Alireza Mirzaei , Amir R Jalilian 1 , Mehdi Akhlaghi , Davood Beiki . Show Affiliations »
Abstract
INTRODUCTION: Gallium-68 citrate has been successfully applied in the PET imaging of infections and inflammation in some centers; however further evaluation of the tracer in inflammation models is of great importance. METHODS: 68Ga-citrate prepared from [68Ga]GaCl3 (eluted form an SnO2 based 68Ge/68Ga generator) and sodium citrate at optimized conditions followed by quality control tests was injected to normal and turpentine-oil induced rats PET/CT imaging studies up to 290 min. RESULTS: 68Ga-citrate was prepared with acceptable radiochemical purity (>99 ITLC, >99% HPLC), specific activity (28-30 GBq/mM), chemical purity (Sn, Fe <0.3 ppm; Zn<0.2 ppm) in 15 min at 50°C. PET/CT imaging of the tracer demonstrated early detection of inflamed site in animal models in 60-80 min. CONCLUSION: This study demonstrated possible early detection of inflammation foci in vivo using 68Ga-citrate prepared using commercially available 68Ge/68Ga generators for PET imaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
INTRODUCTION: Gallium-68 citrate has been successfully applied in the PET imaging of infections and inflammation in some centers; however further evaluation of the tracer in inflammation models is of great importance. METHODS: 68Ga-citrate prepared from [68Ga]GaCl3 (eluted form an SnO2 based 68Ge/68Ga generator) and sodium citrate at optimized conditions followed by quality control tests was injected to normal and turpentine-oil induced rats PET/CT imaging studies up to 290 min. RESULTS: 68Ga-citrate was prepared with acceptable radiochemical purity (>99 ITLC, >99% HPLC), specific activity (28-30 GBq/mM), chemical purity (Sn, Fe <0.3 ppm; Zn <0.2 ppm) in 15 min at 50°C. PET/CT imaging of the tracer demonstrated early detection of inflamed site in animal models in 60-80 min. CONCLUSION: This study demonstrated possible early detection of inflammation foci in vivo using 68Ga-citrate prepared using commercially available 68Ge/68Ga generators for PET imaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Entities: Chemical
Disease
Species
Keywords:
68Ga-citrate; PET/CT; nuclids.; quality control; rats; turpentine oil
Mesh: See more »
Substances: See more »
Year: 2016
PMID: 27150277 DOI: 10.2174/1874471009666160506130108
Source DB: PubMed Journal: Curr Radiopharm ISSN: 1874-4710