Seong-Gil Kim1, Eun-Kyung Kim2. 1. Department of Physical Therapy, Uiduk University, Republic of Korea. 2. Department of Physical Therapy, Seonam University, Republic of Korea.
Abstract
[Purpose] The purpose of this study was to analyze test-retest reliability of an active range of motion test using a manual goniometer by unskilled examiners. [Subjects and Methods] Active range of motion was measured in 30 students attending U university (4 males, 26 females). Range of motion during flexion and extension of the shoulder and hip joints were measured using a manual goniometer. [Results] Flexion and extension of the shoulder joint (ICC=0.906 and ICC=0.808) and (ICC=0.946 and ICC=0. 955) of the hip joint showed excellent reliabilities. [Conclusion] The active range of motion test using a manual goniometer showed very high test-retest reliability in unskilled examiners. When examiners are aware of the method of the test, an objective assessment can be conducted.
[Purpose] The purpose of this study was to analyze test-retest reliability of an active range of motion test using a manual goniometer by unskilled examiners. [Subjects and Methods] Active range of motion was measured in 30 students attending U university (4 males, 26 females). Range of motion during flexion and extension of the shoulder and hip joints were measured using a manual goniometer. [Results] Flexion and extension of the shoulder joint (ICC=0.906 and ICC=0.808) and (ICC=0.946 and ICC=0. 955) of the hip joint showed excellent reliabilities. [Conclusion] The active range of motion test using a manual goniometer showed very high test-retest reliability in unskilled examiners. When examiners are aware of the method of the test, an objective assessment can be conducted.
Entities:
Keywords:
Range of motion; Reliability; Tests and measurement
A proper assessment is as important as appropriate treatment for range of motion disorders.
One of the most common assessment methods among physical therapists is measuring range of
motion (ROM) of the joint using a goniometer1, 2). This method has been used for almost
90 years. Baseline limitation on ROM of a patient can be obtained before treatment, and
changes induced in this motion after therapeutic interventions is easily determined3).Reliability studies on ROM measurement of the joint using goniometer have been studied in
depth, and have shown high reliability. However, most of these studies were conducted by
skilled physical therapists1, 2, 4, 5).Because it takes time for physical therapists to develop their expertise, many patients are
assessed by therapists who have not yet perfected their skills. An objective tool is needed
for unskilled physical therapists that indicates their awareness of use, and should show a
high test-retest reliability over a period of time. If the results by unskilled therapists
show high reliability through the precise understanding of the tool and its measurement
method, the tool can be used more objectively. Therefore, the purpose of this study was to
analyze the reliability of the active ROM test using a manual goniometer conducted by
unskilled therapists.
SUBJECTS AND METHODS
This study was conducted with 30 students (4 males, 26 females) attending U university in K
province. The mean age, height, and weight of the participants were 20.5±1.2 years,
167.8±7.1 cm, and 58.3±9.7 kg, respectively. The selection criteria for the subjects were as
follows: no disease affecting the results of the test and no shoulder or hip joint problems.
Those who were unable to understand the nature of the study were excluded. All subjects
understood the purpose of this study and provided written informed consent prior to
participation in the study in accordance with the ethical standard of the Declaration of
Helsinki.A manual goniometer was used to measure active ROM of flexion and extension of the shoulder
and hip joints; the most common and easily measured joints for ROM. Subjects and examiners
were university students majoring in physical therapy who had little experience using a
goniometer. Groups of two students measured each other’s ROM on subsequent days and all were
informed about the nature of the procedure before the test.Flexion was measured in the supine position with the shoulder and hip at 0 degrees of
abduction, adduction, and rotation, and extension was tested in the prone position with the
shoulder and hip at 0 degrees of abduction, adduction, and rotation6, 7). All measurement
values are reported as mean value ± standard deviation.SPSS for Windows (version 20.0) was used to analyze data. The intra-class correlation
coefficient (ICC) was used to examine the test-retest reliability. The statistical
significance used was α = 0.05.
RESULTS
An ICC of 0.906 was obtained for flexion and that of 0.808 was obtained for extension of
the shoulder joint, which were excellent reliabilities (p<0.05). Similarly, an ICC of
0.946 was obtained for flexion and that of 0.955 for extension of the hip joint, which were
excellent reliabilities (p<0.05) (Table
1).
Table 1.
Test-retest reliabilities of range of motion measurements using
goniometer
The ROM of shoulder and hip are the easiest and most commonly measured An ICC of 0.906 was
obtained for flexion and that of 0.808 was obtained for extension of the shoulder joint.
Similarly, an ICC of 0.946 was obtained for flexion and that of 0.955 was obtained for
extension of the hip joint. The test-retest reliabilities of this study were excellent and
not lower than those in previous studies1, 2, 4, 5).Particularly, the hip joint showed a higher reliability than that in a previous study. Pua
et al. presented that the test by a skilled single examiner with 7 years of clinical
physiotherapy experience showed high reliabilities for flexion (ICC=0.97) and extension
(ICC=0.86) of the hip joint5). This study
showed a higher ICC for extension than that in a previous study. The fact that unskilled
examiners showed a higher reliability proves that ROM can be used to assess joints.Both shoulder and hip joints showed high reliabilities, but the reliability of the shoulder
joint was lower than that of the hip joint. Gajdosik & Bohannon reported that the
test-retest reliability for simple joints is higher than that for multiple joints and the
movement of joints is affected by multiple joints and numerous muscles crossing these
joints3). The shoulder joint has better
mobility but its stability is highly affected by the surrounding muscles because it has a
flat articular surface and may be the reason that the shoulder joint had lower reliability
than the hip joint. However, there is no doubt that the reliabilities of both joints were
excellent.In conclusion, an active ROM test using a manual goniometer even by unskilled examiners
showed very high test-retest reliability. When examiners are aware of the method of the
test, an objective assessment can be conducted. A limitation of this study was that the
measurement was performed only for the shoulder and hip joints, and other joints should be
assessed in future studies.
Authors: Silvio Nussbaumer; Michael Leunig; Julia F Glatthorn; Simone Stauffacher; Hans Gerber; Nicola A Maffiuletti Journal: BMC Musculoskelet Disord Date: 2010-08-31 Impact factor: 2.362
Authors: Suzanne F van Rijn; Elisa L Zwerus; Koen Lm Koenraadt; Wilco Ch Jacobs; Michel Pj van den Bekerom; Denise Eygendaal Journal: Shoulder Elbow Date: 2018-06-03
Authors: Martin Missmann; Katrin Gollner; Andrea Schroll; Michael Pirchl; Vincent Grote; Michael J Fischer Journal: Int J Environ Res Public Health Date: 2022-08-25 Impact factor: 4.614