Literature DB >> 27095898

Impact of different file systems on the amount of apically extruded debris during endodontic retreatment.

Emel Uzunoglu1, Sevinc Aktemur Turker2.   

Abstract

OBJECTIVE: The goal of present study was to determine the effect of different nickel-titanium file systems on the amount of apically extruded debris during endodontic retreatment: D-RaCe retreatment systems, EdgeFile XR retreatment rotary files, and Reciproc R40.
MATERIALS AND METHODS: Thirty-six single-rooted prepared mandibular premolar teeth were filled with Gutta-percha and AH Plus sealer. The teeth were then randomly assigned into three groups (n = 12) for retreatment. The endodontic retreatment was performed as follows: D-RaCe, EdgeFile XR, Reciproc 40. Debris extruded apically during the retreatment was collected into preweighed Eppendorf tubes. An incubator was used to store tubes at 70(°) C for 5 days. The initial weight was subtracted from final weight of the Eppendorf tubes to calculate the weight of the dry extruded debris for each group. The data obtained were evaluated using Welch analysis of variance and Games-Howell post-hoc tests (P < 0.05).
RESULTS: All files resulted in apical extrusion of debris. Reciproc caused significantly less debris extrusion compared to D-RaCe and EdgeFile XR (P < 0.05).
CONCLUSIONS: The findings revealed that during endodontic retreatment, number, and taper of files might have an influence on the amount of apically extruded debris during endodontic retreatment.

Entities:  

Keywords:  Endodontics; nickel–titanium alloy; retreatment

Year:  2016        PMID: 27095898      PMCID: PMC4813437          DOI: 10.4103/1305-7456.178306

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

Endodontic retreatment has to be done completely after ineffective root canal treatment in order to facilitate the proper chemomechanical preparation of the root canal system and to preserve tooth integrity. Endodontic instruments are used with light or medium pressure in apical way during retreatment that necrotic pulp tissues, bacteria, irrigants, or obturation materials might be extruded into the apical area. These apically extruded materials have been considered clinically responsible for flare-up and postoperative inflammation or even failure of apical healing.[12] Endodontic retreatment might be difficult and take longer time than the initial treatment.[3] Manufacturers have been developed special instrument systems, which are used with an engine-driven motor and continuous rotation such as ProTaper Universal Retreatment system (Dentsply Maillefer, Ballaigues, Switzerland), the Mtwo Retreatment system (VDW, Munich, Germany), R-Endo system (Micro-Mega, Besançon, France), and D-RaCe (FKG Dentaire, La Chaux-de-Fonds, Switzerland) in order to promote retreatment procedures.[45] New concepts were introduced in which root canal preparation is completed with different motions. Reciproc is a reciprocating instrumentation system, which includes three sizes of instruments (R25, R40, and R50) to be used according to the initial canal diameter.[6] Root canals could be prepared and cleaned with only one of these Reciproc instruments. This instrument is also advocated for retreatment purposes to remove any residual filling material.[5789] Recently, EdgeFile XR retreatment nickel–titanium (Ni–Ti) rotary files that are made of an annealed heat-treated Ni-Ti alloy brand named Fire-Wire™, have been introduced to the market. The deformation and strength characteristics of metals and metal alloys could be changed with heat treatment. According to manufacturer Fire-Wire™ Ni–Ti yields performance-enhancing durability that provides incredible flexibility, so that XR files will enhance and expedite the endodontic retreatment. System includes four files - R1 (25/0.12), R2 (25/0.08), R3 (25/0.06), R4 (25/0.04) – that are used in crown-down manner. All files have constant taper and parabolic cross section. There are few studies evaluating the amount of apically extruded debris during the removal of root canal filling material using the Reciproc and D-RaCe instruments.[459] Furthermore, no studies have quantitatively assessed the amount of debris extruded apically in the retreatment procedure performed using EdgeFile XR retreatment system. Therefore, the goal of present study was to quantitatively determine the amount of debris extruded apically during the retreatment using the Reciproc, D-RaCe, and EdgeFile XR systems. The null hypothesis was that there would be no difference regarding apically extruded debris during retreatment with these files.

MATERIALS AND METHODS

Thirty-six extracted human mandibular premolars with complete root formation and working lengths (WLs) of approximately 21 mm were selected. Periapical radiographs were taken in the buccolingual and mesiodistal direction in each tooth. Only teeth with single and straight root canal (<10°) according to the Schneider method[10] were included in the study. Specimens in similar dimensions with an initial apical diameter corresponding to a size 15 K-file (Mani Inc., Tochigi, Japan) were selected. To standardize the canal morphology, only roots with oval-shaped canals according to criteria (long/short cross-section diameter ratios of ≥ 2.5, at 5 mm from the apex) that were mentioned previously by De-Deus et al.[11] were selected. A 0.9% saline solution was used to store teeth until use.

