Literature DB >> 27098052

In vitro micro-physiological immune-competent model of the human skin.

Qasem Ramadan1, Fiona Chia Wan Ting.   

Abstract

Skin allergy, in particular, allergic contact dermatitis and irritant contact dermatitis, are common occupational and environmental health problems affecting the quality of life of a significant proportion of the world population. Since all new ingredients to be incorporated into a product are potential skin allergens, it is essential that these ingredients be first tested for their allergenic potential. However, despite the considerable effort using animal models to understand the underlying mechanism of skin sensitization, to date, the molecular and cellular responses due to skin contact with sensitizers are still not fully understood. To replace animal testing and to improve the prediction of skin sensitization, significant attention has been directed to the use of reconstructed organotypic in vitro models of human skin. Here we describe a miniaturized immune competent in vitro model of human skin based on 3D co-culture of immortalized human keratinocytes (HaCaT) as a model of the epidermis barrier and human leukemic monocyte lymphoma cell line (U937) as a model of human dendritic cells. The biological model was fitted in a microfluidic-based cell culture system that provides a dynamic cellular environment that mimics the in vivo environment of skin. The dynamic perfusion of culture media significantly improved the tight junction formation as evidenced by measuring higher values of TEER compared to static culture. This setting also maintained the high viability of cells over extended periods of time up to 17 days. The perfusion-based culture also allows growth of the cells at the air-liquid interface by exposing the apical side of the cells to air while providing the cell nutrients through a basolateral fluidic compartment. The microsystem has been evaluated to investigate the effect of the chemical and physical (UV irradiation) stimulation on the skin barrier (i.e. the TJ integrity). Three-tiered culture differential stimulation allowed the investigation of the role of the keratinocyte layer as a protection barrier to chemical/biological hazards.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27098052     DOI: 10.1039/c6lc00229c

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  40 in total

Review 1.  Ex Vivo Tumor-on-a-Chip Platforms to Study Intercellular Interactions within the Tumor Microenvironment.

Authors:  Vardhman Kumar; Shyni Varghese
Journal:  Adv Healthc Mater       Date:  2018-12-05       Impact factor: 9.933

2.  A microscale, full-thickness, human skin on a chip assay simulating neutrophil responses to skin infection and antibiotic treatments.

Authors:  Jae Jung Kim; Felix Ellett; Carina N Thomas; Fatemeh Jalali; R Rox Anderson; Daniel Irimia; Adam B Raff
Journal:  Lab Chip       Date:  2019-09-10       Impact factor: 6.799

3.  Rapid Prototyping of Multilayer Microphysiological Systems.

Authors:  Sanjin Hosic; Adam J Bindas; Marissa L Puzan; Will Lake; Jonathan R Soucy; Fanny Zhou; Ryan A Koppes; David T Breault; Shashi K Murthy; Abigail N Koppes
Journal:  ACS Biomater Sci Eng       Date:  2020-06-03

Review 4.  Organ-on-a-chip engineering: Toward bridging the gap between lab and industry.

Authors:  Qasem Ramadan; Mohammed Zourob
Journal:  Biomicrofluidics       Date:  2020-07-14       Impact factor: 2.800

5.  Current advances in skin-on-a-chip models for drug testing.

Authors:  Qiang Zhang; Linda Sito; Mao Mao; Jiankang He; Yu Shrike Zhang; Xin Zhao
Journal:  Microphysiol Syst       Date:  2018-08-30

6.  Organs-on-chips with integrated electrodes for trans-epithelial electrical resistance (TEER) measurements of human epithelial barrier function.

Authors:  Olivier Y F Henry; Remi Villenave; Michael J Cronce; William D Leineweber; Maximilian A Benz; Donald E Ingber
Journal:  Lab Chip       Date:  2017-06-27       Impact factor: 6.799

Review 7.  Next generation human skin constructs as advanced tools for drug development.

Authors:  H E Abaci; Zongyou Guo; Yanne Doucet; Joanna Jacków; Angela Christiano
Journal:  Exp Biol Med (Maywood)       Date:  2017-06-07

Review 8.  A Decade of Organs-on-a-Chip Emulating Human Physiology at the Microscale: A Critical Status Report on Progress in Toxicology and Pharmacology.

Authors:  Mario Rothbauer; Barbara E M Bachmann; Christoph Eilenberger; Sebastian R A Kratz; Sarah Spitz; Gregor Höll; Peter Ertl
Journal:  Micromachines (Basel)       Date:  2021-04-21       Impact factor: 2.891

9.  In-Line Analysis of Organ-on-Chip Systems with Sensors: Integration, Fabrication, Challenges, and Potential.

Authors:  Stefanie Fuchs; Sofia Johansson; Anders Ø Tjell; Gabriel Werr; Torsten Mayr; Maria Tenje
Journal:  ACS Biomater Sci Eng       Date:  2021-06-16

Review 10.  Microphysiological systems for the modeling of wound healing and evaluation of pro-healing therapies.

Authors:  Halston E Deal; Ashley C Brown; Michael A Daniele
Journal:  J Mater Chem B       Date:  2020-08-19       Impact factor: 6.331

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.