Literature DB >> 27164045

Vector velocity volume flow estimation: Sources of error and corrections applied for arteriovenous fistulas.

Jonas Jensen1, Jacob Bjerring Olesen2, Matthias Bo Stuart2, Peter Møller Hansen3, Michael Bachmann Nielsen4, Jørgen Arendt Jensen2.   

Abstract

A method for vector velocity volume flow estimation is presented, along with an investigation of its sources of error and correction of actual volume flow measurements. Volume flow errors are quantified theoretically by numerical modeling, through flow phantom measurements, and studied in vivo. This paper investigates errors from estimating volumetric flow using a commercial ultrasound scanner and the common assumptions made in the literature. The theoretical model shows, e.g. that volume flow is underestimated by 15%, when the scan plane is off-axis with the vessel center by 28% of the vessel radius. The error sources were also studied in vivo under realistic clinical conditions, and the theoretical results were applied for correcting the volume flow errors. Twenty dialysis patients with arteriovenous fistulas were scanned to obtain vector flow maps of fistulas. When fitting an ellipsis to cross-sectional scans of the fistulas, the major axis was on average 10.2mm, which is 8.6% larger than the minor axis. The ultrasound beam was on average 1.5mm from the vessel center, corresponding to 28% of the semi-major axis in an average fistula. Estimating volume flow with an elliptical, rather than circular, vessel area and correcting the ultrasound beam for being off-axis, gave a significant (p=0.008) reduction in error from 31.2% to 24.3%. The error is relative to the Ultrasound Dilution Technique, which is considered the gold standard for volume flow estimation for dialysis patients. The study shows the importance of correcting for volume flow errors, which are often made in clinical practice.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Arteriovenous fistula; Error sources; Transverse oscillation; Volume flow

Mesh:

Year:  2016        PMID: 27164045     DOI: 10.1016/j.ultras.2016.04.023

Source DB:  PubMed          Journal:  Ultrasonics        ISSN: 0041-624X            Impact factor:   2.890


  4 in total

Review 1.  Vector velocity estimation of blood flow - A new application in medical ultrasound.

Authors:  Kristoffer Lindskov Hansen; Michael Bachmann Nielsen; Jørgen Arendt Jensen
Journal:  Ultrasound       Date:  2017-06-05

2.  Comparison of hemodialysis arteriovenous fistula blood flow rates measured by Doppler ultrasound and phase-contrast magnetic resonance imaging.

Authors:  Yong He; Yan-Ting Shiu; Daniel B Pike; Prabir Roy-Chaudhury; Alfred K Cheung; Scott A Berceli
Journal:  J Vasc Surg       Date:  2018-05-18       Impact factor: 4.268

3.  Atherosclerotic Lesions in the Superficial Femoral Artery (SFA) Characterized with Velocity Ratios using Vector Velocity Ultrasound.

Authors:  Peter Møller Hansen; Kristoffer Lindskov Hansen; Mads Møller Pedersen; Theis Lange; Lars Lönn; Jørgen Arendt Jensen; Michael Bachmann Nielsen
Journal:  Ultrasound Int Open       Date:  2018-09-18

Review 4.  Advances in vascular anatomy and pathophysiology using high resolution and multiparametric sonography.

Authors:  Petrucci Ilaria; Meola Mario; Fiorina Ilaria
Journal:  J Vasc Access       Date:  2021-08-02       Impact factor: 2.283

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.