Static axial push-on and lift-off, and push-on and twist-off experiments were designed and performed to measure the effective, room-temperature coefficient of friction mu for different design femoral prosthesis cone taper joints comprising a universal head on a stem spigot. Alumina and metal heads were tested on metal spigots using either distilled water, Ringer's solution, blood or no lubricant. Complementary push-on and lift-off friction tests of Araldite model joints for subsequent frozen-stress, photoelastic stress analysis were performed at 130 degrees C. It was found that lubricant caused little decrease in the values of the coefficient of friction in prosthesis tapers. The values measured were typically mu = 0.2 for an alumina head on a Co-Cr-Mo or Ti-6Al-4V spigot, mu = 0.15 for a Co-Cr-Mo head on a Co-Cr-Mo or Ti-6Al-4V spigot and mu = 0.13 for a stainless steel head on a stainless steel spigot. For Araldite photoelastic models of an alumina head on a Vitallium spigot, as-cast taper surfaces lubricated with silicone grease gave consistent friction of typically mu = 0.14. The axial displacement of model heads on their spigots were compared with predicted values and previously measured values for prosthesis heads.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2712949     DOI: 10.1243/PIME_PROC_1989_203_003_01

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  6 in total

1.  Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

2.  Modelling changes in modular taper micromechanics due to surgeon assembly technique in total hip arthroplasty.

Authors:  Jonathan A Gustafson; Robin Pourzal; Brett R Levine; Joshua J Jacobs; Hannah J Lundberg
Journal:  Bone Joint J       Date:  2020-07       Impact factor: 5.082

3.  Large-diameter total hip arthroplasty modular heads require greater assembly forces for initial stability.

Authors:  A R MacLeod; N P T Sullivan; M R Whitehouse; H S Gill
Journal:  Bone Joint Res       Date:  2016-08       Impact factor: 5.853

4.  A combined experimental and finite element approach to analyse the fretting mechanism of the head-stem taper junction in total hip replacement.

Authors:  Thom Bitter; Imran Khan; Tim Marriott; Elaine Lovelady; Nico Verdonschot; Dennis Janssen
Journal:  Proc Inst Mech Eng H       Date:  2017-06-09       Impact factor: 1.617

Review 5.  What the Surgeon Can Do to Reduce the Risk of Trunnionosis in Hip Arthroplasty: Recommendations from the Literature.

Authors:  Claude B Rieker; Peter Wahl
Journal:  Materials (Basel)       Date:  2020-04-21       Impact factor: 3.623

6.  In vitro testing for hip head-neck taper tribocorrosion: A review of experimental methods.

Authors:  Christian M Wight; Emil H Schemitsch
Journal:  Proc Inst Mech Eng H       Date:  2022-02-10       Impact factor: 1.617

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.