Literature DB >> 27130091

Sensitive determination of total particulate phosphorus and particulate inorganic phosphorus in seawater using liquid waveguide spectrophotometry.

Makoto Ehama1, Fuminori Hashihama2, Shinko Kinouchi2, Jota Kanda2, Hiroaki Saito3.   

Abstract

Determining the total particulate phosphorus (TPP) and particulate inorganic phosphorus (PIP) in oligotrophic oceanic water generally requires the filtration of a large amount of water sample. This paper describes methods that require small filtration volumes for determining the TPP and PIP concentrations. The methods were devised by validating or improving conventional sample processing and by applying highly sensitive liquid waveguide spectrophotometry to the measurements of oxidized or acid-extracted phosphate from TPP and PIP, respectively. The oxidation of TPP was performed by a chemical wet oxidation method using 3% potassium persulfate. The acid extraction of PIP was initially carried out based on the conventional extraction methodology, which requires 1M HCl, followed by the procedure for decreasing acidity. While the conventional procedure for acid removal requires a ten-fold dilution of the 1M HCl extract with purified water, the improved procedure proposed in this study uses 8M NaOH solution for neutralizing 1M HCl extract in order to reduce the dilution effect. An experiment for comparing the absorbances of the phosphate standard dissolved in 0.1M HCl and of that dissolved in a neutralized solution [1M HCl: 8M NaOH=8:1 (v:v)] exhibited a higher absorbance in the neutralized solution. This indicated that the improved procedure completely removed the acid effect, which reduces the sensitivity of the phosphate measurement. Application to an ultraoligotrophic water sample showed that the TPP concentration in a 1075mL-filtered sample was 8.4nM with a coefficient of variation (CV) of 4.3% and the PIP concentration in a 2300mL-filtered sample was 1.3nM with a CV of 6.1%. Based on the detection limit (3nM) of the sensitive phosphate measurement and the ambient TPP and PIP concentrations of the ultraoligotrophic water, the minimum filtration volumes required for the detection of TPP and PIP were estimated to be 15 and 52mL, respectively.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Liquid waveguide spectrophotometry; Particulate inorganic phosphorus; Total particulate phosphorus

Mesh:

Substances:

Year:  2016        PMID: 27130091     DOI: 10.1016/j.talanta.2016.02.058

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  2 in total

1.  Nanomolar phosphate supply and its recycling drive net community production in the subtropical North Pacific.

Authors:  Fuminori Hashihama; Ichiro Yasuda; Aki Kumabe; Mitsuhide Sato; Hiroshi Sasaoka; Yosuke Iida; Takuhei Shiozaki; Hiroaki Saito; Jota Kanda; Ken Furuya; Philip W Boyd; Masao Ishii
Journal:  Nat Commun       Date:  2021-06-08       Impact factor: 14.919

2.  Electrochemical oxidizing digestion using PbO2 electrode for total phosphorus determination in a water sample.

Authors:  Tong Qi; Ziqi Su; Yan Jin; Yuqing Ge; Hui Guo; Hui Zhao; Jiaqiang Xu; Qinghui Jin; Jianlong Zhao
Journal:  RSC Adv       Date:  2018-02-07       Impact factor: 3.361

  2 in total