Precision of Dental Implant Digitization Using Intraoral Scanners.

Tabea V Flügge, Wael Att, Marc C Metzger, Katja Nelson.   

Abstract

PURPOSE: The digitization of scanbodies on dental implants is required to use computer-aided design/computer-assisted manufacture processes for implant prosthetics. Little is known about the accuracy of scanbody digitization with intraoral scanners and dental lab scanners. This study aimed to examine the precision of different intraoral digital impression systems as well as a dental lab scanner using commercially available implant scanbodies.
MATERIALS AND METHODS: Two study models with a different number and distribution of dental implant scanbodies were produced from conventional implant impressions. The study models were scanned using three different intraoral scanners (iTero, Cadent; Trios, 3Shape; and True Definition, 3M ESPE) and a dental lab scanner (D250, 3Shape). For each study model, 10 scans were performed per scanner to produce repeated measurements for the calculation of precision. The distance and angulation between the respective scanbodies were measured. The results of each scanning system were compared using analysis of variance, and post hoc Tukey test was conducted for a pairwise comparison of scanning devices.
RESULTS: The precision values of the scanbodies varied according to the distance between the scanbodies and the scanning device. A distance of a single tooth space and a jaw-traversing distance between scanbodies produced significantly different results for distance and angle measurements between the scanning systems (P < .05).
CONCLUSION: The precision of intraoral scanners and the dental lab scanner was significantly different. The precision of intraoral scanners decreased with an increasing distance between the scanbodies, whereas the precision of the dental lab scanner was independent of the distance between the scanbodies.

Mesh:

Substances:

Year:  2016        PMID: 27148990     DOI: 10.11607/ijp.4417

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  22 in total

Review 1.  Precision and practical usefulness of intraoral scanners in implant dentistry: A systematic literature review.

Authors:  Ignacio García-Gil; Jorge Cortés-Bretón-Brinkmann; Jaime Jiménez-García; Jesus Peláez-Rico; María-Jesús Suárez-García
Journal:  J Clin Exp Dent       Date:  2020-08-01

2.  In Vitro Comparison of Three Intraoral Scanners for Implant-Supported Dental Prostheses.

Authors:  Vitória Costa; António Sérgio Silva; Rosana Costa; Pedro Barreiros; Joana Mendes; José Manuel Mendes
Journal:  Dent J (Basel)       Date:  2022-06-15

3.  Accuracy of commercial intraoral scanners.

Authors:  Mattia Sacher; Georg Schulz; Hans Deyhle; Kurt Jäger; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-24

Review 4.  Intraoral Scanner Technologies: A Review to Make a Successful Impression.

Authors:  Raphaël Richert; Alexis Goujat; Laurent Venet; Gilbert Viguie; Stéphane Viennot; Philip Robinson; Jean-Christophe Farges; Michel Fages; Maxime Ducret
Journal:  J Healthc Eng       Date:  2017-09-05       Impact factor: 2.682

Review 5.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

6.  A comparison of the accuracy of intraoral scanners using an intraoral environment simulator.

Authors:  Hye-Nan Park; Young-Jun Lim; Won-Jin Yi; Jung-Suk Han; Seung-Pyo Lee
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

Review 7.  Trueness and precision of digital implant impressions by intraoral scanners: a literature review.

Authors:  Minoru Sanda; Keita Miyoshi; Kazuyoshi Baba
Journal:  Int J Implant Dent       Date:  2021-07-27

8.  Bias Evaluation of the Accuracy of Two Extraoral Scanners and an Intraoral Scanner Based on ADA Standards.

Authors:  Naiyu Cui; Jiayin Wang; Xingyu Hou; Shixun Sun; Qixuan Huang; Ho-Kyung Lim; HongXin Cai; Qi Jia; Eui-Seok Lee; Heng Bo Jiang
Journal:  Scanning       Date:  2021-06-10       Impact factor: 1.932

9.  Accuracy and dimensional reproducibility by model scanning, intraoral scanning, and CBCT imaging for digital implant dentistry.

Authors:  Akira Komuro; Yoichi Yamada; Satoshi Uesugi; Hiroaki Terashima; Masashi Kimura; Hiroto Kishimoto; Tsutomu Iida; Katsuya Sakamoto; Kenichi Okuda; Kaoru Kusano; Shunsuke Baba; Takashi Sakamoto
Journal:  Int J Implant Dent       Date:  2021-06-30

Review 10.  Cone beam computed tomography in implant dentistry: recommendations for clinical use.

Authors:  Reinhilde Jacobs; Benjamin Salmon; Marina Codari; Bassam Hassan; Michael M Bornstein
Journal:  BMC Oral Health       Date:  2018-05-15       Impact factor: 2.757

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.