Literature DB >> 27143742

The Warwick Hip Trauma Evaluation One: a randomised pilot trial comparing the X-Bolt Dynamic Hip Plating System with sliding hip screw fixation in complex extracapsular hip fractures: WHiTE (One).

X L Griffin1, N Parsons2, J McArthur3, J Achten4, M L Costa4.   

Abstract

AIMS: The aim of this study was to inform a definitive trial which could determine the clinical effectiveness of the X-Bolt Dynamic Hip Plating System compared with the sliding hip screw for patients with complex pertrochanteric fragility fractures of the femur. PATIENTS AND METHODS: This was a single centre, participant blinded, randomised, standard-of-care controlled pilot trial. Patients aged 60 years and over with AO/ASIF A2 and A3 type femoral pertrochanteric fractures were eligible.
RESULTS: The primary outcome was the EuroQoL 5 Dimension Score (EQ-5D-3L) at one year following index fixation. A total of 100 participants were recruited, and primary outcome data were available for 88 patients following losses to follow-up and withdrawals. The mean difference in EQ-5D was 0.03 (95% confidence interval -0.17, 0.120; p = 0.720.) There were no significant differences in any of the secondary outcomes measures. The recruitment and follow-up rates from this feasibility study were as predicted.
CONCLUSION: A definitive trial with 90% power to find a clinically important difference in EQ-5D would require 964 participants based upon the data from this study. We plan to start recruitment to this trial in Spring 2016. TAKE HOME MESSAGE: A definitive trial of X-Bolt Dynamic Hip Plating System is feasible and should be conducted now in order to quantify the clinical effectiveness of this novel implant. Cite this article: Bone Joint J 2016;98-B:686-9. ©2016 The British Editorial Society of Bone & Joint Surgery.

Entities:  

Keywords:  Hip fracture; Proximal femur; Quality of life; RCT; X-Bolt

Mesh:

Year:  2016        PMID: 27143742     DOI: 10.1302/0301-620X.98B5.37350

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  8 in total

Review 1.  Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis.

Authors:  Sharon R Lewis; Richard Macey; Joseph Lewis; Jamie Stokes; James R Gill; Jonathan A Cook; William Gp Eardley; Martyn J Parker; Xavier L Griffin
Journal:  Cochrane Database Syst Rev       Date:  2022-02-10

2.  Effect on health-related quality of life of the X-Bolt dynamic plating system versus the sliding hip screw for the fixation of trochanteric fractures of the hip in adults: the WHiTE Four randomized clinical trial.

Authors:  Xavier L Griffin; Juul Achten; Heather Marie O'Connor; Jonathan A Cook; Matt L Costa
Journal:  Bone Joint J       Date:  2021-01-03       Impact factor: 5.082

3.  The efficacy of rotational control designs in promoting torsional stability of hip fracture fixation.

Authors:  J D Gosiewski; T P Holsgrove; H S Gill
Journal:  Bone Joint Res       Date:  2017-05       Impact factor: 5.853

4.  The tip-apex distance in the X-Bolt dynamic plating system.

Authors:  M A Fernandez; A Aquilina; J Achten; N Parsons; M L Costa; X L Griffin
Journal:  Bone Joint Res       Date:  2017-04       Impact factor: 5.853

5.  Recall of preoperative Oxford Hip and Knee Scores one year after arthroplasty is an alternative and reliable technique when used for a cohort of patients.

Authors:  T F M Yeoman; N D Clement; D Macdonald; M Moran
Journal:  Bone Joint Res       Date:  2018-06-05       Impact factor: 5.853

6.  Randomised controlled trial of the sliding hip screw versus X-Bolt Dynamic Hip Plating System for the fixation of trochanteric fractures of the hip in adults: a protocol study for WHiTE 4 (WHiTE4).

Authors:  Xavier L Griffin; Juul Achten; William Sones; Jonathan Cook; Matthew L Costa
Journal:  BMJ Open       Date:  2018-01-26       Impact factor: 2.692

7.  Baseline quality of life in people with hip fracture: results from the multicentre WHiTE cohort study.

Authors:  Nick R Parsons; Matthew L Costa; Juul Achten; Xavier L Griffin
Journal:  Bone Joint Res       Date:  2020-08-19       Impact factor: 5.853

8.  A randomized controlled trial comparing the Thompson hemiarthroplasty with the Exeter polished tapered stem and Unitrax modular head in the treatment of displaced intracapsular fractures of the hip: the WHiTE 3: HEMI Trial.

Authors:  A L Sims; N Parsons; J Achten; X L Griffin; M L Costa; M R Reed
Journal:  Bone Joint J       Date:  2018-03-01       Impact factor: 5.082

  8 in total