| Literature DB >> 27120608 |
Ioannis A Sakellaris1, Dikaia E Saraga2,3, Corinne Mandin4, Célina Roda5, Serena Fossati6, Yvonne de Kluizenaar7, Paolo Carrer8, Sani Dimitroulopoulou9, Victor G Mihucz10, Tamás Szigeti11, Otto Hänninen12, Eduardo de Oliveira Fernandes13, John G Bartzis14, Philomena M Bluyssen15.
Abstract
Indoor environmental conditions (thermal, noise, light, and indoor air quality) may affect workers' comfort, and consequently their health and well-being, as well as their productivity. This study aimed to assess the relations between perceived indoor environment and occupants' comfort, and to examine the modifying effects of both personal and building characteristics. Within the framework of the European project OFFICAIR, a questionnaire survey was administered to 7441 workers in 167 "modern" office buildings in eight European countries (Finland, France, Greece, Hungary, Italy, The Netherlands, Portugal, and Spain). Occupants assessed indoor environmental quality (IEQ) using both crude IEQ items (satisfaction with thermal comfort, noise, light, and indoor air quality), and detailed items related to indoor environmental parameters (e.g., too hot/cold temperature, humid/dry air, noise inside/outside, natural/artificial light, odor) of their office environment. Ordinal logistic regression analyses were performed to assess the relations between perceived IEQ and occupants' comfort. The highest association with occupants' overall comfort was found for "noise", followed by "air quality", "light" and "thermal" satisfaction. Analysis of detailed parameters revealed that "noise inside the buildings" was highly associated with occupants' overall comfort. "Layout of the offices" was the next parameter highly associated with overall comfort. The relations between IEQ and comfort differed by personal characteristics (gender, age, and the Effort Reward Imbalance index), and building characteristics (office type and building's location). Workplace design should take into account both occupant and the building characteristics in order to provide healthier and more comfortable conditions to their occupants.Entities:
Keywords: comfort; indoor air; indoor environmental quality; layout; light; noise; office buildings; open-plan office spaces; perception; thermal comfort
Mesh:
Year: 2016 PMID: 27120608 PMCID: PMC4881069 DOI: 10.3390/ijerph13050444
Source DB: PubMed Journal: Int J Environ Res Public Health ISSN: 1660-4601 Impact factor: 3.390
List of parameters assessed in the OFFICAIR questionnaire survey.
| Parameter | Questionnaire Item |
|---|---|
| Temperature | Too cold (−3)–Too hot (+3) |
| Air Movement | Draughty (−3)–Still (+3) |
| Air Quality | Humid (−3)–Dry (+3) |
| Light | Natural Light: Unsatisfactory (1)–Satisfactory (7) |
| Noise | Noise from outside the building: Unsatisfactory (1)–Satisfactory (7) |
| Amount of Privacy | Unsatisfactory (1)–Satisfactory (7) |
| Office’s Layout | Do not like at all (1)–Like very much (7) |
| Office’s Decoration | Do not like at all (1)–Like very much (7) |
| Cleanliness | Unsatisfactory (1)–Satisfactory (7) |
| View from the Windows | Do not like at all (1)–Like very much (7) |
| Overall Comfort | Unsatisfactory (1)–Satisfactory (7) |
Distribution of buildings and respondents per country and location area in OFFICAIR study.
| Country | Spain | Greece | Italy | Portugal | Finland | France | Hungary | The Netherlands | Total Sample |
|---|---|---|---|---|---|---|---|---|---|
| Number of Buildings | 20 | 23 | 21 | 19 | 19 | 21 | 24 | 20 | 167 |
| Number of Respondents | 698 | 1020 | 809 | 508 | 793 | 1190 | 1409 | 1014 | 7441 |
| % of Respondents | 9% | 14% | 11% | 7% | 10% | 16% | 19% | 14% | 100% |
| Location Area | South | Central/North | |||||||
| % of Respondents | 41% | 59% | 100% | ||||||
Description of overall comfort and satisfaction with indoor environmental quality (IEQ) and detailed indoor environmental parameters in OFFICAIR study (item-scale: from 1-Dissatisfied to 7-Satisfied).
