Literature DB >> 27135564

Investigation of enteric adenovirus and poliovirus removal by coagulation processes and suitability of bacteriophages MS2 and φX174 as surrogates for those viruses.

N Shirasaki1, T Matsushita2, Y Matsui2, T Marubayashi2, K Murai2.   

Abstract

We evaluated the removal of enteric adenovirus (AdV) type 40 and poliovirus (PV) type 1 by coagulation, using water samples from 13 water sources for drinking water treatment plants in Japan. The behaviors of two widely accepted enteric virus surrogates, bacteriophages MS2 and φX174, were compared with the behaviors of AdV and PV. Coagulation with polyaluminum chloride (PACl, basicity 1.5) removed AdV and PV from virus-spiked source waters: the infectious AdV and PV removal ratios evaluated by means of a plaque-forming-unit method were 0.1-1.4-log10 and 0.5-2.4-log10, respectively. A nonsulfated high-basicity PACl (basicity 2.1) removed infectious AdV and PV more efficiently than did other commercially available PACls (basicity 1.5-2.1), alum, and ferric chloride. The MS2 removal ratios tended to be larger than those of AdV and PV, partly because of differences in the hydrophobicities of the virus particles and the sensitivity of the virus to the virucidal activity of PACl; the differences in removal ratios were not due to differences in the surface charges of the virus particles. MS2, which was more hydrophobic than the other viruses, was inactivated during coagulation with PACl. Therefore, MS2 does not appear to be an appropriate surrogate for AdV and PV during coagulation. In contrast, because φX174, like AdV and PV, was not inactivated during coagulation, and because the hydrophobicity of φX174 was similar to or somewhat lower than the hydrophobicities of AdV and PV, the φX174 removal ratios tended to be similar to or somewhat smaller than those of the enteric viruses. Therefore, φX174 is a potential conservative surrogate for AdV and PV during coagulation. In summary, the surface hydrophobicity of virus particles and the sensitivity of the virus to the virucidal activity of the coagulant are probably important determinants of the efficiency of virus removal during coagulation.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bacteriophage; Coagulation; Electrophoretic mobility; Enteric virus; Hydrophobicity; Virus inactivation

Mesh:

Substances:

Year:  2016        PMID: 27135564     DOI: 10.1016/j.scitotenv.2016.04.090

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  3 in total

Review 1.  Where do we stand to oversee the coronaviruses in aqueous and aerosol environment? Characteristics of transmission and possible curb strategies.

Authors:  Bin Ji; Yaqian Zhao; Abraham Esteve-Núñez; Ranbin Liu; Yang Yang; Ange Nzihou; Yiping Tai; Ting Wei; Cheng Shen; Yan Yang; Baimimng Ren; Xingxing Wang; Ya'e Wang
Journal:  Chem Eng J       Date:  2020-10-27       Impact factor: 13.273

2.  Survival of viral pathogens in animal feed ingredients under transboundary shipping models.

Authors:  Scott A Dee; Fernando V Bauermann; Megan C Niederwerder; Aaron Singrey; Travis Clement; Marcelo de Lima; Craig Long; Gilbert Patterson; Maureen A Sheahan; Ana M M Stoian; Vlad Petrovan; Cassandra K Jones; Jon De Jong; Ju Ji; Gordon D Spronk; Luke Minion; Jane Christopher-Hennings; Jeff J Zimmerman; Raymond R R Rowland; Eric Nelson; Paul Sundberg; Diego G Diel
Journal:  PLoS One       Date:  2018-03-20       Impact factor: 3.240

3.  The novel SARS-CoV-2 pandemic: Possible environmental transmission, detection, persistence and fate during wastewater and water treatment.

Authors:  Sanjeeb Mohapatra; N Gayathri Menon; Gayatree Mohapatra; Lakshmi Pisharody; Aryamav Pattnaik; N Gowri Menon; Prudhvi Lal Bhukya; Manjita Srivastava; Meenakshi Singh; Muneesh Kumar Barman; Karina Yew-Hoong Gin; Suparna Mukherji
Journal:  Sci Total Environ       Date:  2020-10-06       Impact factor: 7.963

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.