Preliminary Analysis of Clinical Situations Involved in Quantification of Contrast-Enhanced Ultrasound in Crohn's Disease.

Wenjie Cheng1, Xiang Gao2, Weili Wang1, Min Zhi2, Jian Tang2, Yan-Ling Wen1, Junli Yu1, Yao Chen1, Xiaoyin Liu1, Chuan Yang1, Pinjin Hu2, Guangjian Liu3.   

Abstract

To assess influencing factors for quantitative analysis of contrast-enhanced ultrasound (CEUS) in Crohn's disease (CD), dynamic CEUS examinations from 77 consecutive CD patients were recorded. Peak intensity (PI) values were calculated using the pre-installed quantification software of the ultrasound scanner. The influence of depth, pressure from the ultrasound probe and intraluminal gas was analyzed. The PI value of the anterior wall was lower than that of the posterior wall when the depth was ≤3.4 cm (17.9 dB vs. 21.3 dB; p < 0.05) or evident pressure was exerted (19.1 dB vs. 22.5 dB; p < 0.01). In the presence of intraluminal gas, the PI of the anterior wall was higher than that of the posterior wall (20.7 dB vs. 18.8 dB; p < 0.05). Nevertheless, no significant difference was found between the PI value of anterior and posterior walls when the depth was >3.4 cm (19.8 dB vs. 20.3 dB), moderate pressure was exerted (20.5 dB vs. 21.1 dB) or luminal gas was excluded between the two bowel walls (18.9 dB vs. 21.2 dB; p ≥ 0.05). The factors of depth, pressure from the ultrasound probe and intraluminal gas can affect the quantification results of CEUS. It is preferable to place the region of interest in the posterior wall when luminal gas is absent and in the anterior wall when luminal gas is present. In the latter case, more attention should be paid to reducing pressure by the ultrasound probe.
Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Contrast-enhanced ultrasound; Crohn's disease; Influencing factors; Peak intensity; Quantification; Time intensity curves

Mesh:

Substances:

Year:  2016        PMID: 27087694     DOI: 10.1016/j.ultrasmedbio.2016.03.001

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

1.  Contrast-enhanced ultrasonography in clinical practice in Crohn's disease: feasibility of destruction/replenishment method and software analysis.

Authors:  Andrea Giannetti; Marco Matergi; Marco Biscontri; Luca Franci
Journal:  J Ultrasound       Date:  2017-10-31

2.  Oral exclusive enteral nutrition induces mucosal and transmural healing in patients with Crohn's disease.

Authors:  Jia-Min Chen; Li-Wen He; Ting Yan; Xue-Feng Guo; Pin-Jin Hu; Jun-Sheng Peng; Wen-Jie Cheng; Ling-Ling Li; Qing He
Journal:  Gastroenterol Rep (Oxf)       Date:  2019-01-25
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.