Literature DB >> 27118353

Evaluation of the Painful Dual Taper Modular Neck Stem Total Hip Arthroplasty: Do They All Require Revision?

Young-Min Kwon1.   

Abstract

Although dual taper modular-neck total hip arthroplasty (THA) design with additional neck-stem modularity has the potential to optimize hip biomechanical parameters by facilitating adjustments of leg length, femoral neck version and offset, there is increasing concern regarding this stem design as a result of the growing numbers of adverse local tissue reactions due to fretting and corrosion at the neck-stem taper junction. Implant factors such as taper cone angle, taper surface roughness, taper contact area, modular neck taper metallurgy, and femoral head size play important roles in influencing extent of taper corrosion. There should be a low threshold to conduct a systematic clinical evaluation of patients with dual-taper modular-neck stem THA using systematic risk stratification algorithms as early recognition and diagnosis will ensure prompt and appropriate treatment. Although specialized tests such as metal ion analysis and cross-sectional imaging modalities such as metal artifact reduction sequence magnetic resonance imaging (MARS MRI) are useful in optimizing clinical decision-making, overreliance on any single investigative tool in the clinical decision-making process for revision surgery should be avoided.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  MARS MRI; adverse local tissue reaction; metal ion levels; modular femoral neck stem; taper corrosion

Mesh:

Substances:

Year:  2016        PMID: 27118353     DOI: 10.1016/j.arth.2016.01.074

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  8 in total

Review 1.  Systemic and local toxicity of metal debris released from hip prostheses: A review of experimental approaches.

Authors:  Divya Rani Bijukumar; Abhijith Segu; Júlio C M Souza; XueJun Li; Mark Barba; Louis G Mercuri; Joshua J Jacobs; Mathew Thoppil Mathew
Journal:  Nanomedicine       Date:  2018-01-12       Impact factor: 5.307

2.  Exchangeable Femoral Neck (Dual-Modular) THA Prostheses Have Poorer Survivorship Than Other Designs: A Nationwide Cohort of 324,108 Patients.

Authors:  Sandrine Colas; Assia Allalou; Antoine Poichotte; Philippe Piriou; Rosemary Dray-Spira; Mahmoud Zureik
Journal:  Clin Orthop Relat Res       Date:  2017-02-13       Impact factor: 4.176

3.  Activity-related Changes in Cobalt Levels in a Total Hip with a Modular Femoral Stem: A Case Report.

Authors:  Michael S Reich; Richard H Walker
Journal:  J Orthop Case Rep       Date:  2018 Jan-Feb

4.  Unexpected varus deformity and concomitant metal ion release and MRI findings of modular-neck hip stems: descriptive RSA study in 75 hips with 8 years' follow-up.

Authors:  Sverrir Kiernan; Bart Kaptein; Carl Flivik; Martin Sundberg; Gunnar Flivik
Journal:  Acta Orthop       Date:  2020-12-10       Impact factor: 3.717

5.  Letter to the Editor on "Disassociation of a Cold-Welded Bimodular Titanium Femoral Stem by Intraoperative Ice Cooling".

Authors:  Brian J McGrory
Journal:  Arthroplast Today       Date:  2020-10-17

6.  Retrieval Findings of Recalled Dual-Taper Hips.

Authors:  Anna Di Laura; Harry S Hothi; Johann Henckel; Young-Min Kwon; John A Skinner; Alister J Hart
Journal:  J Bone Joint Surg Am       Date:  2018-10-03       Impact factor: 5.284

Review 7.  Modular Stems: Advantages and Current Role in Primary Total Hip Arthroplasty.

Authors:  Chan-Woo Park; Seung-Jae Lim; Youn-Soo Park
Journal:  Hip Pelvis       Date:  2018-09-04

8.  Dual-taper modular hip implant: Investigation of 3-dimensional surface scans for component contact, shape, and fit.

Authors:  Nicholas B Frisch; Jonathan R Lynch; Robin Pourzal; Richard F Banglmaier; Craig D Silverton
Journal:  Arthroplast Today       Date:  2018-07-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.