Root canal preparation and obturation

For reference point, the buccal cusp edge of each tooth was flattened. Endodontic access cavities were prepared with a diamond bur in a high-speed hand piece. The WL was established as 1 mm shorter than the length of the root. A master apical size 35 with K files (Mani Inc., Tochigi, Japan) was used to prepare root canals by using the balance force technique. Step back technique was performed by using K-files #40–50 (Mani Inc., Tochigi, Japan). Root canals were irrigated with 2 mL of 2.5% NaOCl (Sultan, WA, USA) between each file. The irrigation needle (NaviTip 31-gauge needle; Ultradent, South Jordan, UT, USA) was placed as deep as possible into the canal without resistance until it was 1 mm short of the predetermined WL. On completion of instrumentation, each root canal was irrigated with 10 mL of 17% ethylenediaminetetraacetic acid (Vista Dental Products, Racine, WI, USA) and 10 mL distilled water and then dried with paper points (Diadent, Chungcheongbuk-do, Korea). Master Gutta-percha cones of size #35 and taper 0.02 (Dentsply Maillefer, Ballaigues, Switzerland) were placed into the root canal to the WL. AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) was used as sealer. Additional Gutta-percha cones were placed to the depth at which resistance was met. Mesiodistal and buccolingual radiographs were taken to confirm complete filling. The excess Gutta-percha in the coronal portion was removed with a heated plugger, and the root canal openings of all specimens were sealed with temporary filling material (Cavit; 3M ESPE, Seefeld, Germany). The teeth were stored at 37°C and 100% humidity for 1 week to allow setting of the sealer. Root canal cleaning, shaping, filling, and retreatment procedures were performed by a single operator to avoid inter-operator variability.

Debris collection

A similar experimental model described previously was used for determining extruded debris.[51213] Stoppers were separated from the Eppendorf tubes. An analytical balance (Radwag, Radom, Poland) with an accuracy of 10-4 g. was used to measure the initial weights of the tubes. Three consecutive weights were obtained for each tube, and the mean value was calculated. A hole was created on each stopper. Each tooth was inserted up to the cementoenamel junction, and a 27-gauge needle (Ultradent, South Jordan, UT, USA) was placed alongside the stopper. This acted as a drainage cannula and helped to balance the air pressure inside and outside the tubes. Then, each stopper with the tooth and the needle was attached to its Eppendorf tube, and the tubes were fitted into vials with cyanoacrylate. A rubber-dam sheet was used to prevent leakage of overflowing irrigant and also the root apex shielded from operator during the instrumentation procedure.

Retreatment techniques

The 36 teeth were randomly assigned into three groups with 12 specimens in each group. The groups were arranged according to filling material removal systems, which have been used: Reciproc R40 (VDW, Munich, Germany) EdgeFile XR retreatment rotary files (EdgeEndo, Albuquerque, NM, USA) and D-RaCe retreatment systems (FKG, Dentaire, La Chaux-de-Fonds, Switzerland). Group R40; R40 file was used in a slow in-and-out pecking motion with a 3-mm amplitude limit. Gentle apical pressure was combined with a brushing motion against the lateral walls of the root canal.[14] After three complete pecking movements, the instrument was removed from the canal, and its flutes were cleaned off by insertion into a clean stand with a sponge. Group EdgeFile; R1 (25/0.12), R2 (25/0.08), R3 (25/0.06) and R4 (25/0.04) files were used in crown-down manner with light to medium pressure in apical way, respectively. The sequence was repeated until R4 reaches to WL. Final apical preparation was then performed using the EdgeFile X3-C4 file (size 40/0.06 taper) at a speed of 500 rpm and a torque of 3 Ncm as EdgeFile XR retreatment rotary files. Group D-RaCe; D-RaCe retreatment instruments were used as follows: DR1 (size 30/0.10 taper) at a speed of 1000 rpm and a torque of 1.5 Ncm for the cervical third and the beginning of the middle third and DR2 (size 25/0.04 taper) at a speed of 600 rpm and a torque of 1 Ncm to the WL. The DR2 instrument was used with light apical pressure until the WL was reached. Final apical preparation was performed with the RaCe instrument (size 40/0.04 taper) at a speed of 600 rpm and a torque of 1 Ncm. All instruments were used with a 16:1 contra-angle hand-piece powered by a torque-limited endodontic motor (X-Smart Plus, Dentsply Maillefer, Ballaigues, Switzerland) according to manufacturer instructions. A single experienced operator performed all root canal filling removal protocols. The root filling removal was judged complete when the WL was reached, and no residual filling material was observed in the instrument flutes.[4] No solvent was applied to facilitate material removal in all groups.

