Literature DB >> 27118223

Smartphone Imaging in Ophthalmology: A Comparison with Traditional Methods on the Reproducibility and Usability for Anterior Segment Imaging.

David Zy Chen1, Clement Wt Tan.   

Abstract

INTRODUCTION: This study aimed to determine the reproducibility and usability of anterior segment images taken from a smartphone stabilised on a slit-lamp with those taken from a custom-mounted slit-lamp camera.
MATERIALS AND METHODS: This was a prospective, single- blind comparative digital imaging validation study. Digital photographs of patients with cataract were taken using a smartphone camera (an iPhone 5) on a telescopic mount and a Canon EOS 10D anterior segment camera. Images were graded and compared according to the Lens Opacification Classification System III (LOCS III).
RESULTS: A total of 440 anterior segment images were graded independently by 2 ophthalmologists, 2 residents and 2 medical students. Intraclass correlation (ICC) between the iPhone and anterior segment camera images were fair for nuclear opalescence (NO) and nuclear colour (NC), and excellent for cortical (C) and posterior subcapsular (PSC) (NO: ICC 0.40, 95% CI, 0.16 to 0.57; NC: ICC 0.47, 95% CI, 0.16 to 0.66; C: ICC 0.76, 95% CI, 0.71 to 0.81; PSC: ICC 0.81, 95% CI, 0.76 to 0.85). There was no difference in grader impression of confidence and images usability between both cameras (P = 0.66 and P = 0.58, respectively).
CONCLUSION: Anterior segment images taken from an iPhone have good reproducibility for retro-illuminated images, but fair reproducibility for NO and NC under low light settings. There were no differences in grader confidence and subjective image suitability.

Entities:  

Mesh:

Year:  2016        PMID: 27118223

Source DB:  PubMed          Journal:  Ann Acad Med Singapore        ISSN: 0304-4602            Impact factor:   2.473


  4 in total

1.  Smartphone-Acquired Anterior Segment Images for Deep Learning Prediction of Anterior Chamber Depth: A Proof-of-Concept Study.

Authors:  Chaoxu Qian; Yixing Jiang; Zhi Da Soh; Ganesan Sakthi Selvam; Shuyuan Xiao; Yih-Chung Tham; Xinxing Xu; Yong Liu; Jun Li; Hua Zhong; Ching-Yu Cheng
Journal:  Front Med (Lausanne)       Date:  2022-06-23

2.  A novel approach to anterior segment imaging with smartphones in the COVID-19 era.

Authors:  Sreetama Dutt; Siva S Vadivel; Shanmuganathan Nagarajan; Amrutha Galagali; Josephine S Christy; Anand Sivaraman; Divya Parthasarathy Rao
Journal:  Indian J Ophthalmol       Date:  2021-05       Impact factor: 1.848

3.  Semi-permanent smartphone adapter for microscopes: Design demonstration and workflow testing using a slit-lamp biomicroscope.

Authors:  Chieh-Hung Yen; Guo-Quan Wang; Tommy Y Lin; Chun-Hsiu Liu
Journal:  Taiwan J Ophthalmol       Date:  2019 Apr-Jun

4.  Clinical Observation of Allergic Conjunctival Diseases with Portable and Recordable Slit-Lamp Device.

Authors:  Hiroyuki Yazu; Eisuke Shimizu; Shinri Sato; Naohiko Aketa; Taiichiro Katayama; Ryota Yokoiwa; Yasunori Sato; Kazumi Fukagawa; Yoko Ogawa; Kazuo Tsubota; Hiroshi Fujishima
Journal:  Diagnostics (Basel)       Date:  2021-03-17
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.