iMAR reconstructions as compared with the standard reconstruction (0.9 ± 1.6 vs. -20 ± 47; P < 0.05, respectively). Conclusion The tested iterative, raw-data based reconstruction MAR algorithm allows for a significant reduction of metal artifacts and improved evaluation of adjacent anatomical structures in the head and neck area in patients with dental hardware.

Entities:  

Keywords:  Head/neck; artifacts; computed tomography (CT); image manipulation/reconstruction

Mesh:

Substances:

Year:  2016        PMID: 27166346     DOI: 10.1177/0284185116646144

Source DB:  PubMed          Journal:  Acta Radiol        ISSN: 0284-1851            Impact factor:   1.990


  15 in total

1.  Follow-up CT and CT angiography after intracranial aneurysm clipping and coiling-improved image quality by iterative metal artifact reduction.

Authors:  Georg Bier; Malte Niklas Bongers; Johann-Martin Hempel; Anja Örgel; Till-Karsten Hauser; Ulrike Ernemann; Florian Hennersdorf
Journal:  Neuroradiology       Date:  2017-06-03       Impact factor: 2.804

2.  Iterative algorithms for metal artifact reduction in children with orthopedic prostheses: preliminary results.

Authors:  Seema Toso; Meryle Laurent; Elise Dupuis Lozeron; Pauline Brindel; Marirosa Cristallo Lacalamita; Sylviane Hanquinet
Journal:  Pediatr Radiol       Date:  2018-07-28

3.  Imaging artifacts of Onyx and PHIL on conventional CT, cone-beam CT and MRI in an animal model.

Authors:  Dominik F Vollherbst; Ruth Otto; Thuy Do; Hans U Kauczor; Martin Bendszus; Christof M Sommer; Markus A Möhlenbruch
Journal:  Interv Neuroradiol       Date:  2018-07-04       Impact factor: 1.610

4.  Clinical evaluation of the iterative metal artefact reduction algorithm for post-operative CT examination after maxillofacial surgery.

Authors:  Arsany Hakim; Johannes Slotboom; Olivier Lieger; Fabian Schlittler; Roland Giger; Chantal Michel; Roland Wiest; Franca Wagner
Journal:  Dentomaxillofac Radiol       Date:  2017-03-07       Impact factor: 2.419

5.  Diagnostic Value of Model-Based Iterative Reconstruction Combined with a Metal Artifact Reduction Algorithm during CT of the Oral Cavity.

Authors:  Y Kubo; K Ito; M Sone; H Nagasawa; Y Onishi; N Umakoshi; T Hasegawa; T Akimoto; M Kusumoto
Journal:  AJNR Am J Neuroradiol       Date:  2020-09-24       Impact factor: 3.825

6.  Value of CT iterative metal artifact reduction in PET/CT-clinical evaluation in 100 patients.

Authors:  Christian Philipp Reinert; Christian la Fougère; Konstantin Nikolaou; Christina Pfannenberg; Sergios Gatidis
Journal:  Br J Radiol       Date:  2019-01-14       Impact factor: 3.039

7.  Imaging Artifacts of Liquid Embolic Agents on Conventional CT in an Experimental in Vitro Model.

Authors:  N Schmitt; R O Floca; D Paech; R A El Shafie; F Seker; M Bendszus; M A Möhlenbruch; D F Vollherbst
Journal:  AJNR Am J Neuroradiol       Date:  2020-11-19       Impact factor: 3.825

8.  CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection.

Authors:  Felix E Diehn; Gregory J Michalak; David R DeLone; Amy L Kotsenas; E Paul Lindell; Norbert G Campeau; Ahmed F Halaweish; Cynthia H McCollough; Joel G Fletcher
Journal:  Acta Radiol Open       Date:  2017-11-26

9.  Secure Screw Placement in Management of Acetabular Fractures Using the Suprapectineal Quadrilateral Buttress Plate.

Authors:  R J Egli; M J B Keel; J L Cullmann; J D Bastian
Journal:  Biomed Res Int       Date:  2017-06-15       Impact factor: 3.411

10.  Comparison of quantitative measurements of four manufacturer's metal artifact reduction techniques for CT imaging with a self-made acrylic phantom.

Authors:  Ryan Chou; Hung-Yi Chi; Yi-Hung Lin; Liu-Kuo Ying; Yu-Ju Chao; Cheng-Hsun Lin
Journal:  Technol Health Care       Date:  2020       Impact factor: 1.285