Determination of debris amount

When retreatment procedures were completed, 5 mL of distilled water was used to irrigate root canals as a final irrigant. The irrigant was delivered by 5 mL disposable plastic syringes (Ultradent, South Jordan, UT, USA). The irrigation needle (NaviTip 31-gauge needle; Ultradent, South Jordan, UT, USA) was placed as deep as possible into the canal without resistance until it was 1 mm short of the predetermined WL. Then, root canals were dried with paper points (Diadent, Chungcheongbuk-do, Korea), and the teeth were removed from the Eppendorf tubes. All of the tubes were incubated at 70°C for 5 days to evaporate the irrigant in the Eppendorf tubes, before being weighed again.[12] After the incubation period, the tubes were weighed again 3 times. The average of these measurements was considered to be the weight of the tube plus the debris. The difference between pre- and post-treatment weights was calculated, and statistical evaluation was performed using SPSS 21.0 software (SPSS Inc., Chicago, IL, USA). Normality distribution of data was determined by Shapiro–Wilk test. The data obtained were analyzed using Welch analysis of variance (ANOVA) followed by post-hoc Games-Howell tests (P < 0.05).

RESULTS

The mean and the standard deviation values of each experimental group are shown in Table 1. There was a statistically significant difference regarding apically extruded debris among groups depending to Welch ANOVA test (P < 0.05). Pairwise comparison revealed that Reciproc was associated with less apical extruded debris and was statistically different form D-RaCe and EdgeFile XR; P values were 0.01 and 0.043, respectively. Also there was statistically significant difference between D-RaCe and EdgeFile XR groups (P = 0.08).
Table 1

Mean and standard deviation values of apically extruded debris in experimental groups (g)

Mean and standard deviation values of apically extruded debris in experimental groups (g)

DISCUSSION

Apical extrusion of debris, which is one crucial reason of postoperative pain and discomfort,[15] is still unavoidable.[4591213] On the other hand, there are various studies that reported favorable effects of Ni–Ti rotary instruments (either introduced for retreatment or for preparation procedures) compared to conventional techniques on amount of apically extruded debris.[451617] There are less retreatment systems on the market compared to preparation systems. Furthermore there are few studies evaluated these systems effects on the amount of apically extruded debris during endodontic retreatment.[4514161718] Hence, the aim of this study was to evaluate the effect of two retreatment systems (D-RaCe and EdgeFile XR) and one reciprocating single-file system (Reciproc 40) on the amount of apically extruded debris. The Reciproc is made of “M-Wire” and able to prepare canals with only a single instrument and has an identical S-shaped cross-sectional design with sharp cutting edges. R40 file has a tip size 40 with a taper 6% over the first 3 mm. There are controversial results regarding Reciproc files' debris extrusion potential during primary root canal treatments.[12192021] Koçak et al.[12] and De-Deus et al.[19] reported that there was less apically extruded debris with Reciproc, however Bürklein et al.[21] and Bürklein and Schäfer[20] reported that there was more amount of debris extruded apically with Reciproc. There are limited studies that use Reciproc for endodontic retreatment. Reciproc system resulted in more apical debris extrusion than the Mtwo system according to Lu et al.[14] However, Dincer et al.[5] and Silva et al.[9] reported that Reciproc was associated with less debris extrusion when compared with a conventional rotary retreatment system such as ProTaper Universal retreatment system, and Mtwo retreatment system. The result of present study was consistent with these two studies. Reciproc produced significantly less amount of apical extruded debris than the other groups. One possible reason of this result might be the number of files that were used for retreatment; the other one might be the motion kinetics of files.[9] D-RaCe and EdgeFile XR were rotated continuously inside the root canal. D-RaCe was associated with more apical extruded debris compared to other groups. The D-RaCe set consists of two NiTi files – DR1 (30/0.10) and DR2 (25/0.04). Topçuoglu et al.[4] reported that there was no statistical difference between the ProTaper Universal, D-RaCe, and R-Endo retreatment groups. EdgeFile XR retreatment system is composed of four files R1 (25/0.12), R2 (25/0.08), R3 (25/0.06), and R4 (25/0.04), with same apical diameter with different tapers. They are made of an annealed heat-treated Ni–Ti alloy brand named Fire-Wire™. EdgeFile XR system caused less apical extruded debris compared to D-RaCe, even the number of files that were used during retreatment were more than D-RaCe. The alteration of taper and apical diameter between two files of D-RaCe is more prominent, than EdgeFile XR system. This extreme change between files in D-RaCe group might have an impact on apical pressure that was applied to instruments during retreatment. Hence this might result in more apical extruded debris. Instrumentation techniques and the design of the instruments have been shown to be effective on amount of apical debris extrusion.[172223] R40 file was chosen because the apical diameter of the master apical file in the initial canal preparation was size 35 and this was larger than that of the retreatment systems. Therefore, in the present study, supplementary instrumentation was performed using RaCe instrument (40/0.04) and EdgeFile X3-C4 instrument (40/0.06). Marques da Silva et al.[24] reported that supplementary instrumentation performed after the use of ProTaper and D-RaCe retreatment files provided more effective cleaning than the use of only retreatment instruments in the apical third. However, there is no current study evaluating the effect of supplementary instrumentation on apically extruded debris. Distilled water was preferred as an irrigation solution to avoid any possible crystallization of sodium hypochlorite that could change the weight of dentin debris and compromise the reliability of the results.[25] It is important to emphasize that file systems were compared in an experimental model using that collected apically extruded debris from extracted teeth. This technique allows a comparison of the file systems under identical conditions and has been used in many studies previously,[451213202126] but it does have limitations.[25] The main disadvantage of the method is that vital periapical tissues cannot be mimicked. Apical extrusion was not limited, because of the absence of a physical backpressure provided by periapical tissues in vivo.[27] This is an imminent shortcoming of in vitro designs with no periapical resistance; as a result certain degree of caution should be taken when transferring the present results to the clinical situation. Furthermore, this study was limited to teeth with mature root morphology. The observed results should not be generalized to teeth with immature root development and open apices.

