PURPOSE: The fibrosis score is a new diagnostic score that we have developed to evaluate the function of bleb structures after glaucoma filtration surgery using polarization-sensitive optical coherence tomography (PS-OCT). This study aims to assess the efficacy of the fibrosis score in discriminating nonfunctional from the functional blebs.
METHODS: A total of 20 patients who had undergone glaucoma filtration surgery were imaged at different time periods after surgery using PS-OCT. Birefringence tomography of blebs was obtained from PS-OCT, and the fibrosis score was computed for each patient. The fibrosis score is defined as the area of occupation of high birefringence area in the conjunctiva. The blebs were classified as functional or nonfunctional according to the IOP and the application of medication. The power of the fibrosis score to discriminate nonfunctional blebs from functional blebs was evaluated.
RESULTS: The difference in the mean fibrosis score between the functional and nonfunctional bleb group was statistically significant. The fibrosis score showed good ability to discriminate nonfunctional from functional blebs. The area under the receiver operating characteristic curve was 0.82. The best combination of the sensitivity and specificity was 67% and 100%, respectively, for classifying nonfunctional cases.
CONCLUSIONS: The fibrosis score showed a high ability to discriminate nonfunctional from functional blebs. Polarization-sensitive OCT is a noninvasive technique that provides not only the fibrosis score but also standard structural tomography. It can be a comprehensive tool for longitudinal evaluation after filtration surgery for glaucoma.

Entities:  

Mesh:

Year:  2016        PMID: 27127929     DOI: 10.1167/iovs.15-18178

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  9 in total

Review 1.  Polarization sensitive optical coherence tomography - a review [Invited].

Authors:  Johannes F de Boer; Christoph K Hitzenberger; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2017-02-24       Impact factor: 3.732

2.  Machine-learning based segmentation of the optic nerve head using multi-contrast Jones matrix optical coherence tomography with semi-automatic training dataset generation.

Authors:  Deepa Kasaragod; Shuichi Makita; Young-Joo Hong; Yoshiaki Yasuno
Journal:  Biomed Opt Express       Date:  2018-06-21       Impact factor: 3.732

3.  Relationship between filtering bleb vascularization and surgical outcomes after trabeculectomy: an optical coherence tomography angiography study.

Authors:  Xue Yin; Qinhua Cai; Run Song; Xuefei He; Peirong Lu
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2018-09-12       Impact factor: 3.117

4.  Opto-mechanical characterization of sclera by polarization sensitive optical coherence tomography.

Authors:  Andrew Shin; Joseph Park; Joseph L Demer
Journal:  J Biomech       Date:  2018-03-15       Impact factor: 2.712

5.  Evaluation of Functional Filtering Bleb Using Optical Coherence Tomography Angiography.

Authors:  Je Hyun Seo; Ye An Kim; Keun Heung Park; Young Lee
Journal:  Transl Vis Sci Technol       Date:  2019-05-06       Impact factor: 3.283

6.  Quantitative analysis of functional filtering bleb size using Mask R-CNN.

Authors:  Tao Wang; Lei Zhong; Jing Yuan; Ting Wang; Shiyi Yin; Yi Sun; Xing Liu; Xun Liu; Shiqi Ling
Journal:  Ann Transl Med       Date:  2020-06

7.  Visualization of Anterior Chamber Angle Structures With Scattering- and Polarization-Sensitive Anterior Segment Optical Coherence Tomography.

Authors:  Yuta Ueno; Haruhiro Mori; Keita Kikuchi; Masahiro Yamanari; Tetsuro Oshika
Journal:  Transl Vis Sci Technol       Date:  2021-12-01       Impact factor: 3.283

8.  A model for designing intraocular pressure-regulating glaucoma implants.

Authors:  Inês C F Pereira; Hans M Wyss; Leonard Pinchuk; Henny J M Beckers; Jaap M J den Toonder
Journal:  PLoS One       Date:  2022-09-02       Impact factor: 3.752

9.  Comparison of intensity, phase retardation, and local birefringence images for filtering blebs using polarization-sensitive optical coherence tomography.

Authors:  Shinichi Fukuda; Akari Fujita; Deepa Kasaragod; Simone Beheregaray; Yuta Ueno; Yoshiaki Yasuno; Tetsuro Oshika
Journal:  Sci Rep       Date:  2018-05-14       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.