Literature DB >> 27079276

A sensitivity metric and software to guide the analysis of soft films measured by a quartz crystal microbalance.

Thomas P McNamara1, Christopher F Blanford1.   

Abstract

This article introduces a set of mathematical and computational tools for use with a quartz crystal microbalance (QCM) to aid in experimental planning and data interpretation. The optimisation tools are based on a metric we term the total parameter matrix sensitivity (TPM-sensitivity). TPM-sensitivity is defined mathematically as the Jacobian determinant of a QCM's responses (e.g., frequency change or dissipation/bandwidth change for a given harmonic) with respect to changes in the physical properties of a soft film and surrounding solution (e.g., density or viscosity). Large TPM-sensitivity values denote conditions where the sensor responses are not only large but also allow the selected unknown physical properties to be mathematically decoupled. In some cases, the viscoelastic properties of an adlayer can be determined using only frequency responses. We validated this method using experimentally obtained data of an ageing adlayer of the enzyme bilirubin oxidase from Myrothecium verrucaria. Fits to these measurements produced more realistic film parameters when responses, including frequency-only combinations, were selected to maximise TPM sensitivity. We provide documented MATLAB code with a graphical user interface to enable other QCM users to employ this analysis. The current software can be applied to any single, homogeneous adlayer that obeys a Kelvin-Voigt viscoelastic model and sits under a semi-infinite Newtonian fluid. Only initial estimates of the film values are required, with the analysis providing guidance and predictions, allowing users to create testable hypothesis and determine the physical changes on the surface rather than have pre-existing values for them.

Entities:  

Year:  2016        PMID: 27079276     DOI: 10.1039/c6an00143b

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  1 in total

1.  In situ viscoelastic properties and chain conformations of heavily hydrated carboxymethyl dextran layers: a comparative study using OWLS and QCM-I chips coated with waveguide material.

Authors:  Andras Saftics; György Aurél Prósz; Barbara Türk; Beatrix Peter; Sándor Kurunczi; Robert Horvath
Journal:  Sci Rep       Date:  2018-08-07       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.