| Parameters | Number of Respondents | Mean | Standard Error | Confidence Intervals (95%) |
|---|---|---|---|---|
| Overall Comfort | 7366 | 4.74 | 0.02 | 4.70–4.77 |
| Light Overall | 7377 | 4.89 | 0.02 | 4.85–4.92 |
| Thermal Comfort | 7137 | 4.48 | 0.02 | 4.08–4.16 |
| Noise Overall | 7371 | 4.26 | 0.02 | 4.22–4.30 |
| Air Quality Overall | 7178 | 4.12 | 0.02 | 4.08–4.16 |
| Noise Outside the Building | 7378 | 5.61 | 0.02 | 5.57–5.65 |
| Artificial Light | 7392 | 5.03 | 0.02 | 4.99–5.07 |
| Too Cold or Too Hot Temperature | 7047 | 5.00 | 0.03 | 4.95–5.05 |
| Noise from Building Systems | 7368 | 4.97 | 0.02 | 4.92–5.01 |
| Natural Light | 7353 | 4.87 | 0.02 | 4.82–4.92 |
| Cleanliness | 7387 | 4.69 | 0.02 | 4.65–4.73 |
| Smelly or Odorless Air | 7093 | 4.62 | 0.02 | 4.57–4.66 |
| View from the Windows | 6929 | 4.42 | 0.02 | 4.38–4.47 |
| Reflection or Glare | 7377 | 4.42 | 0.02 | 4.38–4.47 |
| Layout | 7394 | 4.30 | 0.02 | 4.26–4.34 |
| Humid or Dry Air | 7040 | 4.16 | 0.03 | 4.11–4.22 |
| Stuffy or Fresh Air | 7071 | 3.91 | 0.02 | 3.88–3.95 |
| Noise within the Building | 7399 | 3.84 | 0.02 | 3.80–4.89 |
| Air Movement | 7388 | 3.75 | 0.03 | 3.70–3.80 |
Association between overall comfort and satisfaction with indoor environmental quality (IEQ) (Model 1) and detailed indoor environmental parameters (Model 2) in OFFICAIR study.
| Variables | Odds Ratios | Confidence Intervals (95%) | |
|---|---|---|---|
| Satisfaction with overall Noise | 2.05 *** | 1.99 | 2.12 |
| Satisfaction with overall Air Quality | 1.56 *** | 1.51 | 1.62 |
| Satisfaction with overall Light | 1.49 *** | 1.44 | 1.53 |
| Satisfaction with overall Thermal comfort | 1.44 *** | 1.40 | 1.48 |
| Noise within the Building | 1.43 *** | 1.39 | 1.47 |
| Layout | 1.41 *** | 1.37 | 1.46 |
| Noise from Building Systems | 1.26 *** | 1.23 | 1.29 |
| Stuffy or Fresh Air | 1.26 *** | 1.21 | 1.30 |
| Natural Light | 1.19 *** | 1.16 | 1.23 |
| Artificial Light | 1.18 *** | 1.14 | 1.22 |
| Too Cold or Too Hot Temperature | 1.15 *** | 1.12 | 1.18 |
| Noise Outside the Building | 1.15 *** | 1.12 | 1.19 |
| Cleanliness | 1.15 *** | 1.11 | 1.18 |
| Reflection or Glare | 1.12 *** | 1.09 | 1.15 |
| Humid or Dry Air | 1.10 *** | 1.08 | 1.12 |
| Smelly or Odorless Air | 1.09 *** | 1.06 | 1.13 |
| View from the Windows | 1.04 ** | 1.01 | 1.07 |
| Air Movement | 1.04 ** | 1.01 | 1.06 |
Results from proportional odds ordinal logistic regression analyses. *** p ≤ 0.001; ** p ≤ 0.01.
