[Analysis of Cut-off Value in Screening of Thalassemia by Capillary Hemoglobin Electrophoresis for Pregnant Women from Shenzhen Region of China].

Mei Huo1, Wen-Yuan Wu1, Mei Liu2, Zhi-Biao Gan1, Wei-Yu Mao1, Rong-Yao Lin1, Ai-Qin Liu1, Gui-Rong He3.   

Abstract

OBJECTIVE: To investigate the cut-off value in screening of thalassemia in pregnant women from Shenzhen region by capillary hemoglobin electrophoresis.
METHODS: The data of capillary hemoglobin electrophoresis and genetic diagnosis of thalassemia from 2122 examined prenatal women were retrospectively analyzed. Capillary hemoglobin electrophoresis and α-, β- genetic diagnosis of thalassemia were carried out for every woman. Hemoglobin electrophoresis was performed using Capillarys 2 full-automated electrophoresis instrument. Gap polymerase chain reaction and reverse dot blot were used for genetic diagnosis of thalassemia genotyping test. The cut-off value in screening of thalassemia was determined by receiver operating characteristic curve and next to analyze the value of HbA2 and HbF in screening of thalassemia using the decided cut-off value.
RESULTS: The areas under the curve (AUC(Roc)) of HbA2 for diagnosis of α-, β- thalassemia were 0.75 and 0.981 respectively, and the AUC(Roc) of HbF for diagnosis of β-thalassemia was 0.787. When HbA2 ≤ 2.55 was taken as the cut-off value of HbA2 for diagnosis of α-thalassemia, the sensitivity, specificity, positive likelihood ratio (LR(+)) and negative likelihood ratio (LR(-)) were 89.5%, 54.8%, 1.98, 0.19 respectively. When HbA2 ≥3.9 was taken as the cut off value of HbA2 for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 96.1%, 99.8% 480.5, 0.04 respectively. When HbF ≥0.75 was taken as the cut off value of HbF for diagnosis of β-thalassemia, the sensitivity, specificity, LR(+) and LR(-) were 83.6%, 61.8% respectively.
CONCLUSION: The cut-off value in screening of thalassemia by capillarys 2 full automated electrophoresis instrument is different from that of the traditional method of hemoglobin electrophoresis, such as cellulose acetate membrane electrophoresis and agarose gel electrophoresis. Each laboratory should establish their own respective cut off value.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27151025     DOI: 10.7534/j.issn.1009-2137.2016.02.043

Source DB:  PubMed          Journal:  Zhongguo Shi Yan Xue Ye Xue Za Zhi        ISSN: 1009-2137


  1 in total

1.  Wooden-Tip Electrospray Mass Spectrometry Characterization of Human Hemoglobin in Whole Blood Sample for Thalassemia Screening: A Pilot Study.

Authors:  Tingting Huang; Ting Huang; Yongyi Zou; Kang Xie; Yinqin Shen; Wen Zhang; Shuhui Huang; Yanqiu Liu; Bicheng Yang
Journal:  Molecules       Date:  2022-06-20       Impact factor: 4.927

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.