Literature DB >> 27130100

Sensitive analytical performance of folding based biosensor using methylene blue tagged aptamers.

Gaëlle Catanante1, Rupesh K Mishra1, Akhtar Hayat2, Jean-Louis Marty1.   

Abstract

This work demonstrates the development of a folding based electrochemical aptasensor using methylene blue (MB) tagged anti-Ochratoxin A (OTA) aptamers. Different aptamer coupling strategies were tested using Hexamethylenediamine, polyethylene glycol, simple adsorption and diazonium coupling mechanism. The best sensitivity was recorded by oxidation of amines using hexamethylenediamine (HDMA) on screen printed carbon electrode (SPCE). To achieve the direct detection of OTA, aptamer conjugated redox probe was used and detection was demonstrated based on the conformational changes in aptamer structure upon OTA sensing. Signaling in this class of sensors arises from changes in electron transfer efficiency upon target-induced changes in the conformation/flexibility of the aptamer probe. These changes can be readily recorded electrochemically. The developed aptasensor is unique in its own mechanism as redox probe tagged aptamer coupling such as MB has never been tried to immobilize using long carbon chain spacers as, addition of spacers would provide more sensitive detection methods. A good dynamic range 0.01-5ng/ml was obtained for OTA with Limit of detection (LOD) 0.01ng/ml and Limit of quantification (LOQ) of 0.03ng/ml respectively. The good reproducibility was recorded with RSD% of 3.75. The obtained straight line equation was y=0.4035x+0.90311, r=0.9976. We believe that the sensor design guidelines outlined here represents a general strategy for developing new folding-based electrochemical aptasensors. The developed aptasensor was extended to screen cocoa samples for OTA contamination. The cocoa samples were extracted and purified using molecular imprinted polymer (MIP) columns. The aptasensor displayed good recovery values in the range 84-85% thus, exhibited the effectiveness of proposed aptasensor for such complex matrices.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Cocoa; DPV; Methylene blue; OTA; Redox probe

Mesh:

Substances:

Year:  2016        PMID: 27130100     DOI: 10.1016/j.talanta.2016.03.004

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  14 in total

Review 1.  A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials.

Authors:  K Yugender Goud; K Koteshwara Reddy; M Satyanarayana; Shekher Kummari; K Vengatajalabathy Gobi
Journal:  Mikrochim Acta       Date:  2019-12-07       Impact factor: 5.833

2.  Disposable Electrochemical Aptasensor Based on Graphene Oxide-DNA Complex as Signal Amplifier towards Ultrasensitive Detection of Ochratoxin A.

Authors:  Yang Hu; Hanyin Xie; Jiaying Hu; Danting Yang
Journal:  Micromachines (Basel)       Date:  2022-05-26       Impact factor: 3.523

Review 3.  Electrochemical Affinity Biosensors Based on Disposable Screen-Printed Electrodes for Detection of Food Allergens.

Authors:  Alina Vasilescu; Gilvanda Nunes; Akhtar Hayat; Usman Latif; Jean-Louis Marty
Journal:  Sensors (Basel)       Date:  2016-11-05       Impact factor: 3.576

4.  Folding-Based Electrochemical Aptasensor for the Determination of β-Lactoglobulin on Poly-L-Lysine Modified Graphite Electrodes.

Authors:  Olaya Amor-Gutiérrez; Giulia Selvolini; M Teresa Fernández-Abedul; Alfredo de la Escosura-Muñiz; Giovanna Marrazza
Journal:  Sensors (Basel)       Date:  2020-04-20       Impact factor: 3.576

Review 5.  Electrochemical Aptasensors for Food and Environmental Safeguarding: A Review.

Authors:  Geetesh Kumar Mishra; Vinay Sharma; Rupesh K Mishra
Journal:  Biosensors (Basel)       Date:  2018-03-23

6.  Structural switching electrochemical DNA aptasensor for the rapid diagnosis of tuberculous meningitis.

Authors:  Ritu Das; Abhijeet Dhiman; Subodh Kumar Mishra; Sagarika Haldar; Neera Sharma; Anjali Bansal; Yusra Ahmad; Amit Kumar; Jaya Sivaswami Tyagi; Tarun Kumar Sharma
Journal:  Int J Nanomedicine       Date:  2019-03-26

7.  Ochratoxin A Detection on Antibody- Immobilized on BSA-Functionalized Gold Electrodes.

Authors:  Mihaela Badea; Laura Floroian; Patrizia Restani; Simona Codruta Aurora Cobzac; Marius Moga
Journal:  PLoS One       Date:  2016-07-28       Impact factor: 3.240

8.  The determination of Ochratoxin A based on the electrochemical aptasensor by carbon aerogels and methylene blue assisted signal amplification.

Authors:  Min Wei; Wenyang Zhang
Journal:  Chem Cent J       Date:  2018-04-25       Impact factor: 4.215

Review 9.  Food Safety Analysis Using Electrochemical Biosensors.

Authors:  Geetesh Kumar Mishra; Abbas Barfidokht; Farshad Tehrani; Rupesh Kumar Mishra
Journal:  Foods       Date:  2018-09-01

10.  A Lateral Flow Strip Based Aptasensor for Detection of Ochratoxin A in Corn Samples.

Authors:  Guilan Zhang; Chao Zhu; Yafei Huang; Jiao Yan; Ailiang Chen
Journal:  Molecules       Date:  2018-01-31       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.