Literature DB >> 27158287

A portable paper-based microfluidic platform for multiplexed electrochemical detection of human immunodeficiency virus and hepatitis C virus antibodies in serum.

Chen Zhao1, Xinyu Liu1.   

Abstract

This paper presents a portable paper-based microfluidic platform for multiplexed electrochemical detection of antibody markers of human immunodeficiency virus (HIV) and hepatitis C virus (HCV) in serum samples. To our best knowledge, this is the first paper-based electrochemical immunosensing platform, with multiplexing and telemedicine capabilities, for diagnosing HIV/HCV co-infection. The platform consists of an electrochemical microfluidic paper-based immunosensor array (E-μPIA) and a handheld multi-channel potentiostat, and is capable of performing enzyme-linked immunosorbent assays simultaneously on eight samples within 20 min (using a prepared E-μPIA). The multiplexing feature of the platform allows it to produce multiple measurement data for HIV and HCV markers from a single run, and its wireless communication module can transmit the results to a remote site for telemedicine. The unique integration of paper-based microfluidics and mobile instrumentation renders our platform portable, low-cost, user-friendly, and high-throughput.

Entities:  

Year:  2016        PMID: 27158287      PMCID: PMC4833732          DOI: 10.1063/1.4945311

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  28 in total

1.  A perspective on paper-based microfluidics: Current status and future trends.

Authors:  Xu Li; David R Ballerini; Wei Shen
Journal:  Biomicrofluidics       Date:  2012-03-02       Impact factor: 2.800

2.  Electrochemical detection in paper-based analytical devices using microwire electrodes.

Authors:  Jaclyn A Adkins; Charles S Henry
Journal:  Anal Chim Acta       Date:  2015-08-19       Impact factor: 6.558

Review 3.  Coinfection with hepatitis C virus and human immunodeficiency virus: virological, immunological, and clinical outcomes.

Authors:  Yaron Rotman; T Jake Liang
Journal:  J Virol       Date:  2009-05-06       Impact factor: 5.103

4.  Colored wax-printed timers for two-dimensional and three-dimensional assays on paper-based devices.

Authors:  Chen-Hsun Weng; Ming-Yi Chen; Chi-Hsiang Shen; Ruey-Jen Yang
Journal:  Biomicrofluidics       Date:  2014-11-18       Impact factor: 2.800

5.  A disposable paper-based electrochemical sensor with an addressable electrode array for cancer screening.

Authors:  Shenguang Ge; Lei Ge; Mei Yan; Xianrang Song; Jinghua Yu; Jiadong Huang
Journal:  Chem Commun (Camb)       Date:  2012-08-13       Impact factor: 6.222

6.  Universal mobile electrochemical detector designed for use in resource-limited applications.

Authors:  Alex Nemiroski; Dionysios C Christodouleas; Jonathan W Hennek; Ashok A Kumar; E Jane Maxwell; Maria Teresa Fernández-Abedul; George M Whitesides
Journal:  Proc Natl Acad Sci U S A       Date:  2014-08-04       Impact factor: 11.205

7.  Effects of temperature and relative humidity on the stability of paper-immobilized antibodies.

Authors:  Jingyun Wang; Brian Yiu; Jaclyn Obermeyer; Carlos D M Filipe; John D Brennan; Robert Pelton
Journal:  Biomacromolecules       Date:  2012-02-01       Impact factor: 6.988

8.  Assessment of the ability of a fourth-generation immunoassay for human immunodeficiency virus (HIV) antibody and p24 antigen to detect both acute and recent HIV infections in a high-risk setting.

Authors:  Mark W Pandori; John Hackett; Brian Louie; Ana Vallari; Teri Dowling; Sally Liska; Jeffrey D Klausner
Journal:  J Clin Microbiol       Date:  2009-06-17       Impact factor: 5.948

9.  Electrochemical enzyme-linked immunosorbent assay featuring proximal reagent generation: detection of human immunodeficiency virus antibodies in clinical samples.

Authors:  Alyajahan Bhimji; Alexandre A Zaragoza; Ludovic S Live; Shana O Kelley
Journal:  Anal Chem       Date:  2013-07-03       Impact factor: 6.986

10.  The natural history of hepatitis C virus (HCV) infection.

Authors:  Stephen L Chen; Timothy R Morgan
Journal:  Int J Med Sci       Date:  2006-04-01       Impact factor: 3.738

View more
  21 in total

Review 1.  The Current and Future Use of Telemedicine in Infectious Diseases Practice.

Authors:  Caitlin E Coombes; Megan E Gregory
Journal:  Curr Infect Dis Rep       Date:  2019-10-19       Impact factor: 3.725

2.  Point-of-Care Based Electrochemical Immunoassay for Epstein-Barr Virus Detection.

Authors:  Miao Yu; Ming Liu; Yuan Li
Journal:  J Anal Methods Chem       Date:  2022-05-30       Impact factor: 2.594

3.  Paper-based diagnostic devices for clinical paraquat poisoning diagnosis.

Authors:  Chen-Meng Kuan; Szu-Ting Lin; Tzung-Hai Yen; Yu-Lin Wang; Chao-Min Cheng
Journal:  Biomicrofluidics       Date:  2016-06-21       Impact factor: 2.800

4.  Counting-based microfluidic paper-based devices capable of analyzing submicroliter sample volumes.

Authors:  Md Almostasim Mahmud; Eric J M Blondeel; Brendan D MacDonald
Journal:  Biomicrofluidics       Date:  2020-01-10       Impact factor: 2.800

Review 5.  Microfluidic immunoassay for detection of serological antibodies: A potential tool for rapid evaluation of immunity against SARS-CoV-2.

Authors:  Hogi Hartanto; Minghui Wu; Miu Ling Lam; Ting-Hsuan Chen
Journal:  Biomicrofluidics       Date:  2020-12-14       Impact factor: 2.800

6.  Development of a Label-Free Immunosensor for Clusterin Detection as an Alzheimer's Biomarker.

Authors:  Kamrul Islam; Samar Damiati; Jagriti Sethi; Ahmed Suhail; Genhua Pan
Journal:  Sensors (Basel)       Date:  2018-01-20       Impact factor: 3.576

Review 7.  Multiplexed Electrochemical Immunosensors for Clinical Biomarkers.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-27       Impact factor: 3.576

Review 8.  Advanced "lab-on-a-chip" to detect viruses - Current challenges and future perspectives.

Authors:  Jianjian Zhuang; Juxin Yin; Shaowu Lv; Ben Wang; Ying Mu
Journal:  Biosens Bioelectron       Date:  2020-05-12       Impact factor: 10.618

9.  Features in Microfluidic Paper-Based Devices Made by Laser Cutting: How Small Can They Be?

Authors:  Md Almostasim Mahmud; Eric J M Blondeel; Moufeed Kaddoura; Brendan D MacDonald
Journal:  Micromachines (Basel)       Date:  2018-05-07       Impact factor: 2.891

Review 10.  Nano-engineered screen-printed electrodes: A dynamic tool for detection of viruses.

Authors:  Mazhar Sher; Aroosha Faheem; Waseem Asghar; Stefano Cinti
Journal:  Trends Analyt Chem       Date:  2021-06-21       Impact factor: 14.908

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.