Literature DB >> 27139375

Evaluation of Perfusion Quantification Methods with Ultrasound Contrast Agents in a Machine-Perfused Pig Liver.

Michalakis Averkiou1, Christina P Keravnou2, Maria Louisa Izamis2, Edward Leen3.   

Abstract

PURPOSE: To evaluate dynamic contrast-enhanced ultrasound (DCEUS) as a tool for measuring blood flow in the macro- and microcirculation of an ex-vivo machine-perfused pig liver and to confirm the ability of DCEUS to accurately detect induced flow rate changes so that it could then be used clinically for monitoring flow changes in liver tumors.
MATERIALS AND METHODS: Bolus injections of contrast agents in the hepatic artery (HA) and portal vein (PV) were administered to 3 machine-perfused pig livers. Flow changes were induced by the pump of the machine perfusion system. The induced flow rates were of clinical relevance (150 - 400 ml/min for HA and 400 - 1400 ml/min for PV). Quantification parameters from time-intensity curves [rise time (RT), mean transit time (MTT), area under the curve (AUC) and peak intensity (PI)] were extracted in order to evaluate whether the induced flow changes were reflected in these parameters.
RESULTS: A linear relationship between the image intensity and the microbubble concentration was confirmed first, while time parameters (RT and MMT) were found to be independent of concentration. The induced flow changes which propagated from the larger vessels to the parenchyma were reflected in the quantification parameters. Specifically, RT, MTT and AUC correlated with flow rate changes.
CONCLUSION: Machine-perfused pig liver is an excellent test bed for DCEUS quantification approaches for the study of the hepatic vascular networks. DCEUS quantification parameters (RT, MTT, and AUC) can measure relative flow changes of about 20 % and above in the liver vasculature. DCEUS quantification is a promising tool for real-time monitoring of the vascular network of tumors. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27139375     DOI: 10.1055/s-0042-104645

Source DB:  PubMed          Journal:  Ultraschall Med        ISSN: 0172-4614            Impact factor:   6.548


  4 in total

1.  Contrast-enhanced ultrasound to ultrasound fusion during microwave ablation: feasibility study in a perfused porcine liver model.

Authors:  Wayne Monsky; Christina Keravnou; Michalakis Averkiou
Journal:  J Ultrasound       Date:  2019-02-27

2.  Contrast-Enhanced Ultrasound to Quantifyc Perfusion in a Machine-Perfused Pig Liver.

Authors:  Melinda Chen; Qian Li; Negin Karimian; Heidi Yeh; Yu Duan; Fermin Fontan; Mohamed M Aburawi; Brian W Anthony; Korkut Uygun; Anthony E Samir
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2018-07

3.  Quantitative Three-Dimensional Dynamic Contrast-Enhanced Ultrasound Imaging: First-In-Human Pilot Study in Patients with Liver Metastases.

Authors:  Ahmed El Kaffas; Rosa Maria Silveira Sigrist; George Fisher; Sunitha Bachawal; Joy Liau; Huaijun Wang; Alexander Karanany; Isabelle Durot; Jarrett Rosenberg; Dimitre Hristov; Jürgen K Willmann
Journal:  Theranostics       Date:  2017-08-23       Impact factor: 11.556

4.  Normalizing tumor microenvironment with nanomedicine and metronomic therapy to improve immunotherapy.

Authors:  Fotios Mpekris; Chrysovalantis Voutouri; Myrofora Panagi; James W Baish; Rakesh K Jain; Triantafyllos Stylianopoulos
Journal:  J Control Release       Date:  2022-03-08       Impact factor: 11.467

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.