Relations between overall comfort and satisfaction with indoor environmental quality (IEQ) (Model 1) and detailed indoor environmental parameters (Model 2) according to individuals’characteristics in OFFICAIR study.
| OR (95% CI) | Gender | Age | ERI | |||||
|---|---|---|---|---|---|---|---|---|
| Women | Men | Under 35 years | 36–45 years | 46–55 years | More than 55 years | Less than or equal to 1 | More than 1 | |
| Noise Overall | 1.97 (1.89–2.06) *** | 2.16 (2.05–2.26) *** | 1.96 (1.85–2.08) *** | 2.02 (1.92–2.13) *** | 2.21 (2.05–2.38) *** | 2.09 (1.90–2.30) *** | 2.04 (1.97–2.11) *** | 1.90 (1.67–2.16) *** |
| Air Quality Overall | 1.54 (1.48–1.61) *** | 1.60 (1.52–1.68) *** | 1.60 (1.50–1.69) *** | 1.55 (1.47–1.63) *** | 1.51 (1.40–1.62) *** | 1.63 (1.48–1.79) *** | 1.56 (1.51–1.62) *** | 1.62 (1.41–1.86) *** |
| Light Overall | 1.46 (1.40–1.52) *** | 1.53 (1.46–1.61) *** | 1.44 (1.36–1.53) *** | 1.53 (1.45–1.60) *** | 1.49 (1.39–1.60) *** | 1.47 (1.34–1.61) *** | 1.50 (1.45– 1.55) *** | 1.36 (1.21–1.53) *** |
| Thermal Comfort | 1.44 (1.38–1.50) *** | 1.45 (1.38–1.52) *** | 1.44 (1.37–1.53) *** | 1.45 (1.38–1.52) *** | 1.41 (1.32–1.51) *** | 1.43 (1.31–1.56) *** | 1.46 (1.41– 1.51) *** | 1.24 (1.10–1.41) *** |
| 0.66 | 0.69 | 0.62 | 0.66 | 0.70 | 0.72 | 0.66 | 0.61 | |
| 3544 | 3330 | 2047 | 2625 | 1411 | 796 | 5932 | 376 | |
| Noise within the Building | 1.41 (1.35–1.47) *** | 1.45 (1.39–1.52) *** | 1.36 (1.29–1.43) *** | 1.42 (1.36–1.49) *** | 1.48 (1.39–1.58) *** | 1.59 (1.45–1.75) *** | 1.42 (1.38–1.47) *** | 1.47 (1.31–1.65) *** |
| Layout | 1.42 (1.34–1.4) *** | 1.42 (1.35–1.49) *** | 1.42 (1.33–1.51) *** | 1.40 (1.33–1.48) *** | 1.43 (1.32–1.54) *** | 1.37 (1.24–1.52) *** | 1.40 (1.35–1.45) *** | 1.41 (1.24–1.61) *** |
| Noise from Building Systems | 1.22 (1.17–1.27) *** | 1.31 (1.26–1.37) *** | 1.24 (1.18–1.31) *** | 1.28 (1.22–1.34) *** | 1.26 (1.18–1.34) *** | 1.28 (1.17–1.39) *** | 1.28 (1.24–1.32) *** | 1.05 (0.95–1.17) (n) |
| Stuffy or Fresh Air | 1.24 (1.18–1.30) *** | 1.29 (1.22–1.36) *** | 1.26 (1.18–1.34) *** | 1.32 (1.25–1.40) *** | 1.22 (1.13–1.32) *** | 1.16 (1.05–1.29) *** | 1.25 (1.21–1.30) *** | 1.27 (1.086–1.47) ** |
| Natural Light | 1.19 (1.150–1.24) *** | 1.19 (1.14–1.24) *** | 1.18 (1.12–1.24) *** | 1.20 (1.15–1.26) *** | 1.20 (1.13–1.29) *** | 1.20 (1.09–1.32) *** | 1.19 (1.15–1.22) *** | 1.26 (1.13–1.40) *** |
