Literature DB >> 27154666

Simultaneous determination of ethionamide and pyrazinamide using poly(l-cysteine) film-modified glassy carbon electrode.

Bruno Regis Lyrio Ferraz1, Fernando Roberto Figueiredo Leite2, Andréa Renata Malagutti2.   

Abstract

A selective, simple and rapid square wave voltammetry method, based on electropolymerization of l-cysteine (poly(l-Cys)) on a glassy carbon electrode (GCE), was developed in this study for simultaneous determination of ethionamide and pyrazinamide. Electroanalytical and electrochemical properties of the poly(l-Cys)/GCE were investigated by cyclic voltammetry (CV), square wave voltammetry (SWV), electrochemical impedance spectroscopy (EIS) and scanning electrochemical microscopy (SECM). The cyclic voltammetry studies revealed an remarkable electrocatalytic activity of poly(l-Cys)/GCE on ethionamide and pyrazinamide at pH 1.0. The best potential separation between the reduction peaks of the drugs in a mixed solution was found to be 0.14V. It was also found that pyrazinamide exhibits a reversible wave with Epc and Epa at -404mV and -347mV (versus EAg/AgCl), respectively, while ethionamide presents an irreversible reduction peak at Epc=-536mV. The optimized calibration curves for simultaneous determination of ethionamide and pyrazinamide exhibited good and high linear responses within the concentration range 2.38-248.0µmolL(-1) and 0.476-51.2µmolL(-1), respectively. The limit of detection was found to be 0.531µmolL(-1) for ethionamide and 0.113µmolL(-1) for pyrazinamide. The poly(l-Cys)/GCE-based square wave voltammetry method was successfully used to determine ethionamide and pyrazinamide in human urine and blood serum.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Ethionamide; Poly(l-Cys)/GCE; Pyrazinamide; Simultaneous determination; Square-wave voltammetry

Mesh:

Substances:

Year:  2016        PMID: 27154666     DOI: 10.1016/j.talanta.2016.03.058

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Electrooxidation of sulfanilamide and its voltammetric determination in pharmaceutical formulation, human urine and serum on glassy carbon electrode.

Authors:  Bruno R L Ferraz; Tiago Guimarães; Demetrius Profeti; Luciene P R Profeti
Journal:  J Pharm Anal       Date:  2017-10-31

2.  An Enzyme-Induced Novel Biosensor for the Sensitive Electrochemical Determination of Isoniazid.

Authors:  Rajasekhar Chokkareddy; Natesh Kumar Bhajanthri; Gan G Redhi
Journal:  Biosensors (Basel)       Date:  2017-06-05

3.  Graphene oxide-based electrochemical activation of ethionamide towards enhanced biological activity.

Authors:  Balaji B Mulik; Sambhaji T Dhumal; Vijay S Sapner; Naziya N M A Rehman; Prashant P Dixit; Bhaskar R Sathe
Journal:  RSC Adv       Date:  2019-11-01       Impact factor: 4.036

4.  Electrochemical sensor using poly-(l-cysteine) functionalized CuO nanoneedles/N-doped reduced graphene oxide for detection of lead ions.

Authors:  Suling Yang; Panpan Liu; Yuxin Wang; Ziling Guo; Ruifan Tan; Lingbo Qu
Journal:  RSC Adv       Date:  2020-05-14       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.