Literature DB >> 27128585

Comparison of non-stent retriever and stent retriever mechanical thrombectomy devices for the endovascular treatment of acute ischemic stroke.

Kate A Hentschel1, Badih Daou1, Nohra Chalouhi1, Robert M Starke2, Shannon Clark1, Ashish Gandhe3, Pascal Jabbour1, Robert Rosenwasser1, Stavropoula Tjoumakaris1.   

Abstract

OBJECTIVE Mechanical thrombectomy is standard of care for the treatment of acute ischemic stroke. However, limited data are available from assessment of outcomes of FDA-approved devices. The objective of this study is to compare clinical outcomes, efficacy, and safety of non-stent retriever and stent retriever thrombectomy devices. METHODS Between January 2008 and June 2014, 166 patients treated at Jefferson Hospital for Neuroscience for acute ischemic stroke with mechanical thrombectomy using Merci, Penumbra, Solitaire, or Trevo devices were retrospectively reviewed. Primary outcomes included 90-day modified Rankin Scale (mRS) score, recanalization rate (thrombolysis in cerebral infarction [TICI score]), and incidence of symptomatic intracranial hemorrhages (ICHs). Univariate analysis and multivariate logistic regression determined predictors of mRS Score 3-6, mortality, and TICI Score 3. RESULTS A total of 99 patients were treated with non-stent retriever devices (Merci and Penumbra) and 67 with stent retrievers (Solitaire and Trevo). Stent retrievers yielded lower 90-day NIH Stroke Scale scores and higher rates of 90-day mRS scores ≤ 2 (22.54% [non-stent retriever] vs 61.67% [stent retriever]; p < 0.001), TICI Score 2b-3 recanalization rates (79.80% [non-stent retriever] vs 97.01% [stent retriever]; p < 0.001), percentage of parenchyma salvaged, and discharge rates to home/rehabilitation. The overall incidence of ICH was also significantly lower (40.40% [non-stent retriever] vs 13.43% [stent retriever]; p = 0.002), with a trend toward lower 90-day mortality. Use of non-stent retriever devices was an independent predictor of mRS Scores 3-6 (p = 0.002), while use of stent retrievers was an independent predictor of TICI Score 3 (p < 0.001). CONCLUSIONS Stent retriever mechanical thrombectomy devices achieve higher recanalization rates than non-stent retriever devices in acute ischemic stroke with improved clinical and radiographic outcomes and safety.

Entities:  

Keywords:  AIS = acute ischemic stroke; CTP = CT perfusion; DWI = diffusion-weighted imaging; ICH = intracranial hemorrhage; JHN = Jefferson Hospital for Neuroscience; NIHSS = NIH Stroke Scale; TICI = thrombolysis in cerebral infarction; endovascular procedures; interventional neurosurgery; mRS = modified Rankin Scale; stroke; tPA = tissue plasminogen activator; thrombectomy; vascular disorders

Mesh:

Year:  2016        PMID: 27128585     DOI: 10.3171/2016.2.JNS152086

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  8 in total

1.  Outcomes of Stent Retriever versus Aspiration-First Thrombectomy in Ischemic Stroke: A Systematic Review and Meta-Analysis.

Authors:  C O A Tsang; I H W Cheung; K K Lau; W Brinjikji; D F Kallmes; T Krings
Journal:  AJNR Am J Neuroradiol       Date:  2018-10-18       Impact factor: 3.825

2.  Vascular imaging of the spine in the US Medicare population: Catheter and MR angiography volumes from 2004 to 2016.

Authors:  Kofi-Buaku Atsina; Mougnyan Cox; Neda I Sedora Roman; Bryan Pukenas; Laurence Parker; David C Levin; Robert W Hurst
Journal:  Neuroradiol J       Date:  2020-06-12

3.  First-Line A Direct Aspiration First-Pass Technique vs. First-Line Stent Retriever for Acute Ischemic Stroke Therapy: A Meta-Analysis.

Authors:  Kevin Li-Chun Hsieh; Kai-I Chuang; Hsu-Huei Weng; Sho-Jen Cheng; Yu Chiang; Cheng-Yu Chen
Journal:  Front Neurol       Date:  2018-09-25       Impact factor: 4.003

4.  Meta-Analysis of Endovascular Treatment for Acute M2 Occlusion.

Authors:  Chul Ho Kim; Sung-Eun Kim; Jin Pyeong Jeon
Journal:  J Korean Neurosurg Soc       Date:  2019-02-27

5.  Efficacy of Mechanical Thrombectomy using Penumbra ACETM Aspiration Catheter Compared to Stent Retriever SolitaireTM FR in Patients with Acute Ischemic Stroke.

Authors:  Dalibor Sila; Markus Lenski; Maria Vojtková; Mustafa Elgharbawy; František Charvát; Stefan Rath
Journal:  Brain Sci       Date:  2021-04-16

Review 6.  Reperfusion therapy in acute ischemic stroke: dawn of a new era?

Authors:  Sonu Bhaskar; Peter Stanwell; Dennis Cordato; John Attia; Christopher Levi
Journal:  BMC Neurol       Date:  2018-01-16       Impact factor: 2.474

7.  Effectiveness of Trevo stent retriever in acute ischemic stroke: Comparison with Solitaire stent.

Authors:  Ho Jun Yi; Dong Hoon Lee; Sang Uk Kim
Journal:  Medicine (Baltimore)       Date:  2018-05       Impact factor: 1.889

8.  The Wall Apposition Evaluation for a Mechanical Embolus Retrieval Device.

Authors:  Xuelian Gu; Yongxiang Qi; Arthur G Erdman
Journal:  J Healthc Eng       Date:  2018-09-25       Impact factor: 2.682

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.