Literature DB >> 27143793

ENERGY AND ANGULAR DEPENDENCE OF RADIOPHOTOLUMINESCENT GLASS DOSEMETERS FOR EYE LENS DOSIMETRY.

E H Silva1, Ž Knežević2, L Struelens3, P Covens4, S Ueno5, F Vanhavere3, N Buls6.   

Abstract

Recent studies demonstrated that lens opacities can occur at lower radiation doses than previously accepted. In view of these studies, the International Commission of Radiological Protection recommended in 2011 to reduce the eye lens dose limit from 150 mSv/y to 20 mSv/y. This implies in the need of monitoring doses received by the eye lenses. In this study, small rod radiophotoluminescent glass dosemeters (GD-300 series; AGC, Japan) were characterized in terms of their energy (ISO 4037 X-rays narrow spectrum series, S-Cs and S-Co) and angular dependence (0  up to 90 degrees, with 2 ISO energies: N-60 and S-Cs). All acquisitions were performed at SCK•CEN-Belgium, using the ORAMED proposed cylindrical phantom. For selected energies (N-60, N-80, N-100, N-120 and N-250), the response of dosemeters irradiated on the ISO water slab phantom, at the Ruđer Bošković Institute-Croatia, was compared to those irradiated on the cylindrical phantom. GD-300 series showed good energy dependence, relative to S-Cs, on the cylindrical phantom. From 0 up to 45 degrees, the dosemeters showed no significant angular dependence, regardless whether they were tested when placed vertically or horizontally on the cylindrical phantom. However, at higher angles, some angular dependence was observed, mainly when the dosemeters were irradiated with low-energy photons (N-60). Results showed that GD-300 series have good properties related to Hp(3), although some improvements may be necessary.
© The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2016        PMID: 27143793     DOI: 10.1093/rpd/ncw104

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  2 in total

1.  Occupational radiation dose to the lens of the eye of medical staff who assist in diagnostic CT scans.

Authors:  Keisuke Nagamoto; Takashi Moritake; Koichi Nakagami; Koichi Morota; Satoru Matsuzaki; Shun-Ichi Nihei; Masayuki Kamochi; Naoki Kunugita
Journal:  Heliyon       Date:  2021-01-30

2.  A multicenter study of radiation doses to the eye lenses of clinical physicians performing radiology procedures in Japan.

Authors:  Keisuke Nagamoto; Takashi Moritake; Koichi Nakagami; Koichi Morota; Satoru Matsuzaki; Naoki Kunugita
Journal:  J Occup Health       Date:  2021-01       Impact factor: 2.708

  2 in total