| Literature DB >> 27095524 |
Ozan Volkan Yurdakul1, Nilgün Mesci2, Yilmaz Çetinkaya3, Duygu Geler Külcü2.
Abstract
BACKGROUND ANDEntities:
Keywords: carpal tunnel syndrome; diagnosis; median-ulnar ratio; musculoskeletal ultrasonography; nerve conduction studies
Year: 2016 PMID: 27095524 PMCID: PMC4960212 DOI: 10.3988/jcn.2016.12.3.289
Source DB: PubMed Journal: J Clin Neurol ISSN: 1738-6586 Impact factor: 3.077
Fig. 1Median nerve cross-sectional area at the level of pisiform bone.
Fig. 2Bifurcated ulnar nerve in Guyon's canal.
Demographic features of two groups
| Control group ( | CTS group ( | ||
|---|---|---|---|
| Age | 45.16±13.11 (25–65) | 46.39±7.19 (29–60) | 0.644 |
| Height (m) | 1.62±0.06 (1.53–1.78) | 1.59±0.08 (1.50–1.79) | 0.062 |
| Weight (kg) | 72.38±13.82 (48–103) | 74.77±14.15 (48–109) | 0.484 |
| BMI (kg/m2) | 27.51±5.60 (16.90–39.10) | 29.56±5.75 (17.63–44.79) | 0.144 |
| Gender (M/F) | 5/32 | 4/27 | 1.000 |
BMI: body mass index, CTS: carpal tunnel syndrome.
Comparison of ultrasonographic values among two groups
| Control group ( | CTS group ( | ||
|---|---|---|---|
| CSApisiform (mm2) | 8.46±1.89 | 13.83±4.43 | 0.001* |
| Swelling ratio | 1.00±0.18 | 1.15±0.29 | 0.001* |
| Palmar bowing (cm) | 0.13±0.07 | 0.17±0.09 | 0.004* |
| CSAulnar (mm2) | 4.86±1.17 | 5.94±1.45 | 0.001* |
| CSApisiform/CSAulnar | 1.88±0.72 | 2.45±0.98 | 0.001* |
*p<0.01.
CSApisiform: median nerve cross-sectional area measured at the level of the pisiform bone, CSAulnar: ulnar nerve cross-sectional area measured at the level of the pisiform bone, CTS: carpal tunnel syndrome.
Fig. 3ROC curve for CSApisiform/CSAulnar. CSAP: median nerve cross-sectional area, CSAU: ulnar nerve cross-sectional area, FPF: false positive fraction, TPF: true positive fraction, ROC: receiver operating characteristic.
Comparison of ultrasonographic measurements among three groups
| Control ( | Sensory affection (S) ( | Sensory+motor affection ( | ||
|---|---|---|---|---|
| CSApisiform (mm2) | 8.46±1.89 | 10.83±2.93 | 15.52±4.26 | 0.001** |
| Swelling ratio | 1.00±0.18 | 1.00±0.25 | 1.24±4.26 | 0.001** |
| Palmar bowing (cm) | 0.13±0.07 | 0.17±0.14 | 0.18±0.04 | 0.013* |
| CSAulnar (mm2) | 4.86±1.47 | 5.74±1.27 | 6.06±1.55 | 0.001** |
| CSApisiform/CSAulnar | 1.88±0.72 | 1.95±0.56 | 2.73±1.06 | 0.001** |
*p<0.05, **p<0.01.
CSApisiform: median nerve cross-sectional area measured at the level of the pisiform bone, CSAulnar: ulnar nerve cross-sectional area measured at the level of the pisiform bone.