CONCLUSION

Within the limitations of this in vitro study, all instrumentation techniques produced debris extrusion. Null hypothesis was rejected, as there were significant differences among all groups regarding apically extruded debris. It can be concluded that properties of file systems (metal alloy, number of files, motion kinetics, taper, apical diameter) might have an impact on amount of apically extruded debris during endodontic retreatment. Further studies are needed to evaluate the novel retreatment system EdgeFile XR retreatment rotary files, which is made from Fire-Wire™.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest
  26 in total

1.  A comparison of weights of debris extruded apically by conventional filing and Canal Master techniques.

Authors:  G L Myers; S Montgomery
Journal:  J Endod       Date:  1991-06       Impact factor: 4.171

2.  Limited ability of three commonly used thermoplasticized gutta-percha techniques in filling oval-shaped canals.

Authors:  Gustavo De-Deus; Claudia Reis; Denise Beznos; Alice Maria Gruetzmacher de Abranches; Tauby Coutinho-Filho; Sidney Paciornik
Journal:  J Endod       Date:  2008-09-19       Impact factor: 4.171

3.  Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems.

Authors:  Sebastian Bürklein; Edgar Schäfer
Journal:  J Endod       Date:  2012-04-06       Impact factor: 4.171

4.  Efficacy of two Ni-Ti systems and hand files for removing gutta-percha from root canals.

Authors:  A Mollo; G Botti; N Prinicipi Goldoni; E Randellini; R Paragliola; M Chazine; H F Ounsi; S Grandini
Journal:  Int Endod J       Date:  2011-08-16       Impact factor: 5.264

5.  Evaluation of debris extruded apically during the removal of root canal filling material using ProTaper, D-RaCe, and R-Endo rotary nickel-titanium retreatment instruments and hand files.

Authors:  Hüseyin Sinan Topçuoğlu; Ahmet Aktı; Öznur Tuncay; Asiye Nur Dinçer; Salih Düzgün; Gamze Topçuoğlu
Journal:  J Endod       Date:  2014-10-16       Impact factor: 4.171

6.  Apically extruded debris and irrigant with two Ni-Ti systems and hand files when removing root fillings: a laboratory study.

Authors:  Y Lu; R Wang; L Zhang; H L Li; Q H Zheng; X D Zhou; D M Huang
Journal:  Int Endod J       Date:  2013-04-08       Impact factor: 5.264

7.  Apically extruded dentin debris by reciprocating single-file and multi-file rotary system.

Authors:  Gustavo De-Deus; Aline Neves; Emmanuel João Silva; Thais Accorsi Mendonça; Caroline Lourenço; Camila Calixto; Edson Jorge Moreira Lima
Journal:  Clin Oral Investig       Date:  2014-06-21       Impact factor: 3.573

8.  Canal blockage and debris extrusion with eight preparation techniques.

Authors:  M A al-Omari; P M Dummer
Journal:  J Endod       Date:  1995-03       Impact factor: 4.171

Review 9.  On the causes of persistent apical periodontitis: a review.

