Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation.

Rebecca M Howell1, Eric A Burgett2, Daniel Isaacs2, Samantha G Price Hedrick3, Michael P Reilly3, Leith J Rankine3, Kevin K Grantham3, Stephanie Perkins3, Eric E Klein3.   

Abstract

PURPOSE: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. METHODS AND MATERIALS: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth-dose data to in-air H* (10) values.
RESULTS: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10(6) to 1.04 × 10(7) n/cm(2)/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy.
CONCLUSIONS: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.
Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

Mesh:

Year:  2015        PMID: 27084645     DOI: 10.1016/j.ijrobp.2015.12.356

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Dose Profile Modulation of Proton Minibeam for Clinical Application.

Authors:  Myeongsoo Kim; Ui-Jung Hwang; Kyeongyun Park; Dohyeon Kim; Hak Soo Kim; Sang Hyoun Choi; Jong Hwi Jeong; Dongho Shin; Se Byeong Lee; Joo-Young Kim; Tae Hyun Kim; Hye Jung Baek; Hojin Kim; Kihwan Kim; Sang Soo Kim; Young Kyung Lim
Journal:  Cancers (Basel)       Date:  2022-06-11       Impact factor: 6.575

2.  Peripheral Organ Equivalent Dose Estimation Procedure in Proton Therapy.

Authors:  Carles Domingo; Juan Ignacio Lagares; Maite Romero-Expósito; Beatriz Sánchez-Nieto; Jaime J Nieto-Camero; Jose Antonio Terrón; Leticia Irazola; Alexandru Dasu; Francisco Sánchez-Doblado
Journal:  Front Oncol       Date:  2022-05-25       Impact factor: 5.738

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.