Literature DB >> 27095873

(111)In-pentetreotide uptake in accessory spleen: A potential pitfall in somatostatin receptor scintigraphy.

Yavuz Sami Salihoglu1, Tarik Elri1, Rabiye Uslu Erdemir1, Omer Yazgan2.   

Abstract

Entities:  

Year:  2016        PMID: 27095873      PMCID: PMC4815397          DOI: 10.4103/0972-3919.178341

Source DB:  PubMed          Journal:  Indian J Nucl Med        ISSN: 0974-0244


× No keyword cloud information.
Sir, Accessory spleen is a potential pitfall in radiologic and radionuclide evaluation of oncologic patients which may cause misdiagnosis as left adrenal tumor or metastasis. It is a benign and relatively common splenic anomaly so that seen 16% of the normal population with contrast enhanced abdominal computerized tomography (CT). They mostly localized in splenic hilum, but may be seen in any locations in the abdomen.[1] Accessory spleen may show physiological increased 111In-pentetreotide uptake and mimic malignancy in somatostatin receptor scintigraphy (SRS) as with other imaging techniques. Even though some findings described such as well-defined, homogeneously enhancing, uniform round soft tissue densities smaller than 2 cm that might be meaningful, it is not always possible to make a definitive diagnosis with CT.[23] Herein, we present a 49-year-old female patient with cushing disease underwent transsphenoidal adenomectomy, which was requested SRS with 111In-pentetreotide for suspected ectopic adrenocorticotropic hormone (ACTH) secreting tumor, due to high serum cortisol and ACTH levels during regular postoperative follow-up. SRS was performed after intravenous injection with 6 mCi 111In-pentetreotide (octreoscan) using a dual-headed gamma camera (Symbia S, Siemens, USA) with medium-energy parallel hole collimators. Planar whole body images with thorax and abdomen single-photon emission CT (SPECT) images were obtained at 4 and 24 h. In addition to physiological uptake in liver, spleen, and kidneys, two foci of increased tracer uptakes were detected adjacent to spleen and in the nephrosplenic space [Figure 1]. In the retrospective assessment of concurrent abdomen CT, well demarcated round lesions which were isointense with spleen suggesting accessory spleen were detected. These lesions were matched with the focal increased tracer uptakes on SRS. A selective spleen scintigraphy using 99mTc-labeled heat denatured erythrocytes spleen scintigraphy (SSS) was also performed for correlation. Modified in vitro labeling method was used for SSS. Thirty minutes after the injection of 10.0 mCi (370 MBq) heat-denatured, 99mTc-labeled autologous red blood cells, an abdomen SPECT, and planar images were acquired. It showed two foci of increased uptake due to accessory spleen which was matched with the lesions on SRS.
Figure 1

111In-pentetreotide scintigraphy single-photon emission computed tomography showed two foci of increased uptakes adjacent to spleen (black arrow) and in the nephrosplenic space (white arrow) in (a) (raw image), (b) (coronal slice), and (c) (axial slice). Selective spleen scintigraphy using 99mTc-labeled heat denatured erythrocytes showed two foci of increased uptake which were matched with the lesions on somatostatin receptor scintigraphy and compatible with accessory spleen in (d) (raw image), (e) (coronal slice), and (f) (axial slice)

111In-pentetreotide scintigraphy single-photon emission computed tomography showed two foci of increased uptakes adjacent to spleen (black arrow) and in the nephrosplenic space (white arrow) in (a) (raw image), (b) (coronal slice), and (c) (axial slice). Selective spleen scintigraphy using 99mTc-labeled heat denatured erythrocytes showed two foci of increased uptake which were matched with the lesions on somatostatin receptor scintigraphy and compatible with accessory spleen in (d) (raw image), (e) (coronal slice), and (f) (axial slice) In the literature, majority of the reported cases related with accessory spleen were based on false positive evaluation, especially in splenectomized patients.[34] However, Sels et al. presented that lesions which assessed in favor of accessory spleen on CT and magnetic resonance imaging were shown to be neuroendocrine tumor with tissue biopsy later.[5] In our case, instead of performing histopathological analysis, we verified the increased 111In-pentetreotide uptakes with SSS. Splenic scan with 99mTc-labelled denatured red blood cells is a cost-effective and noninvasive radionuclide imaging method used in detecting ectopic splenic tissues such as accessory spleen and splenosis with high sensitivity and specificity.[67] Detection of the intrapancreatic accessory spleen has been reported using 68Ga-DOTANOC positron emission tomography/CT.[8] In conclusion, one should be aware that it is important to make a definitive diagnosis in the suspicion of accessory spleen in any imaging modalities and suspicious uptakes around the spleen in SRS for an accurate clinical management in patients with malignancies. Since CT is not enough for all cases and histopathological verification of each lesion is not feasible, we recommend SSS as a final diagnostic step in such cases.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest
  8 in total

1.  CT features of the accessory spleen.

Authors:  Koenraad J Mortelé; Bart Mortelé; Stuart G Silverman
Journal:  AJR Am J Roentgenol       Date:  2004-12       Impact factor: 3.959

2.  Tc-99m red blood cell uptake in positive somatostatin receptor scintigraphy by two accessory spleens.

Authors:  Isabel Martínez-Rodríguez; Roberto H Allende; Ignacio Banzo; Remedios Quirce; Julio Jiménez-Bonilla; Aurora Sainz-Esteban; José Manuel Carril
Journal:  Clin Nucl Med       Date:  2006-06       Impact factor: 7.794

3.  Ga-68 octreotate PET/CT and Tc-99m heat-denatured red blood cell SPECT/CT imaging of an intrapancreatic accessory spleen.

Authors:  Thomas W Barber; Andrew Dixon; Marty Smith; Kenneth S K Yap; Victor Kalff
Journal:  J Med Imaging Radiat Oncol       Date:  2015-06-03       Impact factor: 1.735

4.  False-positive somatostatin receptor scintigraphy due to an accessory spleen.

Authors:  R Lebtahi; G Cadiot; J P Marmuse; C Vissuzaine; Y Petegnief; A Courillon-Mallet; D Cattan; M Mignon; D Le Guludec
Journal:  J Nucl Med       Date:  1997-12       Impact factor: 10.057

5.  Intrapancreatic accessory spleen detected by 68Ga DOTANOC PET/CT and 99mTc-colloid SPECT/CT scintigraphy.

Authors:  Angela Collarino; Annemilia del Ciello; Germano Perotti; Vittoria Rufini
Journal:  Clin Nucl Med       Date:  2015-05       Impact factor: 7.794

6.  Pitfall of the accessory spleen.

Authors:  J P Sels; R M Wouters; R Lamers; B H Wolffenbuttel
Journal:  Neth J Med       Date:  2000-04       Impact factor: 1.422

7.  Selective Spleen Scintigraphy in the Evaluation of Accessory Spleen/Splenosis in Splenectomized/Nonsplenectomized Patients and the Contribution of SPECT Imaging.

Authors:  Şeyma Ekmekçi; Reyhan Diz-Küçükkaya; Cüneyt Türkmen; Işık Adalet
Journal:  Mol Imaging Radionucl Ther       Date:  2015-02-05

Review 8.  Splenic anomalies of shape, size, and location: pictorial essay.

Authors:  Adalet Elcin Yildiz; Macit Orhan Ariyurek; Musturay Karcaaltincaba
Journal:  ScientificWorldJournal       Date:  2013-04-21
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.