| Artificial Light | 1.17 (1.12–1.22) *** | 1.20 (1.14–1.26) *** | 1.17 (1.11–1.24) *** | 1.17 (1.11–1.24) *** | 1.18 (1.09–1.27) *** | 1.17 (1.06–1.30) ** | 1.18 (1.14–1.22) *** | 1.26 (1.11–1.42) *** |
| Too Cold or Too Hot Temperature | 1.14 (1.11–1.18) *** | 1.16 (1.12–1.21) *** | 1.14 (1.09–1.19) *** | 1.19 (1.14–1.24) *** | 1.11 (1.05–1.17) *** | 1.13 (1.05–1.22) *** | 1.15 (1.12–1.18) *** | 1.13 (1.02–1.24) * |
| Noise Outside the Building | 1.16 (1.113–1.21) *** | 1.14 (1.09–1.19) *** | 1.14 (1.08–1.20) *** | 1.15 (1.09–1.20) *** | 1.15 (1.07–1.23) *** | 1.29 (1.16–1.44) *** | 1.15 (1.11–1.18) *** | 1.18 (1.06–1.31) ** |
| Cleanliness | 1.14 (1.10–1.19) *** | 1.16 (1.11–1.22) *** | 1.16 ( 1.09–1.23) *** | 1.10 (1.04–1.15) *** | 1.22 (1.14–1.30) *** | 1.14 (1.04–1.26) ** | 1.14 (1.11–1.18) *** | 1.15 (1.02–1.29) * |
| Reflection or Glare | 1.12 (1.08–1.16) *** | 1.13 (1.08–1.17) *** | 1.09 (1.04–1.15) *** | 1.13 (1.09–1.18) *** | 1.16 (1.09–1.23) *** | 1.07 (0.99–1.17) (n) | 1.12 (1.09–1.16) *** | 1.07 (0.97–1.19) (n) |
| Humid or Dry air | 1.09 (1.06–1.13) *** | 1.11 (1.08–1.15) *** | 1.08 (1.04–1.13) *** | 1.12 (1.08–1.16) *** | 1.07 (1.02–1.12) ** | 1.14 (1.06–1.22) *** | 1.10 (1.08–1.13) *** | 1.04 (0.95–1.14) (n) |
| Smelly or Odorless air | 1.09 (1.05–1.14) *** | 1.09 (1.05–1.15) *** | 1.13 (1.07–1.20) *** | 1.08 (1.03–1.14) ** | 1.08 (1.01–1.15) * | 1.09 (0.99–1.19) (n) | 1.10 (1.06–1.13) *** | 1.07 (0.94–1.21) (n) |
| View from the Windows | 1.03 (0.10–1.08) (n) | 1.05 (1.01–1.09) * | 1.06 (1.01–1.12) * | 1.05 (1.00–1.09) (n) | 1.02 (0.96–1.09) (n) | 1.02 (0.93–1.11) (n) | 1.05 (1.02–1.08) ** | 0.98 (0.88–1.08) (n) |
| Air Movement | 1.03 (0.10–1.06) (n) | 1.05 (1.01–1.08) ** | 1.05 (1.01–1.09) * | 1.03 (0.99–1.07) (n) | 1.03 (0.98–1.08) (n) | 1.01 (0.94–1.08) (n) | 1.03 (1.01–1.06) ** | 1.03 (0.94–1.14) (n) |
| 0.60 | 0.63 | 0.56 | 0.61 | 0.66 | 0.66 | 0.60 | 0.59 | |
| 3122 | 2994 | 1838 | 2347 | 1261 | 670 | 5365 | 331 | |
Results from proportional odds ordinal logistic regression analyses. *** p ≤ 0.001; ** p ≤ 0.01; * p ≤ 0.05; (n) p > 0.05.
Relations between overall comfort and satisfaction with indoor environmental quality (IEQ) (Model 1), and detailed indoor environmental parameters (Model 2) according to building characteristics in OFFICAIR study.
