Literature DB >> 27159500

Comparison of centring ability and transportation between four nickel titanium instrumentation techniques by micro-computed tomography.

N Saberi1, S Patel1, F Mannocci1.   

Abstract

AIM: To compare the centring ability and transportation of ProTaper Next (PTN), ProTaper Universal (PTU), Race 123 and RevoS using micro-computed tomography (μCT).
METHODOLOGY: Sixty mesial root canals of thirty mandibular molars were divided virtually into coronal, middle and apical thirds, and two reproducible reference points were marked on the external surface of the roots creating 360 measurement points. Samples were randomly allocated to four NiTi instrumentation techniques. Group 1: PTU up to F2 (n = 16), group 2: PTN up to X2 (n = 18), group 3: Race 123 up to T2 (n = 12) and group 4: RevoS up to SU (n = 14). To reproduce a clinical situation, samples were prepared on a phantom head using a surgical operating microscope. Samples were scanned pre- and postoperatively using μCT to compare and calculate the transportation and centring ratio. The data were analysed using parametric statistics.
RESULTS: In the coronal and middle third of the root canals, there were significant differences in centring between PTN and PTU (coronal P < 0.001), PTN and RevoS (coronal P < 0.001), Race and PTU (coronal P < 0.01), Race and RevoS (coronal P < 0.01), PTN and RevoS (middle P < 0.01) and Race and RevoS (P < 0.05). Furthermore, there were significant differences in centring between PTN root canal preparations and other instruments in the apical third (PTN and PTU P < 0.01, PTN and Race P < 0.001, PTN and RevoS P < 0.001). In terms of transportation, in the coronal third, there was a significant difference between PTN and PTU (P < 0.05). However, there were no significant differences between the other instruments. In the middle third, significant differences were observed between PTN and PTU (P < 0.05), PTN and RevoS (P < 0.05), Race and PTU (P < 0.05) and Race and RevoS (P < 0.05). However, there were no significant differences between other systems. There was no significant difference in terms of transportation between the four systems in the apical third.
CONCLUSIONS: ProTaper Next prepared more centred root canal shapes when compared with Race, PTU and RevoS. In the coronal and middle third of the root canals, the differences in centring between PTN and PTU/RevoS were significant. PTN root canal preparations were more centred than those achieved with all other instruments in the apical third.
© 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  NiTi; ProTaper Next; RevoS; canal transportation; centring ratio; micro-CT

Mesh:

Substances:

Year:  2016        PMID: 27159500     DOI: 10.1111/iej.12658

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  3 in total

1.  Comparative evaluation of the shaping ability of single-file system versus multi-file system in severely curved root canals.

Authors:  Guohua Yuan; Guobin Yang
Journal:  J Dent Sci       Date:  2018-02-01       Impact factor: 2.080

2.  Micro-Computed Tomography (Micro-CT) Evaluation of Effects of Different Rotary Glide Path Techniques on Canal Transportation and Centering in Curved Root Canals.

Authors:  Gabrielė Česaitienė; Tadas Venskutonis; Vita Mačiulskienė; Vaidotas Cicėnas; Vykintas Samaitis; Elena Jasiūnienė
Journal:  Med Sci Monit       Date:  2019-08-24

3.  Comparative Assessment of Canal Transportation, Dentin Loss, and Remaining Root Filling Material by Different Retreatment Files An In vitro Cross-Sectional Study.

Authors:  Afzal Ali; Prahlad Saraf; Laxmikant Kamatagi; Sandhya Khasnis
Journal:  Contemp Clin Dent       Date:  2021-03-20
  3 in total