A Novel Liquid-Liquid Extraction for the Determination of Nicotine in Tap Water, Wastewater, and Saliva at Trace Levels by GC-MS.

.   

Abstract

Determination of nicotine at trace levels in different matrixes is crucial because of nicotine's strongly addictive property. In this study, a simple and fast analytical method was developed using liquid- liquid extraction with GC-MS. Chloroform was used as an extraction solvent. Different parameters for extraction, such as pH of the solution, types and volumes of extraction and supporter solvents for dispersion, extraction period, and salt type and its amount, were optimized. To improve the precision, naphthalene was used as an internal standard. The calibration plot of nicotine was linear from 0.010 to 2.0 mg/L with a correlation coefficient 0.9996. The LOD and LOQ for nicotine after extraction were 2.6 and 8.8 ng/mL, respectively. Under the optimum conditions, tap water, wastewater, and saliva samples were analyzed for their nicotine content. The spiking experiments yielded satisfactory recoveries of 97.6 ± 3.5, 96.8 ± 1.1, and 85.1 ± 1.3% for tap water, wastewater, and saliva samples, respectively.

Entities:  

Year:  2016        PMID: 27094433     DOI: 10.5740/jaoacint.16-0041

Source DB:  PubMed          Journal:  J AOAC Int        ISSN: 1060-3271            Impact factor:   1.913


  4 in total

1.  Simultaneous determination of selected hormones, endocrine disruptor compounds, and pesticides in water medium at trace levels by GC-MS after dispersive liquid-liquid microextraction.

Authors:  Dotse Selali Chormey; Çağdaş Büyükpınar; Fatma Turak; Okan Tarık Komesli; Sezgin Bakırdere
Journal:  Environ Monit Assess       Date:  2017-05-19       Impact factor: 2.513

2.  Simultaneous determination of iprodione, procymidone, and chlorflurenol in lake water and wastewater matrices by GC-MS after multivariate optimization of binary dispersive liquid-liquid microextraction.

Authors:  Nizamettin Özdoğan; Fatih Kapukıran; Gülşen Mutluoğlu; Dotse Selali Chormey; Sezgin Bakırdere
Journal:  Environ Monit Assess       Date:  2018-09-25       Impact factor: 2.513

3.  A novel liquid-liquid extraction for the determination of naphthalene by GC-MS with deuterated anthracene as internal standard.

Authors:  Sezin Erarpat; Gözde Özzeybek; Dotse Selali Chormey; Fatih Erulaş; Fatma Turak; Sezgin Bakırdere
Journal:  Environ Monit Assess       Date:  2017-09-30       Impact factor: 2.513

Review 4.  Detection of contaminants in water supply: A review on state-of-the-art monitoring technologies and their applications.

Authors:  Syahidah Nurani Zulkifli; Herlina Abdul Rahim; Woei-Jye Lau
Journal:  Sens Actuators B Chem       Date:  2017-09-18       Impact factor: 7.460