| Variables/Subgroups | Country’s Geographical Location | Office Type | ||||
|---|---|---|---|---|---|---|
| OR (95% CI) | Central/North | South | Private | Shared | Open–Plan | |
| Noise Overall | 2.05 (1.97–2.14) *** | 2.06 (1.95–2.16) *** | 2.16 (1.99–2.34) *** | 2.12 (1.99–2.25) *** | 1.95 (1.86–2.04) *** | |
| Air Quality Overall | 1.61 (1.55–1.68) *** | 1.49 (1.41–1.57) *** | 1.58 (1.47–1.70) *** | 1.55 (1.46–1.64) *** | 1.55 (1.48–1.62) *** | |
| Light Overall | 1.46 (1.41–1.52) *** | 1.54 (1.47–1.62) *** | 1.49 (1.38–1.60) *** | 1.52 (1.43–1.61) *** | 1.49 (1.431– 1.56) *** | |
| Thermal Comfort | 1.44 (1.38–1.49) *** | 1.44 (1.37–1.52) *** | 1.44 (1.34–1.54) *** | 1.50 (1.41–1.58) *** | 1.41 (1.35–1.47) *** | |
| 0.67 | 0.68 | 0.68 | 0.66 | 0.65 | ||
| 4128 | 2751 | 1401 | 2055 | 3333 | ||
| Noise within the Building | 1.40 (1.35–1.45) *** | 1.47 (1.40–1.54) *** | 1.44 (1.35–1.54) *** | 1.33 (1.26–1.40) *** | 1.45 (1.39–1.52) *** | |
| Layout | 1.42 (1.36–1.49) *** | 1.40 (1.32–1.47) *** | 1.28 (1.18–1.39) *** | 1.38 (1.30–1.46) *** | 1.45 (1.38–1.53) *** | |
| Noise from Building Systems | 1.27 (1.23–1.32) *** | 1.26 (1.20–1.31) *** | 1.25 (1.17–1.33) *** | 1.35 (1.28–1.42) *** | 1.24 (1.19–1.29) *** | |
| Stuffy or Fresh Air | 1.25 (1.19–1.31) *** | 1.28 (1.21–1.36) *** | 1.30 (1.20–1.42) *** | 1.24 (1.16–1.32) *** | 1.23 (1.17–1.30) *** | |
| Natural Light | 1.19 (1.15–1.24) *** | 1.19 (1.13–1.24) *** | 1.17 (1.08–1.26) *** | 1.19 (1.13–1.25) *** | 1.19 (1.14–1.24) *** | |
| Artificial Light | 1.18 (1.13–1.23) *** | 1.18 (1.12–1.25) *** | 1.15 (1.07–1.24) *** | 1.18 (1.11–1.26) *** | 1.20 (1.14–1.26) *** | |
| Too Cold or Too Hot Temperature | 1.16 (1.12–1.19) *** | 1.14 (1.10–1.19) *** | 1.19 (1.12–1.26) *** | 1.13 (1.08–1.18) *** | 1.14 (1.11–1.18) *** | |
| Noise Outside the Building | 1.17 (1.13–1.22) *** | 1.11 (1.06–1.17) *** | 1.34 (1.24–1.44) *** | 1.19 (1.13–1.25) *** | 1.07 (1.03–1.12) *** | |
| Cleanliness | 1.16 (1.11–1.21) *** | 1.13 (1.08–1.18) *** | 1.27 (1.17–1.37) *** | 1.13 (1.07–1.19) *** | 1.13 (1.08–1.18) *** | |
| Reflection or Glare | 1.11 (1.07–1.14) *** | 1.14 (1.10–1.19) *** | 1.11 (1.04–1.18) *** | 1.12 (1.07–1.17) *** | 1.13 (1.09–1.18) *** | |
| Humid or Dry air | 1.10 (1.07–1.13) *** | 1.09 (1.05–1.13) *** | 1.07 (1.02–1.12) ** | 1.11 (1.07–1.16) *** | 1.11 (1.07–1.14) *** | |
| Smelly or Odorless Air | 1.08 (1.03–1.1) *** | 1.12 (1.07–1.18) *** | 1.12 (1.03–1.20) ** | 1.08 (1.02–1.14) ** | 1.11 (1.06–1.16) *** | |
| View from the Windows | 1.03 (0.10–1.07) ** | 1.06 (1.01–1.11) * | 1.09 (1.02–1.16) ** | 1.03 (0.98–1.08) (n) | 1.04 (1.00–1.09) * | |
| Air Movement | 1.06 (1.02–1.08) *** | 1.02 (0.98–1.05) (n) | 1.03 (0.98–1.09) (n) | 1.02 (0.98–1.06) (n) | 1.03 (1.00–1.07) * | |
| 0.61 | 0.63 | 0.64 | 0.57 | 0.60 | ||
| 3686 | 2430 | 1258 | 1863 | 2930 | ||
Results from proportional odds ordinal logistic regression analyses. *** p ≤ 0.001; ** p ≤ 0.01; * p ≤ 0.05; (n) p > 0.05.