Effects of Design Variants in Lower-Limb Prostheses on Gait Synergy.

Mark R Pitkin1.   

Abstract

A lower-limb prosthesis is the mechanical device with which an amputee's residual limb interacts with the walking surface. The pressure and shear forces that affect the residuum due to prosthesis use are the sources of pain, residual-limb skin problems and gait deviations. Direct approaches to reducing these problems include improving fit, alignment technique and socket design as well as increasing cushioning with socket liners. A summary of typical malalignments and their consequences is presented. The malalignments are considered sources of excessive moments applied to the residuum, which simplifies the analysis of a patient's gait. A better design of prosthetic joints could improve prosthetic gait. This article addresses the key mechanical parameter of prosthetic joints, namely the dependence "moment of resistance/angle of deflection." A mathematical model has been developed that links stresses on the residuum in transtibial amputees with the moment of resistance in the prosthetic ankle at the critical gait phases. Analysis of the model yields a substantial decrease in stresses on the residuum during the most demanding, load-bearing phase of stance if the moment of resistance in the ankle is similar to that seen in the biological ankle joint. Gait study shows use of the experimental rolling-joint prosthetic foot more closely simulates normal gait synergy than the SACH foot.

Entities:  

Keywords:  Amputee; Gait; Lower-Limb Prosthetics; Prosthetic Joint

Year:  1997        PMID: 27087763      PMCID: PMC4831900          DOI: 10.1097/00008526-199700930-00005

Source DB:  PubMed          Journal:  J Prosthet Orthot        ISSN: 1040-8800


  31 in total

1.  Interface shear stresses during ambulation with a below-knee prosthetic limb.

Authors:  J E Sanders; C H Daly; E M Burgess
Journal:  J Rehabil Res Dev       Date:  1992

2.  The biomechanics of below-knee prostheses in normal, level, bipedal walking.

Authors:  C W RADCLIFFE
Journal:  Artif Limbs       Date:  1962-06

3.  The major determinants in normal and pathological gait.

Authors:  J B SAUNDERS; V T INMAN; H D EBERHART
Journal:  J Bone Joint Surg Am       Date:  1953-07       Impact factor: 5.284

4.  Relationship between lower limb dynamics and knee joint pain.

Authors:  E L Radin; K H Yang; C Riegger; V L Kish; J J O'Connor
Journal:  J Orthop Res       Date:  1991-05       Impact factor: 3.494

5.  Effect on gait using various prosthetic ankle-foot devices.

Authors:  R W Wirta; R Mason; K Calvo; F L Golbranson
Journal:  J Rehabil Res Dev       Date:  1991

6.  External loading comparisons between able-bodied and below-knee-amputee children during walking.

Authors:  J R Engsberg; A G Lee; J L Patterson; J A Harder
Journal:  Arch Phys Med Rehabil       Date:  1991-08       Impact factor: 3.966

7.  A motor programme for the initiation of forward-oriented movements in humans.

Authors:  P Crenna; C Frigo
Journal:  J Physiol       Date:  1991-06       Impact factor: 5.182

Review 8.  Current concepts in above-knee socket design.

Authors:  J W Michael
Journal:  Instr Course Lect       Date:  1990

9.  A model for prediction of failure in amputation of the lower limb.

Authors:  N Falstie-Jensen; K S Christensen
Journal:  Dan Med Bull       Date:  1990-06

10.  Mechanical Outcomes of a Rolling-Joint Prosthetic Foot and Its Performance in the Dorsiflexion Phase of Transtibial Amputee Gait.

Authors:  Mark R Pitkin
Journal:  J Prosthet Orthot       Date:  1995
View more
  5 in total

1.  Biomechanical evaluation of a prototype foot/ankle prosthesis.

Authors:  P M Quesada; M Pitkin; J Colvin
Journal:  IEEE Trans Rehabil Eng       Date:  2000-03

2.  Amputee locomotion: lower extremity loading using running-specific prostheses.

Authors:  Hiroaki Hobara; Brian S Baum; Hyun-Joon Kwon; Alison Linberg; Erik J Wolf; Ross H Miller; Jae Kun Shim
Journal:  Gait Posture       Date:  2013-08-18       Impact factor: 2.840

3.  Loading Effect of Prosthetic Feet's Anthropomorphicity on Transtibial Osseointegrated Implant.

Authors:  Mark Pitkin; Laurent Frossard
Journal:  Mil Med       Date:  2021-01-25       Impact factor: 1.437

4.  Kinematic and biomimetic assessment of a hydraulic ankle/foot in level ground and camber walking.

Authors:  Xuefei Bai; David Ewins; Andrew D Crocombe; Wei Xu
Journal:  PLoS One       Date:  2017-07-13       Impact factor: 3.240

5.  A biomechanical assessment of hydraulic ankle-foot devices with and without micro-processor control during slope ambulation in trans-femoral amputees.

Authors:  Xuefei Bai; David Ewins; Andrew David Crocombe; Wei Xu
Journal:  PLoS One       Date:  2018-10-05       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.