Preprocedural Transthoracic Echocardiography Can Predict Amplatzer Septal Occluder Device Size for Transcatheter Atrial Septal Defect Closure.

Serena P Sah1, Sergio Bartakian1, Howaida El-Said1, Delaram P Molkara1, Beth Printz1, John W Moore1.   

Abstract

OBJECTIVE: To evaluate whether preprocedural transthoracic echocardiography (TTE) can be used to predict Amplatzer septal occluder (ASO) size for device closure of atrial septal defect (ASD).
DESIGN: Retrospective review of patients who underwent ASD device closure at our institution between August 2006 and August 2013 was performed. Patients with complex congenital heart disease, devices other than the ASO, multiple devices, or inadequate TTE images were excluded. Those who had transesophageal echocardiography (TEE)-guided device placement were evaluated. A blinded observer reviewed their preprocedural TTE images and applied a scaled formula to predict device size.
RESULTS: A total of 186 patients underwent ASO placement during the study period, 87 had TEE guidance, of which 45 met inclusion criteria. The mean predicted device size by the scaled formula was 18.0 ± 5.11 mm, compared to the mean implanted device size of 18.8 ± 5.22 mm. The mean absolute difference between each predicted and final deployed device size was 1.44 mm with 95% CI [1.08, 1.81]. The Pearson correlation showed that the predicted device size had a positive correlation coefficient of 0.94.
CONCLUSION: Preprocedural TTE assessment of ASD size using a scaling formula in patients with adequate TTE windows can accurately predict ASO device size and aid in device selection.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Amplatzer Septal Occluder; Atrial Septal Defect; Defect Sizing; Device Closure; Echocardiography

Mesh:

Year:  2016        PMID: 27079542     DOI: 10.1111/chd.12365

Source DB:  PubMed          Journal:  Congenit Heart Dis        ISSN: 1747-079X            Impact factor:   2.007


  3 in total

1.  Feasibility of percutaneous closure of atrial septal defects in adults under transthoracic echocardiography guidance using the Figulla atrial septal defect occluder device.

Authors:  Mahmoud Ali; Hesham Salah El-Din; Sameh Bakhoum; Amal El-Sisi; Kareem Mahmood; Heba Farouk; Hossam Kandil
Journal:  J Saudi Heart Assoc       Date:  2017-04-21

2.  Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases.

Authors:  Qiang Chen; Hua Cao; Gui Can Zhang; Liang Wan Chen; Heng Lu; Lin Li Yu
Journal:  Anatol J Cardiol       Date:  2018-12       Impact factor: 1.596

3.  Spectrum of morphological abnormalities and treatment outcomes in ostium secundum type of atrial septal defects: Single center experience in >500 cases.

Authors:  Ajith Ananthakrishna Pillai; Shabnasri Sinouvassalou; Kabilan S Jagadessan; Hemachandren Munuswamy
Journal:  J Saudi Heart Assoc       Date:  2018-10-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.