Literature DB >> 27158403

A novel technique of unilateral percutaneous kyphoplasty achieves effective biomechanical strength and reduces radiation exposure.

Yan Zhuang1, Lei Yang2, Haijun Li3, Yajun Ren4, Xiaojian Cao2.   

Abstract

PURPOSE: To develop a novel technique of percutaneous kyphoplasty (PKP) with effective biomechanical strength and lower radiation exposure.
METHODS: Thirty fresh lumbar vertebrae isolated from six hogs were decalcified and compressed to induce osteoporotic vertebral compression fractures. Kyphoplasty was performed using three different techniques (ten for each group): conventional unilateral approach (group A), conventional bilateral approach (group B) and novel unilateral approach (group C). Biomechanical indexes including Yield load and stiffness were tested before and after kyphoplasty. The anterior height of each vertebral body (AHVB) was measured before compression, after compression and after kyphoplasty. Frequency of C-arm use and volume of bone cement were also recorded in the process.
RESULTS: Compared with group A, our novel technique in group C can significantly improve the recovery of AHVB after compression fractures. However, there was no statistical difference between group B and group C. Values of Yield load in both group B and group C were statistically higher than that in group A, however, no significant difference was found between group B and C. Statistical results of stiffness were similar to Yield load. Regarding volume of bone cement and radiation exposure, the novel technique in group C needed more bone cement and fluoroscopy use than in group A but less than in group B.
CONCLUSIONS: This novel device makes unilateral kyphoplasty feasible, safe and effective. In the premise of guaranteed biomechanical strength, the new technique significantly reduces risk of radiation exposure in kyphoplasty.

Entities:  

Keywords:  Compression fracture; biomechanics; bone cement leakage; radiation exposure; unilateral percutaneous kyphoplasty

Year:  2016        PMID: 27158403      PMCID: PMC4846960     

Source DB:  PubMed          Journal:  Am J Transl Res            Impact factor:   4.060


  18 in total

1.  Unilateral transpedicular percutaneous vertebroplasty using puncture simulation.

Authors:  Ken Kobayashi; Kenji Takizawa; Masamichi Koyama; Misako Yoshimatsu; Shinjiro Sakaino; Yasuo Nakajima
Journal:  Radiat Med       Date:  2006-04

2.  Comparison of unipedicular and bipedicular kyphoplasty on the stiffness and biomechanical balance of compression fractured vertebrae.

Authors:  BaiLing Chen; YiQiang Li; DengHui Xie; XiaoXi Yang; ZhaoMin Zheng
Journal:  Eur Spine J       Date:  2011-03-08       Impact factor: 3.134

3.  A comparison between unilateral transverse process-pedicle and bilateral puncture techniques in percutaneous kyphoplasty.

Authors:  Liang Yan; Renqi Jiang; Baorong He; Tuanjiang Liu; Dingjun Hao
Journal:  Spine (Phila Pa 1976)       Date:  2014-12-15       Impact factor: 3.468

4.  Percutaneous vertebroplasty for pain relief and spinal stabilization.

Authors:  J D Barr; M S Barr; T J Lemley; R M McCann
Journal:  Spine (Phila Pa 1976)       Date:  2000-04-15       Impact factor: 3.468

5.  Unilateral or bilateral percutaneous vertebroplasty for acute osteoporotic vertebral fracture: a prospective study.

Authors:  Li-guo Zhang; Xin Gu; Hai-long Zhang; Qing-gan Zhang; Xiao-bing Cai; Kun Tao
Journal:  J Spinal Disord Tech       Date:  2015-03

6.  Clinical and radiographic results of unilateral transpedicular balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures.

Authors:  S-B Lee; K-S Cho; P-W Huh; D-S Yoo; S-G Kang; D-S Kim; C-K Park
Journal:  Acta Neurochir Suppl       Date:  2008

7.  Radiation exposure to the surgeon and the patient during kyphoplasty.

Authors:  Thomas E Mroz; Takayuki Yamashita; William J Davros; Isador H Lieberman
Journal:  J Spinal Disord Tech       Date:  2008-04

8.  Epidural cement leakage through pedicle violation after balloon kyphoplasty causing paraparesis in osteoporotic vertebral compression fractures - a report of two cases.

Authors:  Si-Young Park; Hitesh N Modi; Seung-Woo Suh; Jae-Young Hong; Won Noh; Jae-Hyuk Yang
Journal:  J Orthop Surg Res       Date:  2010-08-06       Impact factor: 2.359

9.  Early clinical outcome and complications related to balloon kyphoplasty.

Authors:  Martin Bergmann; Ludwig Oberkircher; Christopher Bliemel; Thomas Manfred Frangen; Steffen Ruchholtz; Antonio Krüger
Journal:  Orthop Rev (Pavia)       Date:  2012-06-21

10.  A randomized trial of balloon kyphoplasty and nonsurgical management for treating acute vertebral compression fractures: vertebral body kyphosis correction and surgical parameters.

Authors:  Jan Van Meirhaeghe; Leonard Bastian; Steven Boonen; Jonas Ranstam; John B Tillman; Douglas Wardlaw
Journal:  Spine (Phila Pa 1976)       Date:  2013-05-20       Impact factor: 3.468

View more
  1 in total

1.  Is It Necessary to Approach the Severe Osteoporotic Vertebral Biconcave-Shaped Fracture Bilaterally During the Process of PKP?

Authors:  Bing Tan; Qi-Yuan Yang; Bin Fan; Chao Lei; Zhen-Ming Hu
Journal:  J Pain Res       Date:  2021-06-04       Impact factor: 3.133

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.