Literature DB >> 27148987

Comparison of Different Impression Techniques When Using the All-on-Four Implant Treatment Protocol.

Hakimeh Siadat, Marzieh Alikhasi, Elaheh Beyabanaki, Susan Rahimian.   

Abstract

PURPOSE: The aim of this in vitro study was to compare the accuracy of two different impression techniques for the All-on-Four implant therapy protocol.
MATERIALS AND METHODS: An acrylic resin analog for an edentulous maxilla with four internal connection implants (Replace Select, Nobel Biocare) was fabricated according to the All-on-Four protocol. A total of 40 impressions were made with different techniques (open and closed tray) at abutment and implant levels and poured in type IV dental stone. A coordinate measuring machine was used to record the x, y, and z coordinates and angular displacement. The measurements were compared with those obtained from the reference model. Data were analyzed with analysis of variance and t test at α = .05.
RESULTS: There was less linear and rotational displacement for the open-tray technique when compared with the closed-tray technique (P = .02 and P < .001, respectively). Impressions made at abutment level produced fewer linear and rotational displacements when compared with implant level impressions using the open-tray technique for straight and angulated implants (P = .04 and P < .001, respectively). However, less rotational dislocation was observed for impressions made with the closed-tray technique when compared with the open-tray technique at implant level (P < .001).
CONCLUSION: Choice of impression technique affected the accuracy of impressions, and less displacement was observed with the open-tray method. Abutment-level impressions with an open-tray technique were more accurate, while implant-level impressions were more accurate when a closed-tray technique was used.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27148987     DOI: 10.11607/ijp.4341

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  3 in total

1.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01

2.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

3.  To evaluate and compare the accuracy of definitive casts using various splinting methods on implant level impressions in All-on-Four treatment: An in vitro study.

Authors:  S Daya Shankar; Santosh Doddamani
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.