In-vitro investigation of cerebral-perfusion effects of a rotary blood pump installed in the descending aorta.

Mohammad Amin Rezaienia1, Gordon Paul1, Eldad Avital1, Akbar Rahideh2, Martin Terry Rothman3, Theodosios Korakianitis4.   

Abstract

This study describes use of a cardiovascular simulator to replicate the hemodynamic responses of the cerebrovascular system with a mechanical circulatory support device operating in the descending aorta. To do so, a cerebral autoregulation unit was developed which replicates the dilation and constriction of the native cerebrovascular resistance system and thereby regulates the cerebral flow rate within defined limits. The efficacy of the replicated autoregulation mechanism was investigated by introducing a number of step alterations in mean aortic pressure and monitoring the cerebral flow. The steady responses of the cerebral flow to changes in mean aortic pressure were in good agreement with clinical data. Next, a rotary pump, modeling a mechanical circulatory support device, was installed in the descending aorta and the hemodynamic responses of the cerebral system were investigated over a wide range of pump operating conditions. Insertion of a mechanical circulatory support device in the descending aorta presented an improved cardiac output as a result of afterload reduction. It was observed that the primary drop in cerebral flow, caused by the pump in the descending aorta, was compensated over the course of five seconds due to a gradual decrease in cerebrovascular resistance. The experimental results suggest that the implantation of a mechanical circulatory support device in the descending aorta, a less invasive procedure than typical mechanical circulatory support implantation, will not have an adverse effect on the cognitive function, provided that the cerebral autoregulation is largely unimpaired.
Copyright © 2016. Published by Elsevier Ltd.

Entities:  

Keywords:  Cardiovascular simulator VAD; MCS; Minimally invasive

Mesh:

Year:  2016        PMID: 27155746     DOI: 10.1016/j.jbiomech.2016.04.027

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Measurement of hemodynamic changes with the axial flow blood pump installed in descending aorta.

Authors:  Eiji Okamoto; Tetsuya Yano; Hidekazu Miura; Yasuyuki Shiraishi; Tomoyuki Yambe; Yoshinori Mitamura
Journal:  J Artif Organs       Date:  2017-09-08       Impact factor: 1.731

2.  Optimization of Axial Pump Characteristic Dimensions and Induced Hemolysis for Mechanical Circulatory Support Devices.

Authors:  Theodosios Korakianitis; Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Sahand Mozafari
Journal:  ASAIO J       Date:  2018 Nov/Dec       Impact factor: 2.872

3.  Computational Parametric Study of the Axial and Radial Clearances in a Centrifugal Rotary Blood Pump.

Authors:  Mohammad Amin Rezaienia; Gordon Paul; Eldad Avital; Martin Rothman; Theodosios Korakianitis
Journal:  ASAIO J       Date:  2018 Sep/Oct       Impact factor: 2.872

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.