Authors:  P N R Nair
Journal:  Int Endod J       Date:  2006-04       Impact factor: 5.264

10.  Quantitative evaluation of apically extruded debris during root canal instrumentation with ProTaper Universal, ProTaper Next, WaveOne, and self-adjusting file systems.

Authors:  Damla Ozsu; Ertugrul Karatas; Hakan Arslan; Meltem C Topcu
Journal:  Eur J Dent       Date:  2014-10
View more
  10 in total

1.  Reciproc and Reciproc Blue in the removal of bioceramic and resin-based sealers in retreatment procedures.

Authors:  Kaline Romeiro; Andressa de Almeida; Marcely Cassimiro; Luciana Gominho; Eugênia Dantas; Nayane Chagas; Christianne Velozo; Laila Freire; Diana Albuquerque
Journal:  Clin Oral Investig       Date:  2019-05-18       Impact factor: 3.573

2.  Postoperative Pain Following Root Canal Instrumentation Using ProTaper Next or Reciproc in Asymptomatic Molars: A Randomized Controlled Single-Blind Clinical Trial.

Authors:  Patrícia Santos Oliveira; Meire Coelho Ferreira; Natália Gomes Nascimento Paula; Alessandro Dourado Loguercio; Renata Grazziotin-Soares; Gisele Rodrigues da Silva; Helena Cristina Santos da Mata; José Bauer; Ceci Nunes Carvalho
Journal:  J Clin Med       Date:  2022-07-01       Impact factor: 4.964

3.  Postoperative pain after removal of gutta-percha from root canals in endodontic retreatment using rotary or reciprocating instruments: a prospective clinical study.

Authors:  Marc Garcia-Font; F Durán-Sindreu; S Morelló; S Irazusta; F Abella; M Roig; J G Olivieri
Journal:  Clin Oral Investig       Date:  2018-02-02       Impact factor: 3.573

4.  Cleaning Efficacy and Debris Extrusion using XP-Endo Finisher and XP-Endo Finisher R as Supplementary Files during Retreatment: An in Vitro Study.

Authors:  Ekramy Hassan; Marwa Sharaan; Mai Ragab
Journal:  Eur Endod J       Date:  2022-03

5.  Evaluation of Apically Extruded Debris during Root Canal Retreatment Using ProTaper Next and Reciproc in Severely Curved Canals.

Authors:  Giselle Nevares; Kaline Romeiro; Diana Albuquerque; Felipe Xavier; Howard Fogel; Laila Freire; Rodrigo Cunha
Journal:  Iran Endod J       Date:  2017

6.  Effect of Rotary and Reciprocating Instrumentation Motions on Postoperative Pain Incidence in Non-Surgical Endodontic Treatments: A Systematic Review and Meta-Analysis.

Authors:  Behnam Rahbani Nobar; Omid Dianat; Behrad Rahbani Nobar; Armin Shirvani; Nazanin Zargar; Majid Kazem; Patricia Tordik
Journal:  Eur Endod J       Date:  2021-02-02

7.  Effectiveness of different rotary file systems in removing the root canal filling material: A micro-computed tomography study.

Authors:  Esin Özlek; Hüseyin Gündüz
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2021-12-05

8.  Cyclic Fatigue Resistance of Heat-Treated Nickel-Titanium Instruments.

Authors:  Mário Tanomaru-Filho; Camila Galletti Espir; Ana Carolina Venção; Nathaly Macedo-Serrano; Jader Camilo-Pinto; JulianeMaria Guerreiro-Tanomaru
Journal:  Iran Endod J       Date:  2018

9.  Debris Apically Extruded by Two Reciprocating Systems: A Comparative Quantitative Study.

Authors:  Andressa Pinho Amaral; Patrícia Bastos Oliveira Conceição Limongi; Carlos Eduardo Fontana; Alexandre Sigrist De Martin; Carlos Eduardo Da Silveira Bueno; Sérgio Luiz Pinheiro
Journal:  Eur J Dent       Date:  2019-12-31

10.  Apically Extruded Debris following Programmed Over Instrumentation of Curved Canals with Three Nickel Titanium Rotary Instruments.

Authors:  Salwa Daoud Yammine; Edgard Antoine Jabbour
Journal:  Eur J Dent       Date:  2020-08-26
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.