Literature DB >> 27147688

Cortical Bone Thickness of the Distal Part of the Tibia Predicts Bone Mineral Density.

Jason Patterson1, Chamnanni Rungprai2, Taylor Den Hartog2, Yubo Gao2, Annunziato Amendola2, Phinit Phisitkul2, John Femino2.   

Abstract

BACKGROUND: Poor bone density may affect surgical planning, treatment outcome, and postoperative protocols. Many patients with foot and ankle problems have not undergone a dual x-ray absorptiometry (DXA) scan, which is currently the gold standard for determining bone density. The purpose of this study was to determine if the cortical bone thickness (CBT) of the distal part of the tibia measured on radiographs correlated with bone mineral density.
METHODS: After exclusion criteria were applied, 167 consecutive adult patients (mean age and standard deviation [SD], 62 ± 11.62 years) who had had standardized ankle radiographs and a DXA scan within 6 months of each other were included in this retrospective study. The CBT was measured with both the gauge and the average method on standardized anteroposterior, lateral, and hindfoot alignment radiographs. The relationship between CBT in the distal part of the tibia and DXA findings in the hip, proximal part of the femur, and lumbar spine was assessed with Pearson correlations. The interrater and intrarater reliability of CBT measurements was assessed with intraclass correlation coefficients. Subgroup analysis was performed to determine the ability of CBT thresholds to predict osteoporosis.
RESULTS: Average CBT measurements on the anteroposterior, lateral, and hindfoot alignment views strongly correlated with DXA findings in the proximal part of the femur (r = 0.70, 0.64, and 0.55, respectively; p < 0.0001), the hip (r = 0.74, 0.67, and 0.53; p < 0.0001), and the lumbar spine (r = 0.61, 0.60, and 0.47; p < 0.0001). The interrater and intrarater reliability of the CBT measurements was excellent. Use of a 3.5-mm average CBT of the distal part of the tibia on the anteroposterior view as the threshold value for predicting osteoporosis (T score less than -2.5) had a sensitivity of 100%, a specificity of 25%, an accuracy of 33%, a positive predictive value of 19%, and a negative predictive value of 100%.
CONCLUSIONS: Measurement of the average CBT of the distal part of the tibia is a quick and reliable method for obtaining information on bone quality. CBT measured on standard ankle radiographs correlated strongly with DXA results and may prove to be a useful screening tool for osteoporosis. LEVEL OF EVIDENCE: Diagnostic Level II. See Instructions for Authors for a complete description of levels of evidence.
Copyright © 2016 by The Journal of Bone and Joint Surgery, Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27147688     DOI: 10.2106/JBJS.15.00795

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  7 in total

1.  Near infrared spectroscopy for measuring changes in bone hemoglobin content after exercise in individuals with spinal cord injury.

Authors:  Adina E Draghici; Diane Potart; Joseph L Hollmann; Vivian Pera; Qianqian Fang; Charles A DiMarzio; J Andrew Taylor; Mark J Niedre; Sandra J Shefelbine
Journal:  J Orthop Res       Date:  2017-06-28       Impact factor: 3.494

2.  Cortical Thickness Index of the Proximal Femur: A Radiographic Parameter for Preliminary Assessment of Bone Mineral Density and Osteoporosis Status in the Age 50 Years and Over Population.

Authors:  Bao Nt Nguyen; Hironobu Hoshino; Daisuke Togawa; Yukihiro Matsuyama
Journal:  Clin Orthop Surg       Date:  2018-05-18

3.  Radiographic predictors for bone mineral loss: Cortical thickness and index of the distal femur.

Authors:  Q-F He; H Sun; L-Y Shu; Y Zhu; X-T Xie; Y Zhan; C-F Luo
Journal:  Bone Joint Res       Date:  2018-08-04       Impact factor: 5.853

4.  Evaluation of the tibial cortical thickness accuracy in osteoporosis diagnosis in comparison with dual energy X-ray absorptiometry.

Authors:  Ahmad Fakhri Zadeh; Mohammad Ghasem Hanafi; Ali Kiasat; Marjan Mousavi
Journal:  J Family Med Prim Care       Date:  2019-02

5.  Is there a correlation between outcomes after hip arthroscopy for femoroacetabular impingement syndrome and patient cortical bone thickness?

Authors:  Edward C Beck; Kyle N Kunze; Nicole A Friel; William H Neal; Michael C Fu; Brian D Giordano; Jorge Chahla; Shane J Nho
Journal:  J Hip Preserv Surg       Date:  2019-03-15

6.  The Circle-Fit Method Helps Make Reliable Cortical Thickness Measurements Regardless of Humeral Length.

Authors:  Trevor J Shelton; Amy E Steele; Augustine M Saiz; Kent N Bachus; John G Skedros
Journal:  Geriatr Orthop Surg Rehabil       Date:  2018-12-26

7.  Cortical bone thickness of the distal radius predicts the local bone mineral density.

Authors:  Florian Schmidutz; Christoph Schopf; Shuang G Yan; Marc-Daniel Ahrend; Christoph Ihle; Christoph Sprecher
Journal:  Bone Joint Res       Date:  2021-12       Impact factor: 5.853

  7 in total