Literature DB >> 27078088

Development of an In Vitro Ocular Platform to Test Contact Lenses.

Chau-Minh Phan1, Hendrik Walther2, Huayi Gao3, Jordan Rossy2, Lakshman N Subbaraman2, Lyndon Jones2.   

Abstract

Currently, in vitro evaluations of contact lenses (CLs) for drug delivery are typically performed in large volume vials, which fail to mimic physiological tear volumes. The traditional model also lacks the natural tear flow component and the blinking reflex, both of which are defining factors of the ocular environment. The development of a novel model is described in this study, which consists of a unique 2-piece design, eyeball and eyelid piece, capable of mimicking physiological tear volume. The models are created from 3-D printed molds (Polytetrafluoroethylene or Teflon molds), which can be used to generate eye models from various polymers, such as polydimethylsiloxane (PDMS) and agar. Further modifications to the eye pieces, such as the integration of an explanted human or animal cornea or human corneal construct, will permit for more complex in vitro ocular studies. A commercial microfluidic syringe pump is integrated with the platform to emulate physiological tear secretion. Air exposure and mechanical wear are achieved using two mechanical actuators, of which one moves the eyelid piece laterally, and the other moves the eyeballeyepiece circularly. The model has been used to evaluate CLs for drug delivery and deposition of tear components on CLs.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27078088      PMCID: PMC4841367          DOI: 10.3791/53907

Source DB:  PubMed          Journal:  J Vis Exp        ISSN: 1940-087X            Impact factor:   1.355


  24 in total

1.  Extended drug delivery by contact lenses for glaucoma therapy.

Authors:  Cheng-Chun Peng; Michael T Burke; Blanca E Carbia; Caryn Plummer; Anuj Chauhan
Journal:  J Control Release       Date:  2012-06-18       Impact factor: 9.776

2.  In vitro and in vivo evaluation of novel ciprofloxacin-releasing silicone hydrogel contact lenses.

Authors:  Alex Hui; Mark Willcox; Lyndon Jones
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-07-15       Impact factor: 4.799

3.  A simplified technique for in situ excision of cornea and evisceration of retinal tissue from human ocular globe.

Authors:  Mohit Parekh; Stefano Ferrari; Enzo Di Iorio; Vanessa Barbaro; Davide Camposampiero; Marianthi Karali; Diego Ponzin; Gianni Salvalaio
Journal:  J Vis Exp       Date:  2012-06-12       Impact factor: 1.355

4.  Adjusting biomaterial composition to achieve controlled multiple-day release of dexamethasone from an extended-wear silicone hydrogel contact lens.

Authors:  James C Kaczmarek; Arianna Tieppo; Charles J White; Mark E Byrne
Journal:  J Biomater Sci Polym Ed       Date:  2013-09-27       Impact factor: 3.517

5.  In vitro controlled release of an anti-inflammatory from daily disposable therapeutic contact lenses under physiological ocular tear flow.

Authors:  Arianna Tieppo; Kayla M Pate; Mark E Byrne
Journal:  Eur J Pharm Biopharm       Date:  2012-02-07       Impact factor: 5.571

6.  Extended delivery of hydrophilic drugs from silicone-hydrogel contact lenses containing vitamin E diffusion barriers.

Authors:  Cheng-Chun Peng; Jinah Kim; Anuj Chauhan
Journal:  Biomaterials       Date:  2010-02-13       Impact factor: 12.479

7.  Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model.

Authors:  Magdalena Bajgrowicz; Chau-Minh Phan; Lakshman N Subbaraman; Lyndon Jones
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-04       Impact factor: 4.799

8.  Localization of lysozyme sorption to conventional and silicone hydrogel contact lenses using confocal microscopy.

Authors:  Doerte Luensmann; Feng Zhang; Lakshman Subbaraman; Heather Sheardown; Lyndon Jones
Journal:  Curr Eye Res       Date:  2009-08       Impact factor: 2.424

9.  The impact of tear film components on in vitro lipid uptake.

Authors:  Holly Lorentz; Miriam Heynen; Diana Trieu; Sarah J Hagedorn; Lyndon Jones
Journal:  Optom Vis Sci       Date:  2012-06       Impact factor: 1.973

10.  The impact of intermittent air exposure on lipid deposition.

Authors:  Holly Lorentz; Miriam Heynen; Warda Khan; Diana Trieu; Lyndon Jones
Journal:  Optom Vis Sci       Date:  2012-11       Impact factor: 1.973

View more
  6 in total

1.  Development of an Eye Model With a Physiological Blink Mechanism.

Authors:  Chau-Min Phan; Hendri Walther; Ha Qiao; Ra Shinde; Lyndo Jones
Journal:  Transl Vis Sci Technol       Date:  2019-09-03       Impact factor: 3.283

2.  Release of Moxifloxacin from Contact Lenses Using an In Vitro Eye Model: Impact of Artificial Tear Fluid Composition and Mechanical Rubbing.

Authors:  Chau-Minh Phan; Magdalena Bajgrowicz-Cieslak; Lakshman N Subbaraman; Lyndon Jones
Journal:  Transl Vis Sci Technol       Date:  2016-11-08       Impact factor: 3.283

3.  Development of an In Vitro Blink Model for Ophthalmic Drug Delivery.

Authors:  Chau-Minh Phan; Manish Shukla; Hendrik Walther; Miriam Heynen; David Suh; Lyndon Jones
Journal:  Pharmaceutics       Date:  2021-02-25       Impact factor: 6.321

Review 4.  Biomechanical analysis of ocular diseases and its in vitro study methods.

Authors:  Yali Zhao; Guohuang Hu; Yuwei Yan; Zhen Wang; Xiaohua Liu; Huanhuan Shi
Journal:  Biomed Eng Online       Date:  2022-07-23       Impact factor: 3.903

5.  Differential Deposition of Fluorescently Tagged Cholesterol on Commercial Contact Lenses Using a Novel In Vitro Eye Model.

Authors:  Hendrik Walther; Chau-Minh Phan; Lakshman N Subbaraman; Lyndon Jones
Journal:  Transl Vis Sci Technol       Date:  2018-04-05       Impact factor: 3.283

6.  Cyclosporine Lipid Nanocapsules as Thermoresponsive Gel for Dry Eye Management: Promising Corneal Mucoadhesion, Biodistribution and Preclinical Efficacy in Rabbits.

Authors:  Lubna M Eldesouky; Riham M El-Moslemany; Alyaa A Ramadan; Mahmoud H Morsi; Nawal M Khalafallah
Journal:  Pharmaceutics       Date:  2021-03-09       Impact factor: 6.321

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.