Literature DB >> 27113608

Validated Method for Measuring Functional Range of Motion in Patients With Ankle Arthritis.

James Thornton1, Shiraz Sabah2, Neil Segaren2, Nicholas Cullen2, Dishan Singh2, Andrew Goldberg3.   

Abstract

BACKGROUND: Total range of motion between the tibia and the floor is an important outcome measure following ankle surgery. However, there is wide variation in its measurement: from clinical evaluation, to radiographic metrics, and gait analysis. The purpose of this study was to present and validate a simple, standardized technique for measurement of functional total range of motion between the tibia and the floor using a digital goniometer.
METHODS: Institutional review board approval was obtained. Forty-six ankles from 33 participants were recruited into 2 groups: Group 1 (healthy controls) comprised 20 ankles from 10 participants. None had any musculoskeletal or neurologic pathology. Group 2 (ankle osteoarthritis) comprised 25 ankles from 23 patients. Ankle pathology had been treated with ankle arthrodesis (n = 5), total ankle replacement (n = 6), and nonoperative treatment (n = 14). Measurement was performed by 2 testers according to a standardized protocol developed for the Total Ankle Replacement Versus Arthrodesis (TARVA) randomized controlled trial. Intra- and interrater reliability was calculated using intraclass correlation coefficients (ICCs).
RESULTS: Group 1 (healthy controls): the median difference for all measurements within an observer was 1.5 (interquartile range [IQR] 0.7-2.5) degrees, and the intraclass coefficients (ICCs) for inter- and intrarater total ankle range of motion were excellent: 0.95 (95% confidence interval [CI] 0.91-0.97, P < .001) and 0.942 (95% CI 0.859-0.977, P < .001), respectively. Group 2 (ankle osteoarthritis): the median difference for all measurements within an observer was 0.6 (IQR 0.2-1.3) degrees, and the ICCs for inter- and intrarater total ankle range of motion were excellent: 0.99 (95% CI 0.97-1.0), P < .001) and 0.99 (95% CI 0.96-1.0), P < .001), respectively.
CONCLUSION: This technique provided a reliable, standardized method for measurement of total functional range of motion between the tibia and the floor. The technique required no special equipment or training. It provided a valid functional assessment for patients with or without ankle osteoarthritis, including those who had undergone operative treatment. LEVEL OF EVIDENCE: Level II, prospective comparative study.
© The Author(s) 2016.

Entities:  

Keywords:  TARVA; ankle arthritis; ankle fusion; ankle replacement; range of motion

Mesh:

Year:  2016        PMID: 27113608     DOI: 10.1177/1071100716645391

Source DB:  PubMed          Journal:  Foot Ankle Int        ISSN: 1071-1007            Impact factor:   2.827


  3 in total

1.  Intra-examiner reliability of measurements of ankle range of motion using a modified inclinometer: a pilot study.

Authors:  Patricia Tavares; Victoria Landsman; Leslie Wiltshire
Journal:  J Can Chiropr Assoc       Date:  2017-08

2.  The Bologna-Oxford ankle replacement: a case series of clinical and radiological outcomes.

Authors:  Ali Najefi; Karan Malhotra; Oliver Chan; Nicholas Cullen; Andy Goldberg
Journal:  Int Orthop       Date:  2019-06-25       Impact factor: 3.075

3.  Self-Myofascial Release Intervention and Mobile App in Patients With Hemophilic Ankle Arthropathy: Protocol for a Randomized Controlled Trial.

Authors:  Antonio Javier Meroño-Gallut; Rubén Cuesta-Barriuso; Raúl Pérez-Llanes; Elena Donoso-Úbeda; José-Antonio López-Pina
Journal:  JMIR Res Protoc       Date:  2020-07-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.