| Literature DB >> 27130365 |
Sarsvat Patel1, Changquan Calvin Sun2.
Abstract
In this study, we first developed a modernized indentation technique for measuring tablet hardness. This technique is featured by rapid digital image capture, using a calibrated light microscope, and precise area-determination. We then systematically studied effects of key experimental parameters, including indentation force, speed, and holding time, on measured hardness of a very soft material, hydroxypropyl cellulose, and a very hard material, dibasic calcium phosphate, to cover a wide range of material properties. Based on the results, a holding period of 3min at the peak indentation load is recommended to minimize the effect of testing speed on H. Using this method, we show that an exponential decay function well describes the relationship between tablet hardness and porosity for seven commonly used pharmaceutical powders investigated in this work. We propose that H and H at zero porosity may be used to quantify the tablet deformability and powder plasticity, respectively.Entities:
Keywords: Indentation; Plasticity; Powder technology; Tableting
Mesh:
Substances:
Year: 2016 PMID: 27130365 DOI: 10.1016/j.ijpharm.2016.04.068
Source DB: PubMed Journal: Int J Pharm ISSN: 0378-5173 Impact factor: 5.875