The simulation of continuous arteriovenous hemodialysis with a mathematical model.

T L Pallone1, S Hyver, J Petersen.   

Abstract

We have developed a mathematical model that predicts the performance of continuous arteriovenous hemodialysis. Given patient (plasma protein concentration, hematocrit, mean arterial pressure, central venous pressure) and circuit (flow resistance, membrane hydraulic permeability, dialyzer mass transfer coefficient, ultrafiltrate column height, dialysate flow rate) characteristics as inputs, predictions of hydraulic and oncotic pressure distribution, filtration rate, blood flow, total, diffusive, and convective urea clearances are provided. The model was tested by perfusing a circuit with bovine blood under conditions of pure ultrafiltration, zero net ultrafiltration and dialysis, or combined ultrafiltration and dialysis (countercurrent dialysate flow at rates of 10, 20, and 30 ml/min). In order to permit computation, membrane hydraulic permeability and flow resistances were measured. Dialyzer mass transfer coefficient for urea could not be measured directly and so was determined by fitting model predictions to measured urea clearances. For all conditions of operation, a urea mass transfer coefficient of 0.014 cm/min successfully simulated the data. Predictions of blood flow, filtrate generation rate, and circuit pressure distribution were accurate. At lower dialysate flow rates, urea clearance approximated the sum of dialysate flow and filtration rate. At higher dialysate flows, however, departure from this ideal blood-dialysate equilibrium was observed. Model predictions regarding the relative contributions of diffusion and convection to urea clearance were explored. Under conditions of nearly perfect equilibration of urea between blood and dialysate at the blood inlet, the model predicts that the diffusive clearance of urea will increase with increasing rate of filtration and may exceed the rate of dialysate inflow.

Entities:  

Mesh:

Substances:

Year:  1989        PMID: 2709658     DOI: 10.1038/ki.1989.17

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  3 in total

1.  Determinants of Hemodialysis Performance: Modeling Fluid and Solute Transport in Hollow-Fiber Dialyzers.

Authors:  Jian Yu; Vipul C Chitalia; Olukemi O Akintewe; Aurelie Edwards; Joyce Y Wong
Journal:  Regen Eng Transl Med       Date:  2019-11-25

2.  Continuous arteriovenous haemodialysis and haemofiltration in intensive care acute renal failure patients.

Authors:  A A Alarabi; A Taube; B G Danielson; B Wikström
Journal:  Int Urol Nephrol       Date:  1992       Impact factor: 2.370

3.  Continuous arterio-venous haemodiafiltration: hydraulic and diffusive permeability index of an AN-69 capillary haemofilter.

Authors:  E Akcahuseyin; W A van Duyl; H H Vincent; M C Vos; M A Schalekamp
Journal:  Med Biol Eng Comput       Date:  1998-01       Impact factor: 2.602

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.