Shengjie Chen1, Jingxing Li2, Peiqing Dong3. 1. Department of Cardiac Surgery; ; Department of Cardiothoracic Surgery, Affiliated Hospital of Jiangsu University, Zhenjiang 212001, China. 2. Department of Cardiac Surgery; 3. Department of Extracorporeal Circulation, Anzhen Hospital, Capital Medical University, Beijing 100029;
Abstract
PURPOSE: To explore the effect of pulsatile flow in the decellularization process of small blood vessels. METHODS: A total of 30 human umbilical cords were used in the current study. The umbilical cords were flushed with 0.25% trypsin/0.01% EDTA for 30 minutes, followed by treatment with 1% sodium dodecyl sulfate sodium dodecyl sulfate for 3 hours. The effectiveness of decellularization on the umbilical artery wall was analyzed by mechanical analysis. The scaffolds' biocompatibility was observed by co-culture with the human umbilical endothelial cells. RESULTS: The maximum stress of the arteries before and after denuding was 3.55 ± 0.42N and 3.50 ± 0.43N, respectively. Under the pressure of 300 mmHg, 28 pieces of umbilical cords remained intact before and after the flushing, while 2 pieces ruptured under 300 mmHg. There was no significant difference in mechanical properties between flushed and control arteries. Isolated human umbilical endothelial cells grow and spread well on the decellularized umbilical artery scaffolds. CONCLUSIONS: Decellularization by pulsatile flow in human umbilical artery is a convenient, rapid and efficient approach to increase the availability of small caliber blood vessel scaffolds. KEY WORDS: Decellularization; Human umbilical artery; Scaffolds; Small diameter blood vessel; Vascular tissue engineering.
PURPOSE: To explore the effect of pulsatile flow in the decellularization process of small blood vessels. METHODS: A total of 30 human umbilical cords were used in the current study. The umbilical cords were flushed with 0.25% trypsin/0.01% EDTA for 30 minutes, followed by treatment with 1% sodium dodecyl sulfate sodium dodecyl sulfate for 3 hours. The effectiveness of decellularization on the umbilical artery wall was analyzed by mechanical analysis. The scaffolds' biocompatibility was observed by co-culture with the human umbilical endothelial cells. RESULTS: The maximum stress of the arteries before and after denuding was 3.55 ± 0.42N and 3.50 ± 0.43N, respectively. Under the pressure of 300 mmHg, 28 pieces of umbilical cords remained intact before and after the flushing, while 2 pieces ruptured under 300 mmHg. There was no significant difference in mechanical properties between flushed and control arteries. Isolated human umbilical endothelial cells grow and spread well on the decellularized umbilical artery scaffolds. CONCLUSIONS: Decellularization by pulsatile flow in human umbilical artery is a convenient, rapid and efficient approach to increase the availability of small caliber blood vessel scaffolds. KEY WORDS: Decellularization; Human umbilical artery; Scaffolds; Small diameter blood vessel; Vascular tissue engineering.
Authors: Beate Tschoeke; Thomas C Flanagan; Anne Cornelissen; Sabine Koch; Anna Roehl; Marvi Sriharwoko; Jörg S Sachweh; Thomas Gries; Thomas Schmitz-Rode; Stefan Jockenhoevel Journal: Artif Organs Date: 2008-07-21 Impact factor: 3.094
Authors: Markus Hoenicka; Volker R Jacobs; Georgine Huber; Franz-Xaver Schmid; Dietrich E Birnbaum Journal: Biomaterials Date: 2007-11-26 Impact factor: 12.479
Authors: Liqiong Gui; Akihito Muto; Stephen A Chan; Christopher K Breuer; Laura E Niklason Journal: Tissue Eng Part A Date: 2009-09 Impact factor: 3.845
Authors: Patrick J Schaner; Niels D Martin; Thomas N Tulenko; Irving M Shapiro; Nicholas A Tarola; Rhoda F Leichter; R Anthony Carabasi; Paul J Dimuzio Journal: J Vasc Surg Date: 2004-07 Impact factor: 4.268
Authors: Lorenzo Soletti; Yi Hong; Jianjun Guan; John J Stankus; Mohammed S El-Kurdi; William R Wagner; David A Vorp Journal: Acta Biomater Date: 2009-06-18 Impact factor: 8.947