Literature DB >> 27113917

The effect of thermal processing on the behaviour of peanut allergen peptide targets used in multiple reaction monitoring mass spectrometry experiments.

R L Sayers1, P E Johnson1, J T Marsh1, P Barran2, H Brown3, E N C Mills1.   

Abstract

Mass spectrometry-based methods offer an alternative means of determining allergens in foods. Whilst targeted methods are likely to offer the most robust approach for detection and quantification, little is known about how food processing may affect the behaviour of peptide targets. A systematic study has been undertaken to investigate the effects of thermal processing (boiling, roasting, frying) on the behaviour of a suite of peanut peptide targets representing the major clinically-relevant allergens. Initially the effect of thermal processing on protein extractability was investigated and a mass spectrometry-compatible buffer identified comprising 50 mM Tris-HCl, pH 8.8 containing 50 mM dithiothreitol and 0.04% (w/v) acid labile detergent which was able to extract 45-100% of protein from raw, boiled, roasted and fried peanuts using sonication at 60 °C. Eight peptide targets were identified including two peptides from each cupin allergen, Ara h1 and Ara h3 and four peptides from the prolamin superfamily allergens Ara h2, 6 and 7. AQUA peptide standards were synthesised and used to undertake multiple-reaction monitoring experiments, giving assay sensitivities of 0.1-30 amoles of peptide on-column (3 : 1 signal : noise), calculated limits of quantification between 96-1343 amoles of peptide on-column and a linear dynamic range of 4-5 orders of magnitude. Absolute quantification of individual peanut allergens in thermally processed samples showed that peptide targets in the cupin allergens were more prone to processing-induced effects than those from Ara h2, 6 and 7. Targets flanked by arginine residues showed greater thermostability. Identification of processing-stable targets, coupled with more efficient extraction procedures and a wide dynamic range, shows that targeted mass spectrometry methods have great potential as an additional method for quantifying peanut allergens in complex food matrices.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27113917     DOI: 10.1039/c6an00359a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  3 in total

1.  An Electrochemical Sensor Based on Gold-Nanocluster-Modified Graphene Screen-Printed Electrodes for the Detection of β-Lactoglobulin in Milk.

Authors:  Jingyi Hong; Yuxian Wang; Liying Zhu; Ling Jiang
Journal:  Sensors (Basel)       Date:  2020-07-16       Impact factor: 3.576

Review 2.  Tree Nuts and Peanuts as a Source of Beneficial Compounds and a Threat for Allergic Consumers: Overview on Methods for Their Detection in Complex Food Products.

Authors:  Anna Luparelli; Ilario Losito; Elisabetta De Angelis; Rosa Pilolli; Francesca Lambertini; Linda Monaci
Journal:  Foods       Date:  2022-03-01

3.  Effects of different thermal processing methods on the structure and allergenicity of peanut allergen Ara h 1.

Authors:  Yang Tian; Huan Rao; Ke Zhang; Sha Tao; Wen-Tong Xue
Journal:  Food Sci Nutr       Date:  2018-07-27       Impact factor: 2.863

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.