Highly reliable optical system for a rubidium space cold atom clock.

Wei Ren, Yanguang Sun, Bin Wang, Wenbing Xia, Qiuzhi Qu, Jingfeng Xiang, Zuoren Dong, Desheng Lü, Liang Liu.   

Abstract

We describe a highly reliable optical system designed for a rubidium space cold atom clock (SCAC), presenting its design, key technologies, and optical components. All of the optical and electronic components are integrated onto an optimized two-sided 300  mm×290  mm×30  mm optical bench. The compact optical structure and special thermal design ensure that the optical system can pass all of the space environmental qualification tests including both thermal vacuum and mechanical tests. To verify its performance, the optical system is carefully checked before and after each test. The results indicate that this optical system is suitably robust for the space applications for which the rubidium SCAC was built.

Entities:  

Year:  2016        PMID: 27140378     DOI: 10.1364/AO.55.003607

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  1 in total

1.  In-orbit operation of an atomic clock based on laser-cooled 87Rb atoms.

Authors:  Liang Liu; De-Sheng Lü; Wei-Biao Chen; Tang Li; Qiu-Zhi Qu; Bin Wang; Lin Li; Wei Ren; Zuo-Ren Dong; Jian-Bo Zhao; Wen-Bing Xia; Xin Zhao; Jing-Wei Ji; Mei-Feng Ye; Yan-Guang Sun; Yuan-Yuan Yao; Dan Song; Zhao-Gang Liang; Shan-Jiang Hu; Dun-He Yu; Xia Hou; Wei Shi; Hua-Guo Zang; Jing-Feng Xiang; Xiang-Kai Peng; Yu-Zhu Wang
Journal:  Nat Commun       Date:  2018-07-24       Impact factor: 14.919

  1 in total