Literature DB >> 27163613

Long-term Visual and Refractive Outcomes After LASIK for High Myopia and Astigmatism From -8.00 to -14.25 D.

Dan Z Reinstein, Glenn I Carp, Timothy J Archer, Tariq A Lewis, Marine Gobbe, Johnny Moore, Tara Moore.   

Abstract

PURPOSE: To evaluate outcomes of high myopic LASIK using the MEL 80 excimer laser (Carl Zeiss Meditec, Jena, Germany).
METHODS: Retrospective analysis of 479 consecutive high myopic LASIK procedures (318 patients) using the MEL 80 excimer laser and VisuMax femtosecond laser (Carl Zeiss Meditec) in 77% of cases or zero compression Hansatome microkeratome (Bausch & Lomb, Rochester, NY) in 23% of cases. Inclusion criteria were preoperative spherical equivalent refraction (SEQ) of between -8.00 and -14.25 diopters (D) and corrected distance visual acuity (CDVA) of 20/20 or better. Patients were observed for a minimum of 1 year. Flap thickness was between 80 and 160 µm and optical zone was between 5.75 and 6.50 mm. Standard outcomes analysis was performed.
RESULTS: Mean attempted SEQ was -9.39 ± 1.22 D (range: -8.00 to -14.18 D) and mean cylinder was -1.03 ± 0.84 D (range: 0.00 to -4.50 D). Mean age was 37 ± 9 years (range: 21 to 60 years) with 54% female patients. Postoperative SEQ was ±0.50 D in 55% and ±1.00 D in 83% of eyes after primary treatment. After re-treatment, 69% of eyes were within ±0.50 D and 95% were within ±1.00 D. UDVA was 20/20 or better in 89% of eyes after final treatment. One line of CDVA was lost in 3% of eyes and no eyes lost two or more lines. Statistically significant increases (P < .001) were measured in contrast sensitivity (CSV-1000) at 12 and 18 cycles per degree.
CONCLUSIONS: The MEL 80 excimer laser was found to achieve high efficacy and safety for treatment of high myopia between -8.00 and -14.25 D and up to -4.50 D of cylinder. [J Refract Surg. 2016;32(5):290-297.]. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27163613     DOI: 10.3928/1081597X-20160310-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

1.  Anatomical and Visual Outcomes after LASIK Performed in Myopic Eyes with the WaveLight® Refractive Suite (Alcon® Laboratories Inc., USA).

Authors:  Imene Salah-Mabed; Sarah Moran; Emmanuelle Perez; Guillaume Debellemanière; Damien Gatinel
Journal:  J Ophthalmol       Date:  2020-10-03       Impact factor: 1.909

2.  Altered spontaneous brain activity pattern in patients with high myopia using amplitude of low-frequency fluctuation: a resting-state fMRI study.

Authors:  Xin Huang; Fu-Qing Zhou; Yu-Xiang Hu; Xiao-Xuan Xu; Xiong Zhou; Yu-Lin Zhong; Jun Wang; Xiao-Rong Wu
Journal:  Neuropsychiatr Dis Treat       Date:  2016-11-14       Impact factor: 2.570

3.  Matched population comparison of visual outcomes and patient satisfaction between 3 modalities for the correction of low to moderate myopic astigmatism.

Authors:  Sri Ganesh; Sheetal Brar; Archana Pawar
Journal:  Clin Ophthalmol       Date:  2017-07-03

4.  Predictive Factors for Successful High Myopia Treatment Using High-Frequency Laser-In-Situ Keratomileusis.

Authors:  Widya Artini; Setyo B Riyanto; Johan A Hutauruk; Tjahjono D Gondhowiardjo; Aria Kekalih
Journal:  Open Ophthalmol J       Date:  2018-07-23

5.  Visual and Refractive Outcomes of Small-Incision Lenticule Extraction in High Myopia: 5-Year Results.

Authors:  Alper Ağca; İhsan Çakır; Beril Tülü Aygün; Dilek Yaşa; Yusuf Yıldırım; Burçin Kepez Yıldız; Ahmet Demirok
Journal:  J Ophthalmol       Date:  2018-10-21       Impact factor: 1.909

6.  Refractive, visual, and subjective quality of vision outcomes for very high myopia LASIK from - 10.00 to - 13.50 diopters.

Authors:  Avi Wallerstein; Joseph Wai Keung Kam; Mathieu Gauvin; Eser Adiguzel; Mounir Bashour; Ananda Kalevar; Mark Cohen
Journal:  BMC Ophthalmol       Date:  2020-06-17       Impact factor: 2.209

7.  Comparison of posterior corneal elevation after SMILE and FS-LASIK in correcting myopia over -9.0 diopters.

Authors:  Yu Zhao; Yishan Qian; Xun Chen; Xueyi Zhou; Bing Qin; Xingtao Zhou
Journal:  Ann Transl Med       Date:  2021-03

8.  Precision and Normative Values of a New Computerized Chart for Contrast Sensitivity Testing.

Authors:  Giacomo Savini; Antonio Calossi; Domenico Schiano-Lomoriello; Piero Barboni
Journal:  Sci Rep       Date:  2019-11-12       Impact factor: 4.379

  8 in total