Literature DB >> 27075920

Contrast agent comparison for three-dimensional micro-CT angiography: A cadaveric study.

Mitchell J Kingston1,2, Diana M Perriman1,2, Teresa Neeman3, Paul N Smith1,2, Alexandra L Webb2.   

Abstract

Barium sulfate and lead oxide contrast media are frequently used for cadaver-based angiography studies. These contrast media have not previously been compared to determine which is optimal for the visualisation and measurement of blood vessels. In this study, the lower limb vessels of 16 embalmed Wistar rats, and four sets of cannulae of known diameter, were injected with one of three different contrast agents (barium sulfate and resin, barium sulfate and gelatin, and lead oxide combined with milk powder). All were then scanned using micro-computed tomography (CT) angiography and 3-D reconstructions generated. The number of branching generations of the rat lower limb vessels were counted and compared between the contrast agents using ANOVA. The diameter of the contrast-filled cannulae, were measured and used to calculate the accuracy of the measurements by comparing the bias and variance of the estimates. Intra- and inter-observer reliability were calculated using intra-class correlation coefficients. There was no significant difference (mean difference [MD] 0.05; MD 95% confidence interval [CI] -0.83 to 0.93) between the number of branching generations for barium sulfate-resin and lead oxide-milk powder. Barium sulfate-resin demonstrated less bias and less variance of the estimates (MD 0.03; standard deviation [SD] 1.96 mm) compared to lead oxide-milk powder (MD 0.11; SD 1.96 mm) for measurements of contrast-filled cannulae scanned at high resolution. Barium sulfate-resin proved to be more accurate than lead oxide-milk powder for high resolution micro-CT scans and is preferred due to its non-toxicity. This technique could be applied to any embalmed specimen model.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  angiography; barium sulfate; contrast media; lead oxide; micro-computed tomography

Mesh:

Substances:

Year:  2016        PMID: 27075920     DOI: 10.1002/cmmi.1695

Source DB:  PubMed          Journal:  Contrast Media Mol Imaging        ISSN: 1555-4309            Impact factor:   3.161


  7 in total

Review 1.  Assaying three-dimensional cellular architecture using X-ray tomographic and correlated imaging approaches.

Authors:  Peter O Bayguinov; Max R Fisher; James A J Fitzpatrick
Journal:  J Biol Chem       Date:  2020-09-16       Impact factor: 5.157

2.  Controlled dissolution of freeform 3D printed carbohydrate glass scaffolds in hydrogels using a hydrophobic spray coating.

Authors:  M C Gryka; T J Comi; R A Forsyth; P M Hadley; S Deb; R Bhargava
Journal:  Addit Manuf       Date:  2018-12-27

3.  Iodine-Enhanced Micro-CT Imaging of Soft Tissue on the Example of Peripheral Nerve Regeneration.

Authors:  Patrick Heimel; Nicole Victoria Swiadek; Paul Slezak; Markus Kerbl; Cornelia Schneider; Sylvia Nürnberger; Heinz Redl; Andreas Herbert Teuschl; David Hercher
Journal:  Contrast Media Mol Imaging       Date:  2019-03-27       Impact factor: 3.161

4.  Comparison of Three-Dimensional Micro-CT Angiography of Cervical Spinal Cord between Two Contrast Agents.

Authors:  Yapu Liu; Qi Liu; Zhou Yang; Junyu Lin; Xiuhua Wu; Zucheng Huang; Junhao Liu; Rong Li; Zhiping Huang; Xiaoliang Wu; Qingan Zhu
Journal:  Contrast Media Mol Imaging       Date:  2019-04-11       Impact factor: 3.161

5.  [Anatomy of pisiform blood supply and feasibility of vascularized pisiform transfer for avascular necrosis of lunate based on digital technique].

Authors:  Yujian Xu; Yongqing Xu; Haotian Luo; Xiaoqing He; Xulin Zhang; Wanqiu Zhao; Huan Wu; Libo Yuan
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-05-15

6.  Application of novel targeting nanoparticles contrast agent combined with contrast-enhanced computed tomography during screening for early-phase gastric carcinoma.

Authors:  Kaimin Zhang; Xijian Du; Kaihu Yu; Kaiyu Zhang; Yicheng Zhou
Journal:  Exp Ther Med       Date:  2017-10-30       Impact factor: 2.447

7.  Three-dimensional Intralunate Arteries Visualization with Red Lead (Pb3O4) Angiography.

Authors:  Zi-Run Xiao; Wei-Guang Zhang; Ge Xiong; You-Le Zhang
Journal:  Chin Med J (Engl)       Date:  2017-11-05       Impact factor: 2.628

  7 in total