Literature DB >> 27101433

Acute Lower Gastrointestinal Bleeding: Temporal Factors Associated With Positive Findings on Catheter Angiography After (99m)Tc-Labeled RBC Scanning.

Maggie Chung1, Gregory J Dubel2,3, Richard B Noto2, Don C Yoo2, Grayson L Baird4, Ethan A Prince2,3, Timothy P Murphy2,3, Timothy L Haaga5, Sun Ho Ahn2,3.   

Abstract

OBJECTIVE: The objective of the study was to determine if time to positive (TTP), defined as the time from the start of (99m)Tc-labeled RBC scanning to the appearance of a radionuclide blush (considered to be a positive finding for acute lower gastrointestinal bleeding [LGIB]), and lag time (LT), defined as the time from the appearance of a radionuclide blush to the start of catheter angiography (CA), affected the yield of CA for the detection of acute LGIB.
MATERIALS AND METHODS: TTP and LT were retrospectively evaluated in 120 patients who had positive findings for acute LGIB on (99m)Tc-labeled RBC scanning and subsequently underwent CA for the diagnosis and localization of gastrointestinal bleeding. Two nuclear medicine fellowship-trained radiologists independently reviewed the (99m)Tc-labeled RBC scans. Two fellowship-trained interventional radiologists independently reviewed the angiograms. All data were analyzed using SAS software.
RESULTS: When a TTP threshold of ≤ 9 minutes was used, the sensitivity, specificity, positive predictive value, and negative predictive value for a positive CA study were 92%, 35%, 27%, and 94%, respectively. In addition, the odds of detecting bleeding on CA increased 6.1-fold with a TTP of ≤ 9 minutes relative to a TTP of > 9 minutes (p = 0.020). A significant inverse relationship was found between LT and a positive CA study (p = 0.041).
CONCLUSION: TTP and LT impact the rate of positive CA studies. A TTP threshold of ≤ 9 minutes allows the detection of almost all patients who would benefit from CA for treatment and allows a reduction in unnecessary negative CA studies. The likelihood of positive findings on CA decreases with a delay in the performance of CA.

Entities:  

Keywords:  RBC scan; angiography; gastrointestinal bleeding gastrointestinal hemorrhage; technetium; technetium-99m sulfur colloid

Mesh:

Substances:

Year:  2016        PMID: 27101433     DOI: 10.2214/AJR.15.15380

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  2 in total

1.  Time to Catheter Angiography for Gastrointestinal Bleeding after Prior Positive Investigation Does Not Affect Bleed Identification.

Authors:  Akshaar Brahmbhatt; Pranay Rao; Andrew Cantos; Devang Butani
Journal:  J Clin Imaging Sci       Date:  2020-04-06

2.  Successful Localization of the Source of Hemorrhage in Patient with Post-Whipple Surgery by 99mTc-Labelled Red Blood Cell Scintigraphy.

Authors:  Ahmed Fathala; Alaa Alduraibi; Moheieldin M Abouzied
Journal:  Case Rep Radiol       Date:  2018-08-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.