The Effect of Magnetic Field on Positron Range and Spatial Resolution in an Integrated Whole-Body Time-Of-Flight PET/MRI System.

Shih-Ying Huang1, Dragana Savic1, Jaewon Yang1, Uttam Shrestha1, Youngho Seo1.   

Abstract

Simultaneous imaging systems combining positron emission tomography (PET) and magnetic resonance imaging (MRI) have been actively investigated. A PET/MR imaging system (GE Healthcare) comprised of a time-of-flight (TOF) PET system utilizing silicon photomultipliers (SiPMs) and 3-tesla (3T) MRI was recently installed at our institution. The small-ring (60 cm diameter) TOF PET subsystem of this PET/MRI system can generate images with higher spatial resolution compared with conventional PET systems. We have examined theoretically and experimentally the effect of uniform magnetic fields on the spatial resolution for high-energy positron emitters. Positron emitters including 18F, 124I, and 68Ga were simulated in water using the Geant4 Monte Carlo toolkit in the presence of a uniform magnetic field (0, 3, and 7 Tesla). The positron annihilation position was tracked to determine the 3D spatial distribution of the 511-keV gammy ray emission. The full-width at tenth maximum (FWTM) of the positron point spread function (PSF) was determined. Experimentally, 18F and 68Ga line source phantoms in air and water were imaged with an investigational PET/MRI system and a PET/CT system to investigate the effect of magnetic field on the spatial resolution of PET. The full-width half maximum (FWHM) of the line spread function (LSF) from the line source was determined as the system spatial resolution. Simulations and experimental results show that the in-plane spatial resolution was slightly improved at field strength as low as 3 Tesla, especially when resolving signal from high-energy positron emitters in the air-tissue boundary.

Entities:  

Year:  2014        PMID: 27076778      PMCID: PMC4828037          DOI: 10.1109/NSSMIC.2014.7431006

Source DB:  PubMed          Journal:  IEEE Nucl Sci Symp Conf Rec (1997)        ISSN: 1095-7863


  2 in total

1.  Calculation of positron range and its effect on the fundamental limit of positron emission tomography system spatial resolution.

Authors:  C S Levin; E J Hoffman
Journal:  Phys Med Biol       Date:  1999-03       Impact factor: 3.609

2.  Effects of magnetic fields of up to 9.4 T on resolution and contrast of PET images as measured with an MR-BrainPET.

Authors:  N Jon Shah; Hans Herzog; Christoph Weirich; Lutz Tellmann; Joachim Kaffanke; Liliana Caldeira; Elena Rota Kops; Syed M Qaim; Heinz H Coenen; Hidehiro Iida
Journal:  PLoS One       Date:  2014-04-22       Impact factor: 3.240

  2 in total
  5 in total

1.  Monte Carlo Simulations of the GE Signa PET/MR for Different Radioisotopes.

Authors:  Paulo R R V Caribé; Stefaan Vandenberghe; André Diogo; David Pérez-Benito; Nikos Efthimiou; Charlotte Thyssen; Yves D'Asseler; Michel Koole
Journal:  Front Physiol       Date:  2020-09-15       Impact factor: 4.566

Review 2.  Clinical Utility and Future Applications of PET/CT and PET/CMR in Cardiology.

Authors:  Jonathan A Pan; Michael Salerno
Journal:  Diagnostics (Basel)       Date:  2016-09-02

3.  Quantitative performance and optimal regularization parameter in block sequential regularized expectation maximization reconstructions in clinical 68Ga-PSMA PET/MR.

Authors:  Edwin E G W Ter Voert; Urs J Muehlematter; Gaspar Delso; Daniele A Pizzuto; Julian Müller; Hannes W Nagel; Irene A Burger
Journal:  EJNMMI Res       Date:  2018-07-27       Impact factor: 3.138

4.  Evaluations of the performances of PET and MRI in a simultaneous PET/MRI instrument for pre-clinical imaging.

Authors:  Alyssa C Pollard; Jorge de la Cerda; F William Schuler; Charles V Kingsley; Seth T Gammon; Mark D Pagel
Journal:  EJNMMI Phys       Date:  2022-10-08

5.  Positron annihilation localization by nanoscale magnetization.

Authors:  Yaser H Gholami; Hushan Yuan; Moses Q Wilks; Lee Josephson; Georges El Fakhri; Marc D Normandin; Zdenka Kuncic
Journal:  Sci Rep       Date:  2020-11-20       Impact factor: 4.379

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.