Reduction of Periodic Motion Artifacts in Photoplethysmography.

Ralph W C G R Wijshoff, Massimo Mischi, Ronald M Aarts.   

Abstract

Periodic motion artifacts affect photoplethysmography (PPG) signals in activities of daily living (ADL), cardiopulmonary exercise testing (CPX), and cardiopulmonary resuscitation (CPR). This hampers measurement of interbeat intervals (IBIs) and oxygen saturation (SpO 2 ). Our objective was to develop a generic algorithm to remove periodic motion artifacts, recovering artifact-reduced PPG signals for beat-to-beat analysis.
METHODS: The algorithm was retrospectively evaluated on forehead PPG signals measured while walking on a treadmill. The step rate was tracked in a motion reference signal via a second-order generalized integrator with a frequency-locked loop. Two reference signals were compared: sensor motion relative to the skin ( ∆x[n]) measured via self-mixing interferometry and head motion ( av[n] ) measured via accelerometry. The step rate was used in a quadrature harmonic model to estimate the artifacts. Quadrature components need only two coefficients per frequency leading to a short filter and prevent undesired frequency-shifted components in the artifact estimate. Subtracting the estimate from the measured signal reduced the artifacts.
RESULTS: Compared to ∆x[n] , av[n] had a better signal-to-noise ratio and more consistently contained a component at the step rate. Artifact reduction was effective for distinct step rate and pulse rate, since the artifact-reduced signals provided more stable IBI and SpO 2 measurements.
CONCLUSION: Accelerometry provided a more reliable motion reference signal. The proposed algorithm can be of significance for monitoring in ADL, CPX, or CPR, by providing artifact-reduced PPG signals for improved IBI and SpO 2 measurements during periodic motion.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27093308     DOI: 10.1109/TBME.2016.2553060

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  A Hybrid Wavelet-Based Method for the Peak Detection of Photoplethysmography Signals.

Authors:  Suyi Li; Shanqing Jiang; Shan Jiang; Jiang Wu; Wenji Xiong; Shu Diao
Journal:  Comput Math Methods Med       Date:  2017-11-07       Impact factor: 2.238

2.  Wrist-worn optical and chest strap heart rate comparison in a heterogeneous sample of healthy individuals and in coronary artery disease patients.

Authors:  Francesco Sartor; Jos Gelissen; Ralph van Dinther; David Roovers; Gabriele B Papini; Giuseppe Coppola
Journal:  BMC Sports Sci Med Rehabil       Date:  2018-05-31

3.  A Portable, Wireless Photoplethysomography Sensor for Assessing Health of Arteriovenous Fistula Using Class-Weighted Support Vector Machine.

Authors:  Paul C-P Chao; Pei-Yu Chiang; Yung-Hua Kao; Tse-Yi Tu; Chih-Yu Yang; Der-Cherng Tarng; Chin-Long Wey
Journal:  Sensors (Basel)       Date:  2018-11-09       Impact factor: 3.576

4.  Noninvasive Hemoglobin Level Prediction in a Mobile Phone Environment: State of the Art Review and Recommendations.

Authors:  Md Kamrul Hasan; Md Hasanul Aziz; Md Ishrak Islam Zarif; Mahmudul Hasan; Mma Hashem; Shion Guha; Richard R Love; Sheikh Ahamed
Journal:  JMIR Mhealth Uhealth       Date:  2021-04-08       Impact factor: 4.773

5.  New pulse oximetry detection based on the light absorbance ratio as determined from amplitude modulation indexes in the time and frequency domains.

Authors:  Pattana Kainan; Ananta Sinchai; Panwit Tuwanut; Paramote Wardkein
Journal:  Biomed Signal Process Control       Date:  2022-03-11       Impact factor: 5.076

Review 6.  Advances in Photopletysmography Signal Analysis for Biomedical Applications.

Authors:  Jermana L Moraes; Matheus X Rocha; Glauber G Vasconcelos; José E Vasconcelos Filho; Victor Hugo C de Albuquerque; Auzuir R Alexandria
Journal:  Sensors (Basel)       Date:  2018-06-09       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.